Ando AQ6331 Portable Optical Spectrum Analyzer for 50 GHz DWDM Network Testing with Long Wavelength Capability
The AQ6331 is a new portable optical spectrum analyzer (OSA) offering the advanced performance required for 50 GHz DWDM network testing in both C-band and L-band. The AQ6331 delivers excellent wavelength resolution, accuracy, and dynamic range comparable to conventional bench-top OSAs for research and development applications. Thanks to its unique rugged design and portability, the AQ6331 is an ideal tool for field applications such as construction, inspection, and maintenance work. It can also be used in production and quality control processes (e.g., component test and measurement). The AQ6331 is the only portable optical spectrum analyzer to bring scientific specifications into field applications.
- Compact and lightweight: Approximately 10 kg
- Wavelength accuracy: ±0.02 nm (1520-1580 nm) ±0.05 nm (1580-1620 nm)
- Wavelength resolution: 0.05 nm (minimum)
- Dynamic range: 55 dB (peak ±0.4 nm) 40 dB (peak ±0.2 nm)
- Internal wavelength calibration with built-in wavelength reference
- One-key operation with built-in user programming function
- Unique long-term measurement function to monitor DWDM system stability and performance
- Various built-in analysis functions
| Applicable fiber | Single mode fiber (10/125 µm) |
|---|---|
| Applicable Connector | FC-PC (Standard) |
| Wavelength range | 1200 to 1700 nm |
| Wavelength accuracy | ±0.02 nm (1520 to 1580 nm), < ±0.05 nm (1580 to 1620 nm), ±0.3 nm (1200 to 1700 nm) |
| Wavelength linearity | ±0.01 nm (1520 to 1580 nm), < ±0.02 nm (1580 to 1620 nm) |
| Wavelength reproducibility | ±0.005 nm (1 min.) |
| Wavelength resolution | 0.05 nm (Resolution setting: 0.05 nm, 1520 to 1620 nm) 0.1 nm (Resolution setting: 0.1 nm, 1520 to 1620 nm) Resolution setting: 0.05, 0.1, 0.2, 0.5, 1.0 nm Resolution accuracy: < ±5% (Resolution setting: ≤ 0.2 nm) |
| Measurement level range | -90 to +20 dBm (1200 to 1600 nm, sensitivity: HIGH3) -80 to +20 dBm (1600 to 1700 nm, sensitivity: HIGH3) |
| Level accuracy | ±0.3 dB typ. (1550 nm, 1600 nm) |
| Polarization dependency | ±0.05 dB (1550 nm, 1600 nm) |
| Level linearity | ±0.05 dB (Input power: 0 to -50 dBm, sensitivity: HIGH 1 to 3) |
| Level flatness | ±0.1 dB (1520 to 1580 nm) ±0.2 dB (1520 to 1620 nm) |
| Level reproducibility | ±0.02 dB (1550 nm, 1600 nm) |
| Dynamic range | 55 dB (1523 nm, peak ±0.4 nm, 0.05 nm resolution) 40 dB (1523 nm, peak ±0.2 nm, 0.05 nm resolution) |
| Return loss | 30 dB typ. (Optical input, 1550 nm, 1600 nm) |
| Sweep time | Approx. 0.5 sec. (Span: 50 nm, sensitivity: NORMAL HOLD, number of sampling: AUTO, average: 1) |
| Functions | Measurement condition, Trace display, Data analysis, Others |
| Memories | FDD (3.5-inch 2HD), Internal memory (2MB) |
| Data output | Built-in high-speed printer |
| Interfaces | GP-IB, RS-232C, Keyboard (IBM compatible), Mouse (PS/2), Video (SVGA), Printer (Centronics), PCMCIA (1 x Type 3 or 2 x Type 2) |
| Display | 8.4-inch color LCD (800 x 600 dots) |
| Power requirements | AC100 to 120 V, AC200 to 240 V, 48 to 63 Hz, approx. 100 VA |
| Environmental conditions | Operating temperature: 0 to 50°C Storage temperature: -20 to 60°C Humidity: 90% or less (no condensation) |
| Dimensions and mass | Approx. 315(W) x 200(H) x 255(D) mm, approx. 10 kg |
| RMS | REMOTE MODEM SW |
|---|---|
| TC | TRANSIT CASE |
Get in Touch