Rohde & Schwarz FSQ26 Signal Analyzer with 20Hz-26.5GHz Frequency and High-End Dynamic Range
Price:
Negotiation
MOQ:
1 set
Delivery Time:
Negotiable
Brand:
Rohde and Schwarz
Product Description
20Hz-26.5GHz RS Spectrum Analyzer, Rohde & Schwarz FSQ26 Signal Analyzer
Product Overview
The Rohde & Schwarz FSQ26 signal analyzer combines two instruments in one, offering signal analysis at a demodulation bandwidth of up to 120 MHz with the dynamic range of a high-end spectrum analyzer.
Key Features
- Frequency range: 20 Hz to 3.6 GHz, 8GHz, 26.5GHz and 40 GHz
- Dynamic range of a high-end spectrum analyzer
- TOI + 25 dBm, typ.
- 1 dB compression +13 dBm, typ.
- 84 dB ACLR/3GPP with noise correction
- 28 MHz demodulation bandwidth (optional 120 MHz)
- 16 Msample I and Q memory
- Application firmware for digital demodulation measurement
Supported Applications
- Bluetooth
- GSM/EDGE
- 3GPP WCDMA, HSDPA, TD-SCDMA
- CDMA2000, 1xEV-DV, 1xEV-DO
- WLAN 802.11a/b/g/j
- WiMax IEEE 802.16-2004, 802.16e
- General purpose vector signal analysis
Available Options
| Option Code | Description |
|---|---|
| B10 | External generator control for FSP, FSU, FSG, FSQ, ESU, ESCI, ESPI and for retrofit |
| B100 | I/Q memory extension 235 Msamples Extendable up to 705 Msamples (Not retrofittable, excludes FSP-B10) |
| B102 | I/Q memory extension Extends FSQ-B100 to 705 Msamples (FSQ-B100 required) |
| B12 | Output attenuator for tracking generator for FSU, FSQ |
| B16 | LAN Interface |
| B17 | Digital Baseband Interface Not retrofittable |
| B18 | Removable Hard Disk (not retrofittable) |
| B19 | Second Hard Disk for FSQ-B18 (for FSQ-B18, variant 1303.0400.03) |
| B21 | LO/ZF connections for external mixers (for FSQ26, FSQ40,FSU26, FSU43, FSU46, FSU50) |
| B23 | Preamplifier 20 dB to FSQ26, 3.6 GHz - 26.5 GHz (not retrofittable, requires FSU-B25) |
| B24 | Preamplifier 30dB, 100 kHz to 50GHz (for FSMR26/43/50, FSQ26/40, FSU26/43/46/50) |
| B25 | Electronic attenuator 0 to 30 dB, Preamplifier 20 dB, 10MHz - 3.6 GHz for FSU, FSQ |
| B28 | Trigger port for FSP,FSQ,FSU; for indication of trigger conditions |
| B33 | Disabled USB ports excludes FS-K9 |
| B4 | OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR |
| B5 | Output for low phase noise 640MHz reference signal for FSU3, FSU8, FSQ3 und FSQ8 |
| B71 | Analogue base band inputs 50 Ohm/1M Ohm input impedance information bandwidth 36 MHz |
| B72 | Bandwidth extension for IQ-Demodulation and Vectorsignalanalysis 120MHz IQ bandwidth |
| B88 | RF hardware option 1 FSQ26 |
| B9 | Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz |
| C3 | Three years of depot calibration coverage based on the R&S recommended calibration interval |
| C5 | Five years of calibration coverage based on the R&S recommended calibration interval |
| DCV-2 | Documentation of calibration values |
| DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
| DKD | FSQ26 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
| EX-IQ-BOX | Digital I/O adapter module for AFQ, AMU, FMU, FSG, FSQ, SMJ, SMU |
| FS-B33 | USB mass memory write protection, disables writing to USB memory sticks (ex factory only) |
| FS-K10 | GSM/EDGE/EDGE Evolution Measurement Appl (for FSG/FSQ/FSU) |
| FS-K110 | Analysis of TETRA II / TEDS signals (for FSQ, FSU with option FSU-B73) |
| FS-K15 | VOR/ILS measurements for FSMR |
| FS-K40 | Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU |
| FS-K5 | Application firmware GSM/EDGE tests for FSP, FSU, FSQ |
| FS-K5U | Upgrade of FS-K5 to FS-K10, GSM/EDGE/EDGE Evolution Measurement Appl (for FSG, FSQ, FSU) |
| FS-K7 | FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU) |
| FS-K72 | Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ |
| FS-K73 | Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ |
| FS-K73+ | 3GPP HSPA+ UE transmitter test, application firmware (for FSMR, FSP, FSQ, FSU, FSUP) |
| FS-K74 | 3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ |
| FS-K74+ | 3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG) |
| FS-K76 | 3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU |
| FS-K77 | 3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU |
| FS-K8 | Application firmware for Bluetooth measurement on FSP, FSU and FSQ |
| FS-K82 | CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ |
| FS-K83 | CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU |
| FS-K84 | 1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ |
| FS-K85 | 1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU |
| FS-K9 | Measurements with NRP power sensors NRPZ11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4 |
Frequently Asked Questions
Can you ship orders to Canada or Australia?
Yes, we can. We send orders worldwide.
What delivery method do you use and what is the delivery time?
We can ship by EMS, DHL, FedEx, UPS, TNT with tracking number. Usual delivery time is 4-7 workdays.
What is your payment term?
100% T/T payment before shipment.
How can I ask any other question?
You can contact us online or leave us messages below.
Product Images
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Meigaolan Electronic Instrument Co. Ltd
Location
RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Contact Person
Dannie