FM200 Enclosed Flooding Fire Extinguishing System For Library UL Certification
FM200 Enclosed Flooding Fire Extinguishing System Without Pollution For Library UL Certification
Description of UL FM200 Fire Suppression System
HFC-227ea gas fire extinguishing device usually includes components such as fire extinguishing agent cylinder group (fire extinguishing agent steel cylinder, cylinder head valve), starter (gas starter, electromagnetic starter, manual starter), release hose, one-way valve, low discharge high seal valve, manifold, manifold safety valve, selection valve, drive cylinder group, release pressure switch, nozzle, fire extinguishing agent delivery pipeline, etc. HFC-227ea gas fire extinguishing devices can be divided into single zone systems and multi zone systems based on the number of protected areas, namely unit independent systems and combined distribution systems.
For a single zone system, after receiving a command from the gas fire extinguishing control panel, the electromagnetic starter opens the bottle head valve (i.e. the active bottle), and the active bottle starts to spray. The gas from the active bottle passes through the starting hose, and opens the bottle head valves (i.e. the driven bottle) of other connected fire extinguishing agent bottle groups, and all gas cylinders start to spray. The extinguishing agent is transported along the pipeline to the protected area and sprayed through nozzles.
Attributes of ULGB series cylinders
|
Material |
HP345 C: ≤0.20% Mn: ≤1.50% Si: ≤0.35% P: ≤0.025% S: ≤0.015% Al((Acid solubility)): ≥0.015 |
| Working pressure | 53 bar |
| Air tightness test pressure | 80 bar |
| Burst pressure | 0 °C ~ 50 °C |
| Operating temperature range | Red polyester powder spraying |
| Surface Paint | GB |
Features of UL FM200 Fire Suppression System
- Very stable behaviour.
- Rapid extinguishing time with discharge in less than 10 seconds.
- High efficiency, low extinguishing concentration
- Applicable in occupied areas
- Low storage pressure with low noise discharges.
- Minimum container footprint.
- Leaves no residue after discharge.
- Electrically non-conductive, Safe for use in Human occupied areas.
- Zero ozone depleting potential
Application of UL FM200 Fire Suppression System
- Bank vault
- Laboratory
- Rare Book Library
- Electronic data room
- Telecom switching room
- Studio
- Communication Center
- Transformer room and distribution room
- Electrical control room
- Auxiliary power room
- Combustible liquid storage room
- Computer room
Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.