Professional Chemical Grade Anti-Corrosion Hot Durable Rotor Pump
 
Operating Principles:
 
When pump lobes rotates, the space between 2 lobes increase, it will create a partial vacuum to transfer fluid into pump chamber, The pump shaft keeps turning, lobes will continue to create space to delivery fluid, the tolerance between lobes and chamber ensure the space is suitable to filled. When the pump chamber is fully filled, the fluid will be transfer to outlet.
 
Specifications:
 

DescriptionRotary Lobe Pumps
RotorPlastic / tri-lobe with screw profile / PTFE
SealElectric sealing sensor / Double-acting mechanical seal
Axial and radial casing protectionWear-resistant steel / Hardened steel / Stainless steel / SIC
DriveVariable geared motor / Combustion motor / Hydraulic motor
PumpFull of stainless steel
GearHelical geared motor / Manual adjustable speed motor
Speed10 - 600 rpm
Custom printingAcceptable

 
Parameter of AP 80
 

DriveWeightDimensions
KWKGL / mmH / mm
31901158394
42021178419
5.52231258454
7.52361298454
112911380509
153541425509

 
Design 1 | Short, s traight pipe connectors with connection flange and gasket, in mm / inches approx.
 

AP 80DN 50 mmDN 65 mmDN 80 mmDN 100 mmDN 125 mm

 
Solution guidance
 

ProblemPossible CauseRemedy

 
 
 
 
 
Motor Operational but No Fluid Delivery

Direction of RotationCheck direction of rotation is in line with arrow on casing and nameplate
Air pocket in suction lineEnsure suction line filled with fluid, pipework slopes upwards, no kinks in suction line and pipework is as straight as possible.
Relief Valve FailureClean Relief Valve. Check pressure setting. Recalibrate
Check Valve JammedClean check valve. Check operation
Air Ingress through SealCheck seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary.

 
 
 
 
 
 
 
 
Insufficient Capacity

Relief Valve Opening or JammedCheck relief valve settings. Recalibrate. Check and clean as a plug may have formed or solid entered jamming open.
Air IngressCheck seals for air ingress, all pipework, and connected gaskets. Check pump O Rings. Replace pump seal if necessary.
Low NPSHShorten and enlarge suction line diameter. Deepen suction pipe, increase tank contents, reduce pump speed and check fluid viscosity against pump design
Pump WornCheck internal lobe spacing. Replace lobes
Check Valve JammedClean check valve. Check operation

 
 
 
 
Pump Noisy

Pump CavitatingIncrease pipework diameter. Reduce suction head. Check fluid viscosity. Clean filters. Reduce pump speed. Increase fluid level in tank.
Lobe / Rotor DamageCheck lobes and replace if necessary
MisalignmentRealign Pump. Check coupling and rubber
Vibration in safety valveIncrease pressure setting or replace

 
 
Structure features
The pump cavity design is so simple. All models of pumps retain simple design styles. The fast -opening pump cover is opened to provide guarantee for user maintenance personnel without disassembling the pipeline. The driver can guarantee online repair. Greatly reduced the stop time. Before and after, the upper and lower wear -resistant internal lining design, comprehensively ensure the non -wear of the pump shell and ensure long -term durability. Such a simple maintenance characteristics reduce the operating cost of the entire life cycle of the equipment.

 

 

Quality inspection photos

 

 

 

 


 
 
 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Accuvon (Guangzhou) Pumps Co., Ltd
Location No. 98, YanshaRoad, Nanpu, Luopu street, Panyu District, Guangzhou
Contact Person Demi Liu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.