Non Corrosive FM200 Fire Suppression System Without Pollution For Data Center

Price Negotiable
Price: negotiation
MOQ: 1 set
Delivery Time: 10-15 working days
Brand: Air Giant
Product Description

Non Corrosive Fm200 Fire Suppression System Without Pollution For Data Center


• Automatic HFC-227ea/FM200 fire extinguishing system is a set of fire extinguishing, automatic control and fire detection in one system which is the modern intelligent automatic fire extinguishing device.


• HFC-227ea/FM200 is a kind of colourless, odorless, tasteless,noncorrosive, electrical insulated, non-conductive fire agent.


• The ozone-depleting potential value is zero.


• It is currently an ideal substitute for the halon extinguishing agent.


• Assemble agent according to different filling pressure, different capacity, different extinguishing agent and different starting mode.


Device model Filling amount (kg) Maximum working pressure(Mpa) Storage pressure (Mpa) Maximum coverage
(m³)
Starting mode
XQQC16/1.6 16 2.5 1.6 22.22

Starting power:
DC24V/1.6A


Solenoid actuator

XQQC20/1.6 20 2.5 1.6 27.78
XQQC30/1.6 30 2.5 1.6 41.67




Components


The pipe network model of fm200 fire suppression system consists of actually three parts: the pipe network part, the fire fighting equipment part and the electrical elements part. Here will explain the last two parts for customers.


The electrical elements is a set of detecting device, and it always plays a subsidiary role in each system. The electrical elements includes:several control panels, several manual buttons, some discharge indicator lights, some alarm bells, some sounder with light, some smoke detectors and heat detectors.

The main part of the system is fire fighting equipment. It is formed by several components: fm200 cylinders, a cylinder frame, nitrogen-pressure driving devices, a driving device frame, container valves, flexible hoses, liquid flow check valves, gas control pipes, gas flow check valves, manifolds, safety valves, selective valves, flanges, elbows and nozzles.



Working principle


Here is the illustration of working principle to whole system




Application


The pipe network type fm200 fire suppression system is suitable for a lot of places and several kinds of fires. The followings are some examples for customer as reference:


- Telecommunications and data processing

- Switch gear rooms

- Defense applications and cell sites

- High-tech medical application

- Computer rooms

- Telecommunication centers

- Records and data archives

- Testing/imaging equipment

- Reference material

- Chemical laboratories



Advantages


There are a lot of advantages of the single zone fm200 fire suppression system compared to other fire suppression system.


1/ It is the single zone fm200 fire suppression system that can protect the largest volume among the fm200 fire suppression system. Only a single zone system can protect at most 3600 cubic meters.


2/ Using single zone fm200 fire suppression system can help saving money. Obviously, using several systems are more expensive than only using one.


3/ It helps saving place. Because it needs a separate room outside but next to the protected zone, so it won’t waste the places in the protected zone.


4/ The single cylinder has large capacity. It has 120l, 150l, and 180l capacity.


Packages


We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangdong Air Giant Fire Equipment Co.,Ltd.
Location Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
Contact Person Missaya Lu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.