Keysight Agilent E4440A PSA RF Spectrum Analyzer 3 Hz to 26.5 GHz Rackmount Pre-Owned
Price:
Negotiation
MOQ:
1 set
Delivery Time:
Negotiable
Brand:
Keysight/Agilent
Product Description
E4440A PSA RF Spectrum Analyzer Multipurpose Keysight Agilent
Product Overview
The Keysight Agilent E4440A PSA high-performance spectrum analyzer measures and monitors complex RF and microwave signals up to 26.5 GHz. With optional external mixing, the frequency coverage expands to 110 GHz using Agilent external mixer, and to 325 GHz using other vendors' mixers.
Migration to PXA Series
The PXA N9030A, Agilent's next-generation high-performance signal analyzer, combines the PSA's technical excellence with state-of-the-art technologies, making it a logical form-fit-functional replacement for the PSA. The new PXA N9030A offers greater performance, wider analysis bandwidth, and more powerful connectivity.
Key Performance Specifications
- ±0.19 dB absolute amplitude accuracy
- -155 dBm (-169 dBm with preamp) displayed average noise level (DANL)
- -118 dBc/Hz phase noise at 10 kHz offset
- 81 dB W-CDMA ACLR dynamic range
Analysis Bandwidth Capabilities
- 10 MHz analysis bandwidth (Option B7J for Basic mode)
- Optional 40 or 80 MHz analysis bandwidth to capture and measure complex signals
- -78 dB (nominal) third order intermodulation for 40 or 80 MHz analysis bandwidth
- Up to 300 MHz analysis bandwidth for calibrated VSA measurements
Platform Flexibility
- Flexible platform with 16 optional, easy-to-use built-in measurement personalities and hardware options
- Agilent's PowerSuite one-button power measurements included as standard
Available Options
| Option Code | Description |
|---|---|
| 015 | 6 GHz return-loss Measurement Accessory Kit |
| 033 | Measuring receiver connector accessory kit |
| 071 | Digital Demodulation H/W for S/N USUS4142/MY4140 Changed to B7J on newer models |
| 0B0 | Do not include manuals |
| 0B1 | Add Manual Set |
| 0BV | Service Documentation, Component Level |
| 0BW | Service Documentation, Assembly Level |
| 107 | Audio input 100 kOhm |
| 110 | RF/uW internal preamplifier |
| 111 | USB device side I/O interface (Shipped Standard on S/N >MY4614) |
| 115 | 512 MB user memory (Shipped Standard on S/N >MY4614) |
| 117 | Secure memory erase |
| 119 | Noise Figure Hardware Kit. Standard on all models S/N > US4222/MY4100. |
| 122 | 80 MHz bandwidth digitizer |
| 123 | Switchable MW preselector bypass |
| 124 | Y-axis video output |
| 140 | 40 MHz Bandwidth Digitizer |
| 1A7 | PSA Series ISO 17025 compliant calibration with test data |
| 1CM | Rackmount Kit |
| 1CN | Handle kit |
| 1CP | Rack mount kit with handles |
| 1CR | Rack slide kit |
| 1DS | RF internal preamplifier |
| 202 | GSM w/EDGE Measurement Personality |
| 204 | 1xEV-DO Measurement Personality |
| 210 | HSDPA/HSUPA measurement personality |
| 211 | TD-SCDMA measurement personality |
| 212 | TD-SCDMA Modulation Analysis Measurement Personality |
| 213 | HSPA/8PSK for TD-SCDMA Modulation Analysis Measurement Personality |
| 214 | 1XEV-DV measurement personality |
| 215 | External Source Control Measurement Personality |
| 217 | WLAN Measurement Personality |
| 219 | Noise figure measurement personality |
| 226 | Phase noise measurement personality |
| 230 | Benchlink web remote control software |
| 233 | Built-in measuring receiver personality |
| 235 | Wide BW digitizer external cal wizard |
| 239 | EMC measurement personality |
| 23A | AM/FM/PM triggering for measuring receiver |
| 23B | CCITT filter for audio measurements |
| 241 | Flexible digital modulation analysis |
| 266 | Programming code compatibility suite measurement personality (8566/8568/8590 series/8560 series) |
| 423 | Switchable Microwave Preselector Bypass. Available for all models with S/N |
| 426 | Gated Sweep Hardware. Standard on all models >S/N US/MY4336. |
| 511 | Without digital demodulation hardware |
| 512 | STND (TYPE N CONNECTOR) |
| 516 | 40 MHz BW IF output - low band |
| 517 | Boris DIF --with opt 122 or 124 |
| 518 | Natasha DIF -- no opt 122 or 124 |
| 520 | Preselector bias cable - no opt HNQ |
| 521 | STD WB Analog IF board |
| 524 | SCSI interface card and dress panel |
| 627 | Required for all options except HT1 |
| 628 | Required for all options except 111 |
| 630 | Required for option 110 without 123 |
| 631 | Required for 123 without 110 |
| 632 | Required for option 110 with 123 |
| 633 | Required for all options except HS1, HS7 and HT1 |
Application Software
- 8PSK (/213)
- Flexible Digital (/241)
- GSM with Edge (/202)
- HSDPA (/210 /213)
- HSUPA (/210)
- MATLAB (/N6171A /N6171A-M01 /N6171A-M02 /N6171A-M03)
- Noise Figure (/119)
- Phase Noise (/226)
- TD-SCDMA (/213)
- W-CDMA (/BAF)
- CDMA2000 (/B78)
- CDMAONE (/BAC)
Frequently Asked Questions
Can you ship orders to Canada or Australia?
Yes, we can. We send orders worldwide.
What delivery method do you use and what is the delivery time?
We can ship by EMS, DHL, FedEx, UPS, TNT with tracking number. Usual delivery time is 4-7 workdays.
What is your payment term?
100% T/T payment before shipment.
How can I ask any other question?
You can contact us online or leave us messages below.
Product Images
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Meigaolan Electronic Instrument Co. Ltd
Location
RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Contact Person
Dannie