Lincmos Precision Integrated Circuit Chip Dual Operational Amplifiers Tlc272cpwr

Price Negotiable
Price: Negotiate
MOQ: 10pcs
Delivery Time: 1 day
Product Description

 
TLC272, TLC272A, TLC272B, TLC272Y, TLC277
LinCMOSTM PRECISION DUAL OPERATIONAL AMPLIFIERS
 
*Trimmed Offset Voltage:
       TLC277 . . . 500 µV Max at 25°C, VDD = 5 V
 
*Input Offset Voltage Drift ...Typically
       0.1 µV/Month, Including the First 30 Days
 
*Wide Range of Supply Voltages Over
    Specified Temperature Range:
              0°C to 70°C . . . 3 V to 16 V
              –40°C to 85°C . . . 4 V to 16 V
              –55°C to 125°C . . . 4 V to 16 V
 
*Single-Supply Operation
 
*Common-Mode Input Voltage Range
    Extends Below the Negative Rail (C-Suffix, I-Suffix types)
 
*Low Noise ...Typically 25 nV/√Hz at f = 1 kHz
 
*Output Voltage Range Includes Negative Rail
 
*High Input impedance . . . 1012 Ω Typ
 
*ESD-Protection Circuitry
 
*Small-Outline Package Option Also Available in Tape and Reel
 
*Designed-In Latch-Up Immunity
 
 
 
 
description
 

The TLC272 and TLC277 precision dual operational amplifiers combine a wide range of input offset voltage grades with low offset voltage drift, high input impedance, low noise, and speeds approaching those of general-purpose BiFET devices.
 
These devices use Texas Instruments silicongate LinCMOSTM technology, which provides offset voltage stability far exceeding the stability available with conventional metal-gate processes.
 
The extremely high input impedance, low bias currents, and high slew rates make these costeffective devices ideal for applications previously reserved for BiFET and NFET products. Four offset voltage grades are available (C-suffix and I-suffix types), ranging from the low-cost TLC272 (10 mV) to the high-precision TLC277 (500 µV). These advantages, in combination with good common-mode rejection and supply voltage rejection, make these devices a good choice for new state-of-the-art designs as well as for upgrading existing designs.
 
 
 
 
absolute maximum ratings over operating free-air temperature range (unless otherwise noted)†
 
Supply voltage, VDD (see Note 1) . . . . . . . . . . . . . . . . . . . . .. . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . .18V 
Differential input voltage, VID (see Note 2) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±VDD
Input voltage range, VI (any input) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . –0.3 V to VDD
Input current, II . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  . ±5 mA
output current, IO (each output) . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . ±30 mA
Total current into VDD . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 mA
Total current out of GND . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . 45 mA
Duration of short-circuit current at (or below) 25°C (see Note 3)  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .unlimited
Continuous total dissipation  . . . . . . . . . . . . . .. . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .See Dissipation Rating Table Operating free-air temperature, TA: C suffix  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  0 °C to 70°C
                                                           I suffix  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  –40°C to 85°C
                                                           M suffix   . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  –55°C to 125°C
Storage temperature range . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  –65°C to 150°C
Case temperature for 60 seconds: FK package  . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . . .  260°C
Lead temperature 1,6 mm (1/16 inch) from case for 10 seconds: D, P, or PW package  . . . . . . . .. . . . . . .  260°C
Lead temperature 1,6 mm (1/16 inch) from case for 60 seconds: JG package  . . . . . . . . . . . . . . . . . . . . . .  300°C
 
† Stresses beyond those listed under “absolute maximum ratings” may cause permanent damage to the device. These are stress ratings only, and functional operation of the device at these or any other conditions beyond those indicated under “recommended operating conditions” is not implied. Exposure to absolute-maximum-rated conditions for extended periods may affect device reliability.
NOTES: 1. All voltage values, except differential voltages, are with respect to network ground.
              2. Differential voltages are at IN+ with respect to IN–.
              3. The output may be shorted to either supply. Temperature and/or supply voltages must be limited to
                   ensure that the maximum dissipation rating is not exceeded (see application section).
 
 
recommended operating conditions

     C SUFFIX         I SUFFIX        M SUFFIX   UNIT
  MIN     MAX   MIN           MAX   MIN           MAX
   Supply voltage, VDD     3         16     4               16     4               16      V

  Common-mode input  
  voltage, VIC

  VDD = 5 V   –0.2      3.5   –0.2            3.5     0               3.5      V
  VDD = 10 V   –0.2      8.5   –0.2            8.5     0               8.5
  Operating free-air temperature, TA     0         70    –40             85    –55            125      °C

 
 
 
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company ChongMing Group (HK) Int'l Co., Ltd
Location Room 1204, DingCheng International Building, 518028 Futian District, SHENZHEN, CN
Contact Person Doris Guo

Request A Quote

Please check your email address.
Your message must be at least 20 characters.