Working Principle

 

Lobe pump is self-priming, valveless positive displacement pump. Through the two parallel shafts in the synchronous gear to driven the rotor synchronous operation, chamber form a vacuum between the rotor vanes and casting surrounding, so that the medium was inhaled, then displaced through the discharge-side. Pump operating direction can be reversed by changing the direction of rotor rotation, to be a two-way pump for reversing operation.

 

Specifications:

 

Description Rotary Lobe Pumps
Rotor  tri-lobe SS 316
Seal Electric sealing sensor / Double-acting mechanical seal
Axial and radial casing protection Wear-resistant steel / Hardened steel / Stainless steel / SIC
Drive Variable geared motor / Combustion motor / Hydraulic motor
Pump Full of stainless steel
Gear Helical geared motor / Manual adjustable speed motor
Speed 10 - 600 rpm
Custom printing Acceptable

 

Parameter of AP 80

 

Drive Weight Dimensions
KW KG L / mm H / mm
3 190 1158 394
4 202 1178 419
5.5 223 1258 454
7.5 236 1298 454
11 291 1380 509
15 354 1425 509

 

Design 1 | Short, s traight pipe connectors with connection flange and gasket, in mm / inches approx.

 

AP 80 DN 50 mm DN 65 mm DN 80 mm DN 100 mm DN 125 mm

 

Solution guidance

 

Problem Possible Cause Remedy

 

 

 

 

 

Motor Operational but No Fluid Delivery

Direction of Rotation Check direction of rotation is in line with arrow on casing and nameplate
Air pocket in suction line Ensure suction line filled with fluid, pipework slopes upwards, no kinks in suction line and pipework is as straight as possible.
Relief Valve Failure Clean Relief Valve. Check pressure setting. Recalibrate
Check Valve Jammed Clean check valve. Check operation
Air Ingress through Seal Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary.

 

 

 

 

 

 

 

 

Insufficient Capacity

Relief Valve Opening or Jammed Check relief valve settings. Recalibrate. Check and clean as a plug may have formed or solid entered jamming open.
Air Ingress Check seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary.
Low NPSH Shorten and enlarge suction line diameter. Deepen suction pipe, increase tank contents, reduce pump speed and check fluid viscosity against pump design
Pump Worn Check internal lobe spacing. Replace lobes
Check Valve Jammed Clean check valve. Check operation

 

 

 

 

Pump Noisy

Pump Cavitating Increase pipework diameter. Reduce suction head. Check fluid viscosity. Clean filters. Reduce pump speed. Increase fluid level in tank.
Lobe / Rotor Damage Check lobes and replace if necessary
Misalignment Realign Pump. Check coupling and rubber
Vibration in safety valve Increase pressure setting or replace

 

 

Advantage

 

• Low shear/Pulse free operation

• Excellent for oil/water and high viscosity liquid.

• Ability to pump at constant pressure at different flow rates

• Self-priming to 9.5 meters

• Forward and reverse pumping operation

• Space-saving compact design

• 10 to 1 turn down capability and reverse capability

• Run dry ability for a period of time

 

 

Quality inspection photos

 

 

 

 


 
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Accuvon (Guangzhou) Pumps Co., Ltd
Location No. 98, YanshaRoad, Nanpu, Luopu street, Panyu District, Guangzhou
Contact Person Demi Liu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.