Portable Medical Fingertip Pulse Oximeter Blood Oxygen Monitor 35.5g

Price Negotiable
Price: $3.35~3.95/pc
MOQ: 100pcs
Delivery Time: 1-4 working days
Brand: Responsafe
Product Description

Portable LED Finger Pulse Oximeter New Design Export Only Blood Oxygen Monitor

 

 

Fingertip Pulse Oximeter Operation:

1) SpO2 value display
2) Pulse rate value display, bar graph display
3) Pulse waveform display
4) PI value display
5) The display mode can be changed
6) Low-voltage indication: low-voltage indicator appears before working abnormally which is due to low-voltage
7) Pulse sound indication and over limit indication

 

 

Fingertip Pulse Oximeter Parameters

 

Product Name LED Display Private Model Pulse Oximeter
Measurement Range SpO2: 35%-99%
Pulse Rate(PR): 30~240BPM
Measurement Time ≤20S
Resolution Spo2: ±1%
Pulse Rate(PR): ±1BPM
Accuracy ±1%(90%-99%) ; ±2% (70%-89%); unspecified(≤70%) for Spo2
Low Perfusion ≤0.4%
Power Two of 1.5(AAA Size) alkaline batteries
Power Consumption <30mA
Automatic Power-off The product will automatically power off when no signals for 8s.
Operation Environment Operation temperature: 5℃~40℃
Humidity: 30%~90%
Air pressure: 59KPa~107.4KPa
Dimension 58*32*22mm
Net Weight 27.5g (Batteries Not Included)
Package 1 Unit/Box, 200 Boxes/Ctn
Carton Size 40*28*31cm
G.W./Carton 8.1kg
Certificates CE
Warranty 6 months

 

 

Fingertip Pulse Oximeter Features

 

  • Display Mode:0.96" LED display

  • Screen Resolution:128*64

  • SpO2 Measuring Range:0%~100%, (the resolution is 1%), accuracy:70%~100%:±2% ,Below 70% unspecified.

  • PR Measuring Range:30 bpm~250 bpm, (the resolution is 1 bpm), accuracy:±2 bpm or ±2% (select larger)

  • PI Measuring Range: 0 %~ 20%, accuracy:When the PI measure range is 1%~20%,the permission of absolute error is ±1%. When the PI measure range is 0%~0.9%,the permission of absolute error is ±0.2%

  • Measurement Performance in Weak Filling Condition:SpO2 and pulse rate can be shown correctly when pulse-filling ratio is 0.4%. SpO2 error is ±4%, pulse rate error is ±2 bpm or ±2% (select larger).

  • Resistance to surrounding light: The deviation between the value measured in the condition of man-made light or indoor natural light and that of darkroom is less than ±1%

  • Power Consumption:less than 80 mA

  • Voltage: DC 2.6 V - 3.6 V

  • Power Supply:1.5 V (AAA size) alkaline batteries × 2

  • Safety Type:Interior Battery,BF Type

     

 

About Us

 

We're generally specialized in 5 fields:

 

1. Diabetes Care: Lancet, Lancing Device, Insulin Pen Needle, Insulin Syringe, Safety Pen Needle, Blood Glucose Meter and Test Strip etc.;

2. Household & Hospital Medical Equipment: Thermometer, Oximeter, Nebulizer, Blood Pressure Monitor and Oxygen Concentrator etc.;

3. Wound Dressing: Wound Dressing Patch, Fixation Retention Roll, Medical Tape, Various Bandage and Pain Relief Patch etc;

4. Surgical Device: Surgical Blade, Disposable Scalpel and Surgical Suture etc;

5: PPE: Masks, Protective Coverall, Surgical Gown, Safety Goggle, Medical Examination Glove and Surgical Glove etc.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Henan Responsafe Medical Instrument Co., Ltd
Location ROOM 1101,CROSS-BORDER BUILDING,China Henan xinxiang
Contact Person Annie

Request A Quote

Please check your email address.
Your message must be at least 20 characters.