CAL Ig 100 Inert Gas Fire Suppression System 20kg Without Residue
high-quality Inert Gas Nitrogen IG100 Fire Extinguishing System without residue
IG100 uses 100% pressurized nitrogen, which accounts for 78% of the atmosphere, as the extinguishing agent. Its ozone depletion potential (ODP) and global warming potential (GWP) are zero. The atmospheric retention time is zero without any adverse effects on the environment. It fully integrates the design concept of the fire-extinguishing system in the new era, so that the product successfully has the function of environmental protection and efficient fire-fighting.
IG100 characteristics: protecting the ecological environment of the earth, safety and hygiene do not interfere with vision, no stain caused by extinguishing agent, durable of fire fighting effect. Nitrogen can be separated from the air and produced from a wide range of sources at a cheap charge.
Parameters
| No. | Specification | Technical Parameter | |
| 1 | Working Pressure | 20MPa | 30MPa |
| 2 | Device Model | QMD20/80 | QMD30/80 |
| 3 | Capacity | 80Ltr | 80Ltr |
| 4 | Filling Capacity of Gas | 20kg | 24.68kg |
| 5 | Outside Diameter of Cylinder | Φ267mm | Φ267mm |
| 6 | Height of Cylinder | 1910mm | 1770mm |
| 7 | Spraying Time | ≤120s | ≤120s |
| 8 | Max Filling Rate | 0.25kg/L | 0.309kg/L |
| 9 | Power | DC24V/1.6A | DC24V/1.6A |
| 10 | Nitrogen Pressure of Driving Device | 6.0±1.0MPa(20℃) | 6.0±1.0MPa(20℃) |
| 11 | Condition of Reserving Room for Container | temperature: 0~50℃ | temperature: 0~50℃ |
| 12 | Max Working Pressure | 23.2MPa | 36.6MPa |
| 13 | Min Working Pressure | 18MPa | 27MPa |
Components
Storage cylinder group, storage cylinder group frame, nitrogen driving device, nitrogen driving device frame, the cylinder valve, liquid flow check valve, air flow check valve, electromagnetic starter, gas conveying pipeline, collecting pipe, choice valve, three links, reducer tee, reduceing elbow, flange, safety valve, pressure transmitter, pipe, nozzle, chemicals, fire detector, fire controller, sound and light alarm, alarm bell, gas light, emergency start / stop button, etc.
Application
As its name says, the single zone pipe network fm200 fire suppression system is suitable for a single protected zone, whose volume should be less than 3600 cubic meters as well as proportion should be less than 800 square meters. Because of its property and principles of putting off fire, the single zone pipe network fm200 fire suppression system can be used to protect some large and also significant places, such as the followings:
- Computer rooms
- Telecommunication center
- Facilities underground
- Offshore oil extraction
- Library
- Data and paper archives
- Valuable article storage
- Power generator storage room
Advantages
- Compared with the traditional 15MPa system, the number of fire extinguishing agent cylinders can be saved by 25%-50%.
- The building area between cylinders is effectively reduced, and the overall occupation and utilization rate of the building are improved.
- Constant 6MPa low pressure release can reduce the cost of pipeline and pipe fittings.
- The constant release pressure of 6MPa provides more lasting and effective pressure, and the transmission distance can reach 200 meters.
- The release of the whole system with low pressure can only have a less iMPact on personnel on sites, equipment and building structure and it is more safety.
- The external constant pressure reliever can only bear the pressure when the system is spraying, which is convenient for dis-assembly and maintenance and effectively reduces the failure rate of the system.
Packages
We always pack it with polyfoam first and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.