Guangdong Air Giant Fire Equipment Co.,Ltd.
                                                                                                           
Verified Supplier
4 Years
Since 2022
Menu

NOVEC1230 Fire Suppression System

Price Negotiable
Price: negotiation
MOQ: 1 set
Delivery Time: 10-15 working days
Brand: Air Giant
Product Description

NOVEC1230 Fire Suppression System With No Contamination Of Storage Rooms Using Noncorrosive With UL Certification

 

Description of UL NOVEC1230 container

 

-- Attributes of Welded Steel GB series container

 

 

 

Material

HP345

Carbon:         

0.20%

Manganese:  

1.50%

Silicon:             

0.35%

Phosphorus: 

0.025%

Sulphur:        

0.015%

Aluminium acid-soluble: 

0.015

Nominal Working Pressure

53 bar

Hydrostatic Test Pressure

80 bar

Work Temperature

0 °C ~ 50 °C

Paint Specification

Red Polyester Powder Coated

Certification

GB

 

-- FK-5-1-12 (NOVEC1230) Welded Container Assembly Details : GB Container

Cylinder with

Valve Assembly

Part No.

Container

Assembly

Type

Nominal

Working

Pressure

(bar)

Nominal

Cylinder

Volume

 

(L)

Fill Capacity

(kg)

Outlet

Size

(mm)

Empty

Weight

(kg)

Min.

Max.

813.101.0455

AG5112SPA-40

25

40

19.2

44.4

33

41

813.101.0465

AG5112SPA-50

50

24.0

55.5

33

52

813.101.0475

AG5112SPA-60

60

28.8

66.6

33

59

813.101.0486

AG5112SPA-70

70

60

77.7

49

72

813.101.0496

AG5112SPA-80

80

60

88.8

49

80

813.101.0506

AG5112SPA-90

90

60

99.9

49

94

813.101.0516

AG5112SPA-100

100

60

111

49

100

813.101.0526

AG5112SPA-120

120

60

133.2

49

113

813.101.0536

AG5112SPA-140

140

67.2

155.4

49

107

813.101.0546

AG5112SPA-150

150

72.0

166.5

49

134

813.101.0566

AG5112SPA-170

170

81.6

188.7

49

124

813.101.0576

AG5112SPA-180

180

86.4

199.8

49

130

813.101.0455

AG5112SPA-40

42

40

19.2

44.4

33

41

813.101.0465

AG5112SPA-50

50

24.0

55.5

33

52

813.101.0475

AG5112SPA-60

60

28.8

66.6

33

59

813.101.0485

AG5112SPA-70

70

60

77.7

49

72

813.101.0495

AG5112SPA-80

80

60

88.8

49

80

813.101.0505

AG5112SPA-90

90

60

99.9

49

94

813.101.0518

AG5112SPA-100

100

60

111

49

100

813.101.0528

AG5112SPA-120

120

60

133.2

49

113

813.101.0538

AG5112SPA-140

140

67.2

155.4

49

107

813.101.0548

AG5112SPA-150

150

72.0

166.5

49

134

813.101.0568

AG5112SPA-170

170

81.6

188.7

49

149

813.101.0578

AG5112SPA-180

180

86.4

199.8

49

130

 

 

Description of UL NOVEC1230 Fire Suppression System

 

FK-5-1-12, like halon, extinguishes by causing a chemical reaction with the combustion products, and does not remove oxygen like CO2  and other inert agents.

Therefore, exposure to FK-5-1-12 at the design concentration of 4.5% (Class A and Class C Minimum Design Concentration) and 5.85% (Class B Minimum Design Concentration) is not hazardous to health. FK-5-1-12 systems for spaces that are normally occupied and designed to concentrations up to the NOAEL (10%) shall be permitted,  but  maximum   exposure  shall  not  exceed  than   5  min.  Exposure  to  higher   concentrations  is permissible  for limited periods. Refer to NFPA 2001  Section  "Safety"  for  exposure requirements. As with halons,  the  US  EPA  and  the  National  Fire  Protection  Association  (NFPA)  recommend  that  unnecessary exposure to any agent be avoided and that personnel evacuate protected areas as quickly as possible to avoid the decomposition products of the fire.

 

Components of UL NOVEC1230 Fire Suppression System

No.

Part Name

No.

Part Name

1

Cylinder

7

Pilot Hose

2

Mounting Bracket

8

Pneumatic Actuator

3

Fix Steel Channel

9

Bleed Valve

4

Container Valve

10

Discharge Pressure Switch

5

Electrical Actuator

11

Nozzle

6

Valve Outlet Adaptor

 

 

 

 

Features of UL NOVEC1230 Fire Suppression System

 

FK-5-1-12 is a clean agent containing no particles or oily residues. It is produced under ISO 9001 guidelines to strict manufacturing specifications ensuring product purity. FK-5-1-12 leaves no residue or oily deposits on delicate electronic equipment, and can be removed from the protected space by ventilation.

FK-5-1-12 is a liquid at room temperature with a low vapor pressure, which allows for ease in handling, storage, and shipping. FK-5-1-12 is thermally and chemically stable, zero ozone  depletion potential, atmospheric lifetime of five days only. It has unique qualities that provide   the right balance of fire extinguishing performance,end use safety,and environmental sustainability.

 

Application of UL NOVEC1230 Fire Suppression System

 

üComputer room, communication room, power distribution room, library, archives, Museum, etc.

 

ü Be used for electrical fire, liquid fire, solid fire, gas fire which can be cut off the gas source before extinguishing occur, etc.

 

 

Packages of UL NOVEC1230 Fire Suppression System

 

We always pack it with polyfoam firstly and then put it into a wooden case. Sometimes, in order to meet with customers or the safety requirement, we will make a pallet for the goods.

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Guangdong Air Giant Fire Equipment Co.,Ltd.
Location Factory 101, Building 2, No. 2, Shaxing Road, Lanhe Town, Nansha District, Guangzhou,China
Contact Person Missaya Lu

Request A Quote

Please check your email address.
Your message must be at least 20 characters.