UL HFC227ea fire suppression system without pollution for data center
UL HFC227ea fire suppression system without pollution for data center
Description of UL FM200 Fire Suppression System
One of the most environmentally friendly systems is the HFC227EA Clean Agent Suppression System. By physically cooling the fire by eliminating the heat energy that interrupts the combustion cycle, it prevents the fire from being able to sustain itself. With the 227 system, UL certified
HFC227ea disinfectant gas provides safe fire protection for people, property and life stock. The most challenging aspect of the use of environmentally friendly suppression agents is that they can affect the ozone layer, but the HFC227EA system is completely echo friendly and is not a depleting ozone suppression agent, although sometimes the fumes produced by fighting fires can affect the ozone layer.
Attributes of UL DOT series cylinders
| Model No. | Nominal pressure (bar) | Nominal volume(L) | Filling volume (kg) |
Caliber (mm) |
Weight (kg) |
|
| Min. | Max. | |||||
| AG227SP-25-49S | 25 | 49 | 23.5 | 54.9 | 49 | 48 |
| AG227SP-25-52S | 25 | 52 | 25.0 | 58.2 | 49 | 56 |
| AG227SP-25-62S | 25 | 62 | 29.8 | 69.4 | 49 | 53 |
| AG227SP-25-80S | 25 | 80 | 38.4 | 89.6 | 49 | 65 |
| AG227SP-25-103S | 25 | 103 | 49.4 | 115.4 | 49 | 82 |
| AG227SP-25-106S | 25 | 106 | 50.9 | 118.7 | 49 | 84 |
| AG227SP-25-147S | 25 | 147 | 70.6 | 164.6 | 49 | 105 |
| AG227SP-25-153S | 25 | 153 | 73.4 | 171.4 | 49 | 108 |
| AG227SP-25-16.7R | 25 | 16.7 | 8.0 | 18.7 | 33 | 21 |
| AG227SP-25-28.3R | 25 | 28.3 | 13.6 | 31.7 | 33 | 29 |
| AG227SP-25-49R | 25 | 49 | 23.5 | 54.9 | 33 | 42 |
| AG227SP-25-52R | 25 | 52 | 25.0 | 58.2 | 33 | 50 |
| AG227SP-25-62R | 25 | 62 | 29.8 | 69.4 | 33 | 47 |
Features of UL FM200 Fire Suppression System
- No residual after discharge
- Electrical non conductive
- 25Bar operating pressure
- Suitable for flammable liquids and solids combustible materials
- Optional: operating pressure of 42bar
- Design concentration 7%
- Suitable for occupied rooms
- The full discharge period is 10 seconds
Application of UL FM200 Fire Suppression System
- Bank vault
- Laboratory
- Rare Book Library
- Electronic data room
- Telecom switching room
- Studio
- Communication Center
- Transformer room and distribution room
- Electrical control room
- Auxiliary power room
- Combustible liquid storage room
- Computer room
Packages of UL FM200 Fire Suppression System
We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.