Fluke 8846A 6.5 Digit Precision Multimeter with 0.0024% DC Accuracy and 10A Current Range
The Fluke 8846A 6.5 digit precision multimeter delivers exceptional precision and versatility for demanding measurements, whether on the bench or in system applications. This high-performance, feature-rich digital multimeter combines ease of use with comprehensive measurement capabilities.
This multifunction DMM measures volts, ohms, and amps with basic V dc accuracy up to 0.0024%, a 10 A current range, and wide ohms range. Additional capabilities include frequency and period measurement, temperature sensing, and capacitance measurement. Built-in counter, capacitance meter, and thermometer functions provide unparalleled versatility.
Advanced display modes include Trendplot™ paperless recorder, statistics, and histograms—features not commonly found on other multimeters. Built with Fluke's renowned durability and dependability, the 8846A offers exceptional value for manufacturing test, research and development, and service applications.
- 6.5 digit resolution
- Wide ohms range from 10 Ω to 1 GΩ with up to 10 μΩ resolution
- Dual display capability
- USB memory drive port
- Basic V dc accuracy of up to 0.0024%
- 100 μA to 10 A current range, with up to 100 pA resolution
- Graphical display functionality
- 2 x 4 ohms 4-wire measurement technique
- CAT I 1000 V, CAT II 600 V safety ratings
- Trendplot™ paperless recorder mode, statistics, histogram
- Fluke 45 and Agilent 34401A emulation
- Measure frequency and period, capacitance and temperature
- LCI Line Cord
- TL71 Test Lead Set, Premium DMM
- WEEE Information Sheet
- USB to RS232 Cable Adapter
- Statement of Calibration Practices
- FlukeView Forms - Basic for 8845/8846
- Warranty Information
| Model Number | Description |
|---|---|
| 884X-1G | USB Memory 1 GB |
| 884X-512M | USB Memory 512 MB |
| FVF-UG | FlukeView Software Upgrade no Cable |
| SU | FlukeView Forms Software upgrade w/cable |
| TL-71 | Test Lead Set |
| TL910 | Electronic Test Probes |
Input connectors for Volts, 2-wire Ohms, Hz, Period, Temperature, and Capacitance measurements. Input connectors source current for 4-wire Ohms measurements. All measurements use the Input LO connector as a common input. The LO input is isolated, and may be safely floated up to 1000 V above earth ground regardless of the measurement type. 1000 V is the maximum voltage rating between the Input HI and LO connectors and between each HI and LO input and earth ground.
Sense connectors sense the voltage across the unknown resistance for 4-wire Ohms measurements or provide the DCV reference Input for DCV Ratio measurements.
Soft keys are used to select various menu options while navigating the Meter's menus. Each soft key's function is identified with a label in the bottom row of the display. Keys without a label above them are inactive.
Accesses internal and external memory containing meter setups and measurements.
Connection for optional memory device to store meter readings.
Turns off the display. While in standby, the Meter will not respond to remote or front-panel commands. When taken out of standby, the Meter sets itself to its power-up configuration.
Accesses communication interface selection and setup, remote command set, system settings, and meter reset.
Accesses resolution setting, trigger functions, temperature setup, dBm reference selection, continuity settings, and other measurement related parameters.
Triggers measurement when trigger is set to external triggering.
Accesses math functions, Statistics, TrendPlot, and Histogram.
Uses the present reading as an offset value to create relative readings.
Selects meter function between volts dc, volts ac, amp dc, amps ac, ohms, continuity, diode test, frequency, period, capacitance, and temperature.
Selects between manual and auto range mode. Also increases or decreases the range when in manual ranging mode.
Backs up one layer in the menu selection.
All front-panel input connectors, except 10 A, are available on the rear-panel of the Meter. These switches switch the Meter's input between them.
Input connectors for ac and dc current measurement functions.
- A. Line Power Cord connector
- B. Power Switch
- C. Fuse holder and power line voltage selector
- D. Rear-panel input connectors
- E. External trigger input and measurement complete output port
- F. Ethernet (LAN) connector
- G. RS-232 connector
- H. IEEE 488 (GPIB) connector
- I. Ground connector
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.