OK-EP60VF Ultrapure Water Machine 60L/h with UV Sterilization 18.25MΩ Resistivity for Laboratory Analysis
Price:
USD2388-USD2688
MOQ:
1set
Delivery Time:
5-8 working days
Brand:
Okay Energy
Product Description
Chemical Analysis Ultrapure Water Machine with UV Sterilization
Product Overview
This CE-certified ultrapure water system is designed for chemical analysis laboratories and microbiological applications. The system features UV sterilization and ultrafiltration technology to remove endotoxins, DNase, and Rnase, delivering water with extremely low total organic carbon (TOC) levels below 50 ppb.
Technical Specifications
| Parameter | Specification |
|---|---|
| Model | OK-EP60VF |
| AC Voltage | 110/220V, 50/60Hz |
| Flow Rate | 1.5-2L/min |
| Output Capacity | 60L/h |
| Type 1 Ultra-pure Water Quality | Resistivity: 18.25MΩ/cm@25℃, TOC: <5ppb, Bacteria: <1CFU/ml |
| Type 2 Pure Water Quality | Conductivity: 2-10μs/cm@25℃ |
| Dimensions | 500×450×750 mm |
| Weight | 70 kg |
Advanced Filtration Technology
- UV sterilization lamp eliminates bacterial spores
- Ultrafiltration system for pyrogen removal
- Multi-stage purification: PP filter, activated carbon, reverse osmosis membrane, and ion exchange column
Application Areas
- Molecular biology and life science research
- Gene research and tissue culture
- Bioengineering and test tube baby procedures
- Animal and plant cell culture
- DNA and monoclonal antibody research
- Chromatography and mass spectrometry
- UV-visible spectrophotometry
- Microbiology and chemical analysis
Key Features
- Economical design with easy installation
- Produces 2L/min of ASTM Type I water
- Dual output for both pure water and ultrapure water
- High resistivity up to 18.25 MΩ/cm
- Ultra-low TOC levels below 5 ppb
- Compatible with tap water or pre-treated sources
- Real-time resistivity monitoring
- Intuitive prompts, animations, and alert system
Maintenance Guidelines
PP filter and activated carbon filter: Replace every 6 months
Ion exchange column: Replace when resistivity ≤ 10MΩ.CM
Standard consumable cartridge includes all essential filtration components
Note: The conductivity of RO water is affected by inlet water conductivity. TOC values are influenced by inlet conditions and sampling environment. System performance optimized for inlet water TDS ≤200mg/L.