MTP MPO Fiber Optic Patch Cord High Density 12F 24F 48F 72F 96F 144F
Product Overview
Application
1. Data communication network.
2. Optical System Access network.
3. Storage area networking fiber channel.
4. High density architectures.
Features
1. 100% pre-terminated and tested in factory to ensure transfer performance.
2. Rapid configuration and networking, reduce installation time.
3. Supports 40G and 100G network applications.
4. Cable Jacket material: LSZH, OFNR, OFNP available.
5. Supports up to 12F, 24F, 48F, 72F, 96F, 144F, customized products are available
Patch cord versions
| Jumper tolerance requirement | |
| Overall length (L) (M) | length of tolerance(CM) |
| 0<L≤20 | +10/-0 |
| 20<L≤40 | +15/-0 |
| L>40 | +0.5%L/-0 |
Cable Structure
Cable Parameters
| Fiber account | OD(mm) | Nominal Weight (kg/km) | Max.tensile Strength(N) | Max.Crush Resistance (N/100mm) | Min.Bending Radius(mm) |
|||
| Short-term | Long-term | Short-term | Long-term | Dynamic | Static | |||
| 8 | 3.0±0.15 | 6.8 | 180 | 90 | 500 | 150 | 20D | 10D |
| 12 | 3.0±0.15 | 7.0 | 180 | 90 | 500 | 150 | 20D | 10D |
MPO&MTP Optical Characteristics
| Item | Parameter | Reference | ||||
| Single mode | Multimode | |||||
| Standard | Elite | Standard | Elite | |||
| Insertion loss | Typical≤0.30dB Max≤0.75dB |
Typical≤0.15dB Max≤0.35dB |
Typical≤0.50dB Max≤0.25dB |
Typical≤0.10dB Max≤0.35dB |
IEC 61300-3-34 | |
| Return loss | ≥ 50dB (PC) ≥ 60dB (APC) |
≥ 55dB (PC) ≥ 65dB (APC) |
≥30dB(PC) | ≥30dB(PC) | IEC 61300-3-6 | |
LC/SC/FC/ST Optical Characteristics
| Item | Parameter | Reference | |
| Single mode | Multimode | ||
| Insertion loss | Typical value≤0.15dB;Maximum≤0.30 | Typical value≤0.15dB;Maximum≤0.30 | IEC 61300-3-34 |
| Return loss | ≥ 60dB (APC); ≥ 50dB (UPC) | ≥30dB (UPC) | IEC 61300-3-6 |
LC/SC/FC/ST End-Face Geometry
| Item | UPC (Ref: IEC 61755-3-1) | APC (Ref: IEC 61755-3-2) |
| Radius of curvature (mm) | 10 to 25 | 5 to 12 |
| Fiber height (nm) | -100 to 100 | -100 to 100 |
| Apex offset (μm) | 0 to 50 | 0 to 50 |
| APC angle (°) | / | 8° ±0.2° |
| Key error (°) | / | 0.2° max |
MPO&MTP End-Face Geometry
| Ferrule parameter | IEC-61300--3-30 | |||
| Minimum | Maximum | |||
| ROC | ROC-X: | 2000mm | ∞ | |
| ROC-Y: | 50mm | ∞ | ||
| Angle | Angle-X: | -0.2° | 0.2° | |
| Angle-Y: | PC | -0.2° | 0.2° | |
| APC | 7.85° | 8.15° | ||
| Fiber Hight: | 1000nm | 3500nm | ||
| Max.DH.All: | -300nm | 300nm | ||
| DH.Adj: | -300nm | 300nm | ||
| DH.Ave Fiber: | -300nm | 300nm | ||
| Core Dip: | MM | -200nm | 300nm | |
| SM | N/A | N/A | ||
| Ferrule height | 7.9mm | 8.05mm | ||
End-Face Qualty (SM)
| Zone | Range ((μm) | Scratches | Defects | Reference |
| A: Core | 0 to 25 | None | None | IEC 61300-3-35:2015 |
| B: Cladding | 25 to 115 | None | None | |
| C: Adhesive | 115 to 135 | None | None | |
| D: Contact | 135 to 250 | None | None | |
| E: Rest of ferrule | None | None | ||
End-Face Qualty (MM)
| Zone | Range ((μm) | Scratches | Defects | Reference |
| A: Core | 0 to 65 | None | None | IEC 61300-3-35:2015 |
| B: Cladding | 65 to 115 | None | None | |
| C: Adhesive | 115 to 135 | None | None | |
| D: Contact | 135 to 250 | None | None | |
| E: Rest of ferrule | None | None | ||
Mechanical Characteristics
| Test | Conditions | Reference |
| Endurance | 500 matings | IEC 61300-2-2 |
| Vibration | Frequency: 10 to 55Hz, Amplitude: 0.75mm | IEC 61300-2-1 |
| Cable retention | 400N (main cable); 50N (connector part) | IEC 61300-2-4 |
| Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
| Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
| Strength of coupling mechanism | 80N for 2 to 3mm cable | IEC 61300-2-6 |
| Cable torsion | 15N for 2 to 3mm cable | IEC 61300-2-5 |
| Fall | 10 drops, 1m drop height | IEC 61300-2-12 |
| Static lateral load | 1N for 1h (main cable); 0.2N for 5min (ranch part) | IEC 61300-2-42 |
| Cold | -25°C, 96h duration | IEC 61300-2-17 |
| Dry heat | +70°C, 96h duration | IEC 61300-2-18 |
| Change of temperature | -25°C to +70°C, 12 cycles | IEC 61300-2-22 |
| Humidity | +40°C at 93%, 96h duration | IEC 61300-2-19 |