                                              PMS5003T PM2.5 particulate matter concentration sensor

 

Here are the detailed specification parameters of the PMS5003T particulate matter concentration and temperature-humidity sensor:

 

Measurement Parameters

  • Particulate Matter Measurement Range: 0.3 to 10 microns, with a counting efficiency of 50% for 0.3-micron particles and ≥98% for particles ≥0.5 microns.
  • Particulate Matter Mass Concentration Resolution: 1 μg/m³. The effective range for PM2.5 mass concentration is 0–500 μg/m³, and the maximum range is ≥1000 μg/m³.
  • Particulate Matter Mass Concentration Consistency: When PM2.5 concentration is 100–500 μg/m³, the error is within ±10%; within 0–100 μg/m³, the error is ≤±10 μg/m³.
  • Temperature Measurement Range: 0–99°C, with a resolution of 0.1°C and accuracy of ±0.5°C.
  • Humidity Measurement Range: 0–99%, with a resolution of 0.1% and accuracy of ±2%.

 

Electrical Parameters

  • Operating Voltage: Typical value 5.0V, minimum 4.5V, maximum 5.5V.
  • Operating Current: ≤100 mA, standby current ≤200 μA.
  • Data Interface Level: Low level L<0.8V@3.3V, high level H>2.7V@3.3V.

 

Performance Parameters

  • Response Time: Single response time <1 second, total response time ≤10 seconds.
  • Mean Time Between Failures (MTBF): ≥3 years.

 

Physical Parameters

  • Dimensions: 50×38×21 mm.
  • Weight: No official data available, expected to be lightweight for easy integration and installation.

 

Output Parameters

  • Output Modes:
    • Active Output: The default state after power-on, where serial data is actively sent to the host at intervals of 200–800 ms. The higher the particulate matter concentration in the air, the shorter the interval. Active output includes:
      • Stable Mode: When concentration changes are small, the same set of values is output three times, with an actual data update cycle of ~2 seconds.
      • Fast Mode: When concentration changes are large, new values are output each time, with an actual data update cycle of 200–800 ms.
    • Passive Output: No active data sending; data is read upon host request.
  • Data Format: Output via a universal digital interface with default baud rate 9600 bps, no parity bit, 1 stop bit, and a protocol total length of 32 bytes.

 

Operating Voltage Typical value 5.0V, minimum 4.5V, maximum 5.5V.
Operating Current ≤100 mA, standby current ≤200 μA.
Mean Time Between Failures (MTBF) ≥3 years.
Dimensions 50×38×21 mm

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShenzhenYijiajie Electronic Co., Ltd.
Location Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Contact Person Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.