ShenzhenYijiajie Electronic Co., Ltd.
                                                                                                           
Verified Supplier
20 Years
Since 2006
Menu

MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process

Price Negotiable
Price: Negotiable
MOQ: 1PCS
Delivery Time: 5-8 work days
Brand: IRS4
Product Description

 

                             MPn-4C CH4 Methane Flammable Gas Sensor For Manufacturing Process 

 

      Target Gas: CH4, methane, natural gas, marsh gas

  • Detection Range: 300 - 10000 ppm (methane, natural gas)
  • Detection Principle: Semiconductor
  • Characteristics: High sensitivity to CH4 gas, excellent anti - interference ability, excellent stability
  • Manufacturing Process: Adopts a multi - layer thick film manufacturing process, which integrates a heating electrode, a measuring electrode and a metal oxide semiconductor gas - sensitive layer on an Al2O3 ceramic substrate, and encapsulates it in a metal housing.
  • Working Principle: When the detected gas is present in the ambient air, the conductivity of the sensor will change, and the higher the concentration of the gas, the higher the conductivity of the sensor. This change in conductivity can be converted into an output signal corresponding to the gas concentration using a simple circuit.
  • Application: Widely used in combustible gas leak monitoring devices, fire/safety detection systems for home, factory and commercial use; flammable gas leak alarm, gas leak detector, etc.

 

Model MPn - 4C
Target Gas CH4, Natural Gas, Marsh Gas
Detection Range 300 - 10000 ppm (methane, natural gas)
Detection Principle Semiconductor
Standard Circuit Conditions Loop voltage VC ≤ 24 V DC
Heater voltage VH 5 V ± 0.1 V AC or DC
Load resistance RL adjustable
Heater Consumption PH ≤ 350 mW
Sensitive Resistance RS 1 kΩ - 20 kΩ (in 5000 ppm CH4)
Sensitivity S = RS (in air) / RS (5000 ppm CH4) ≥ 8
Concentration Slope α ≤ 0.6 (R5000 ppm / R1000 ppm CH4)
Standard Test Conditions Temperature 20 ℃ ± 2 ℃; Humidity 55 % ± 5 % RH
Standard Test Circuit VC: 5 V ± 0.1 V; VH: 5 V ± 0.1 V
Preheat Time Not less than 48 hours
O2 Content 21 % (not less than 18 %)
Lifespan 10 years
Sensor Type Flat - surfaced
Standard Encapsulation Metal cap

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ShenzhenYijiajie Electronic Co., Ltd.
Location Room 3306AB 33rd Floor, SEG Plaza,Huaqiang North Road, Futian District, Shenzhen Guangdong Province 518028
Contact Person Xu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.