150-300 Bar Inert Gas Fire Suppression System Cylinder Manufacturer
150-300 Bar Inert Gas Fire Suppression System Cylinder Manufacturer
Inert gas fire extinguishing systems are the safe, natural way to extinguish a fire. Because of its unique patented valve assembly, the agent enters the protected zone within the industry required 60 seconds but at a steady flow rate — preventing destructive turbulence from occurring. This constant flow rate allows for the use of small-diameter, low pressure (and less expensive) piping from the inert gas container all the way to the nozzle. And, the necessary venting area is much smaller, which can reduce installation costs by as much as 60% on venting hardware.
Parameters
| No. | Specification |
IG100(100% nitrogen) IG55(50% nitrogen;50% argon) IG541(52% nitrogen;40% argon,8%carbon dioxide) |
|||
| 1 | Capacity | 80Ltr | 140ltr | ||
| 2 | Working Pressure | 20MPa | 30MPa | 20MPa | 30MPa |
| 3 | Device Model | QMH20/80 | QMH30/80 | QMH20/140 | QMH30/140 |
| 4 | Filling Capacity of Gas | 22.32kg | 33.48kg | 42kg | 58.2kg |
| 5 | Outside Diameter of Cylinder | Φ279mm | Φ267mm | Φ406mm | Φ356mm |
| 6 | Height of Cylinder | 1710mm | 1870mm | 1460mm | 1925mm |
| 7 | Filling Rate | 0.299kg/L | 0.415kg/L | 0.300kg/L | 0.201kg/L |
| 8 | Spraying Time | ≤120s | |||
| 9 | Power | DC24V/1.6A | |||
| 10 | Nitrogen Pressure of Driving Device | 6.0±1.0MPa(20℃) | |||
| 11 | Condition of Reserving Room for Container | temperature: 0~50℃ | |||
Features and benefits
- Suitable for occupied areas
- Electrically non – conductive
- Chemically inert
- Colourless, odourless and flavourless
- No residue to clean up after the discharge
- Zero Ozone Depletion Potential (ODP)
- No greenhouse effect
- No global warming impact
- No decomposition products
- No fog and no loss of post-discharge visibility
- Non corrosive/toxic
- Stored as a gas
- Suitable for occupied areas
- Excellent post-discharge visibility
- Very low refill cost.
- Easy to obtain anywhere in the world
Application
- Telecommunications and data processing
- Switch gear rooms
- Defense applications and cell sites
- High-tech medical application
- Computer rooms
- Telecommunication centers
- Records and data archives
- Testing/imaging equipment
- Reference material
- Chemical laboratories