1.25G DWDM SFP Transceiver C17 C61 120km LC Simplex Connector
1.25Gbps DWDM C17~C61 120km SFP Optical Transceiver Module
Ordering information
| Part Number | Product Description |
| S-SD1GDWLA2-CD-xx | SFP,DWDM 1.25Gbps,1510nm~1610nm, SM, LC,120km, 0ºC~+70ºC, With DDM |
| XX=17~61 (ITU Channel C-band) 62~16(ITU Channel L-band) | |
Description
Springtek DWDM SFP Transceiver exhibits excellent wavelength stability, supporting operation at 100 GHz channel, cost effective module. It is designed for DWDM SONET/ SDH, Gigabit Ethernet and Fiber- Channel applications.
The transceiver consists of two sections: The transmitter section incorporates a colded DFB laser. And the receiver section consists of an APD photodiode integrated with a TIA.Springtek DWDM SFP modules satisfy class I laser safety requirements.
DWDM SFP transceiver provides an enhanced monitoring interface, which allows real-time access to device operating parameters such as transceiver temperature, laser bias current, transmitted optical power, received optical power and transceiver supply voltage, laser temperature and TEC current.
Features
- Wavelength selectable to C-band and L-band ITU-T grid wavelengths
-
1.25Gbps operation
-
Suitable for use in 100GHz channel spacing DWDM systems
-
DWDM DFB and APD photodetector for 120km trans-mission
-
Compliant with DWDM SFP MSA with duplex LC receptacle
-
Digital Diagnostic Monitoring
-
Cold Start up Wavelength Compliance
-
Operating case temperature:0 to +70°C
-
RoHS compliant (lead free)
Applications
- SFP Transceivers for DWDM SONET/ SDH
-
Ethernet IEEE 802.3ae
-
Fiber Channel
Absolute Maximum Ratings
| Parameter | Symbol | Min | Typ | Max | Unit |
| Power Supply Voltage | Vcc | -0.3 | 4 | V | |
| Storage Temperature Range | Ts | -40 | 85 | °C | |
| Relative Humidity - Storage | RHS | 0 | 95 | % | |
| Relative Humidity - Operating | RHO | 0 | 85 | % |
Recommended Operating Conditions
| Parameter | Symbol | Min | Typ | Max | Unit |
| Case Operating Temperature Range | Tc | -5 | - | 70 | °C |
| Power Supply Voltage | Vcc | 3.14 | 3.3 | 3.47 | V |
| Supply Current | Icc | - | - | 380 | mA |
Transmitter Specifications – Optical
| Parameter | Symbol | Min | Typical | Max | Unit |
| Data Rate Multirate | Mra | 155 | 1250 | 2667 | Mbps |
| Center Wavelength (SOL)△ | lc | lc -25 | lc | lc +25 | pm |
| Center Wavelength (EOL)▲ | lc | lc -100 | lc | lc+100 | pm |
| Optical Transmit Power | Po | 0 | - | 5 | dBm |
| Side Mode Suppression Ratio | SMSR | 30 | - | - | dB |
| Optical Transmit Power (disabled) | PTX_DISABLE | - | - | -40 | dBm |
| Extinction Ratio | ER | 8.2 | - | dB | |
| Channel Spacing | ∆f | - | 100 | - | GHz |
| Jitter Generation | TJP-P | - | - | 70 | mUI |
| Spectral Width (-20dB) | Dl20 | - | 0.1 | 0.3 | nm |
| Eye Mask | Compliant with Bell core GR-253-CORE & ITU G.957 for SONET/SDH and with IEEE 802.3ae for Ethernet and Fibre Channel | ||||
Transmitter Specifications – Electrical
| Parameter | Symbol | Min | Typical | Max | Unit |
| Supply Voltage | VccTX | 3.13 | 3.3 | 3.47 | V |
| PECL/CML Input | VtxDIFF | 500 | - | 1600 | mV |
| Input Rise/Fall | TR / TF | - | - | 160 | ps |
| TX-Fault Fault | Vf | 2 | - | Vcc | V |
| TX-Fault Normal | Vn | Vee | - | Vee+0.5 | V |
| TX_DISABLE(asserted) | VDH | 2 | - | Vcc | V |
| TX_DISABLE (negated) | VDL | Vee | - | Vee+0.8 | V |
APD Receiver Specifications – Optical
| Parameter | Symbol | Min | Typical | Max | Unit |
| Receiver Sensitivity(OC24) | Rsens-1 | - | -32 | -28 | dBm |
| Receiver Sensitivity(OSNR = 20dB) | Rsens-2 | - | - | -32 | dBm |
| Maximum Input Power | RX-overload | - | - | -7 | dBm |
| Input Operating Wavelength | λ | 1528 | - | 1564 | nm |
| Reflectance | Rrx | - | - | -27 | dB |
| Loss of Signal Asserted | -40 | - | - | dBm | |
| LOS De-Asserted | - | - | -33 | dBm | |
| LOS Hysteresis | 0.5 | - | - | dB |
APD Receiver Specifications – Electrical
| Parameter | Symbol | Min | Typical | Max | Unit |
| Supply Voltage | VccRX | 3.13 | 3.3 | 3.47 | V |
| Differential Output Swing | Vout P-P | 370 | - | 2000 | mV |
| Rise/Fall Time | Tr / Tf | - | - | 175 | ps |
| Loss of Signal –Asserted | VOH | 2 | - | Vcc | V |
| Loss of Signal –Negated | VOL | Vee | - | Vee+0.5 | V |
Low Speed Electrical Signal Timings
| Parameter | Symbol | Min | Typical | Max | Unit |
| TX Disable Negate Time | t-on | - | - | 20 | ms |
| TX Disable Assert Time | t-off | - | - | 20 | ms |
| Time to initialize, including reset of TX_FAULT | t_init | - | - | 300 | ms |
| Start-up Time | t_startup | - | - | 90 | s |
| TX_FAULT/INT Assert Time | t_fault | - | - | 50 | ms |
| TX_DISABLE to Reset | t_reset | 10 | - | - | ms |
| LOS Assert Time | t_los_on | - | - | 100 | us |
| LOS Negate Time | t_los_off | - | - | 100 | us |
| Serial ID Clock Rate | f_serial_clock | - | - | 100 | kHz |