Shandong Gelon Lib Co., Ltd
                                                                                                           
Verified Supplier
19 Years
Since 2007
Menu

5V10mA 5V20mA 5V50mA Battery Testing Equipment Coin Cell Research

Price Negotiable
MOQ: 1 set
Delivery Time: 15-20 works day
Brand: GELON
Product Description

Battery Tester 5V10mA 5V20mA 5V50mA Coin Cell Research And Development Battery Testing Lab

 

Technical Parameter​:

5V10mA Battery Testing System
Model: GN- 5 V 10 mA Battery Testing System SN: 4008T -5V10mA - 164
Items Values
Input AC AC 220V/110V ±10% / 50Hz
Input power 709 mW
Resolution AD:16bit;DA:16bit
Input impedance ≥1G Ω

 

 

Voltage

CV output range 25mV~5V
Min discharge voltage -5V
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS

 

 

Current

Output range/channel Range1: 5μA-1mA; Range2: 1mA-5mA; Range3: 5mA-10mA;
Accuracy ± 0.05% of FS
CV cut-off current Range1:2μA;Range2:0.01mA;Range3:0.02mA
Stability ± 0.05% of FS

 

Power

Output power/channel 0.05 W
Stability ± 0.1% of FS

 

Time

Current response time <500μs (10%FS~90%FS)
Working step time ≤(365*24)h/step Time format-00:00:00.000(h,m,s,ms)

 

 

Data record

 

Data record conditions

Min data record interval:100ms
Min voltage change:10mV
Min current change:2μA; 0.01mA; 0.02mA
Frequency 10Hz

 

Charge

Charge modes CC,CV,CCCV,CP
Cut-off condition Voltage,Current,Time,Capacity,-△V

 

Discharge

Discharge modes CC,CP,CR,CV
Cut-off condition Voltage,Current,Time,Capacity

 

 

 

Pulse

Charge CC,CP
Discharge CC,CP
Min pulse width 500ms
Pulse counts Up to 32
Chg and Dis chg switch Supported
Cut-off condition Voltage,Time
DCIR Supported

 

Cycle

Max cycles 65535
Max steps 254
Cycle nest 3

 

 

Protection

 

 

Safety protection

  • Power-off data protection
  • Off-line operation mode
  • User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.

 

5V20mA Battery Testing System
Model: GN- 5 V 20 mA Battery Testing System SN: 4008T -5V20mA -164
Items Values
Input AC AC 220V/110V ±10% / 50Hz
Input power 25 W
Resolution AD:16bit; DA: 16bit
Input impedance ≥1G Ω

 

 

Voltage

CV output range 25mV~5V
Min discharge voltage -5V
Accuracy ± 0.05% FS
Stability ± 0.05% FS

 

 

Current

Output range/channel Range1: 5μA-1mA; Range2: 1mA-10mA; Range3: 10mA-20mA
Accuracy ± 0.05% FS
CV cut-off current Range1: 2μA; Range2: 20μA; Range3: 40μA
Stability ± 0.05% FS

 

Power

Output power/channel 0.1 W
Stability ± 0.1% of FS

 

Time

Current response time <500μs (10%FS~90%FS)
Working step time ≤(365*24)h/step Time format-00:00:00.000(h, m, s, ms)

 

 

Data record

Data record conditions Min data record interval:100ms
Min voltage change: 10mV
Min current change: 2μA; 20μA; 40μA
Frequency 10Hz

 

Charge

Charge modes CC, CV, CCCV, CP
Cut-off condition Voltage, Current, Time, Capacity, Energy, -△V

 

Discharge

Discharge modes CC, CV, CCCV, CP, CR
Cut-off condition Voltage, Current, Time, Capacity, Energy

 

 

 

Pulse

Charge CC, CP
Discharge CC, CP
Min pulse width 500ms
Pulse counts Up to 32
Chg and Dschg switch Supported
Cut-off condition Voltage, Time
DCIR Supported

 

Cycle

Max cycles 65535
Max steps 254
Cycle nest 3

 

 

Protection

 

 

Safety protection

● Power-failure data protection
● Offline operation mode
● User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.

 

 

5V50mA Battery Testing System
Model: GN- 5 V 50 mA Battery Testing System SN: 4008T -5V50mA - 164
Items Values
Input AC AC 220V/110V ±10% / 50Hz
Input power 25 W
Resolution AD:16bit;DA:16bit
Input impedance ≥1G Ω

 

 

Voltage

CV output range 25mV~5V
Min discharge voltage -5V
Accuracy ± 0.05% of FS
Stability ± 0.05% of FS

 

 

Current

Output range/channel Range1: 5μA-1mA; Range2: 1mA-25mA; Range3: 25mA-50mA
Accuracy ± 0.05% of FS
CV cut-off current Range1: 2μA; Range2: 50μA; Range3: 100μA
Stability ± 0.05% of FS

 

Power

Output power/channel 0.25 W
Stability ± 0.1% of FS

 

Time

Current response time <500μs (10%FS~90%FS)
Working step time ≤(365*24)h/step Time format-00:00:00.000(h,m,s,ms)

 

 

Data record

 

Data record conditions

Min data record interval:100ms
Min voltage change:10mV
Min current change:2μA; 50μA; 100μA
Frequency 10Hz

 

Charge

Charge modes CC,CV,CCCV,CP
Cut-off condition Voltage,Current,Time,Capacity,-△V

 

Discharge

Discharge modes CC,CP,CR,CV
Cut-off condition Voltage,Current,Time,Capacity

 

 

 

Pulse

Charge CC,CP
Discharge CC,CP
Min pulse width 500ms
Pulse counts Up to 32
Chg and Dis-chg switch Supported
Cut-off condition Voltage,Time
DCIR Supported

 

Cycle

Max cycles 65535
Max steps 254
Cycle nest 3

 

 

Protection

 

 

Safety protection

  • Power-off data protection
  • Off-line operation mode
  • User-defined protection conditions, such as upper and lower limited current/voltage, delay time, temperature, etc.

 

 

 

 

We supply:
1.Full set of lithium battery materials,including:
LiFePO4,LiMn2O4,LTO,LiNiMnCoO2(NMC),LiCoO2,Graphite(MCMB)and Other Cathode&Anode Battery Materials;Aluminum foil,Copper foils,Battery separator,etc.

2.Full set of lithium battery equipment,for example:
mixing machine --coating machine--vacuum oven--rolling machine--welding machine--slitting / cutiing machine --winding machine--sealed machine,etc.

3.Full set of lithium battery technology.
we can design the laboratory and production line according to customer's request.
Any more info, pls kindly contact: mavis@libgroup.net

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Shandong Gelon Lib Co., Ltd
Location CN,Shandong,Linyi,Room 1606, Building 1, Jinding International Plaza, Junction Of Hongqi Road And Yimeng Road, Lanshan District
Contact Person Ekain Zhang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.