Rohde and Schwarz ZVA50 50GHz Four-Port Vector Network Analyzer for Pulsed Measurements
Price:
Negotiation
MOQ:
1 set
Delivery Time:
1~3 Working Days
Brand:
Rohde and Schwarz
Product Description
Rohde and Schwarz ZVA50 Network Analyzer Multipurpose Benchtop Used Test Equipment
Product Overview
The Rohde & Schwarz ZVA50 is the world's first four-port 50 GHz network analyzer. Featuring two integrated sources, this analyzer enables measurements on multiport and balanced components in this frequency range using a single instrument. The ZVA50 also offers exceptional features and specifications for pulsed measurements in radar and satellite applications.
Key Features
- Second integrated source eliminates need for external generator in intermodulation and mixer measurements
- 10x faster frequency sweeping compared to external solutions
- Simultaneous S-parameter and intermodulation measurements
- Four-port architecture for testing balanced components
- Integrated coherent sources for measuring linear and nonlinear DUTs
- User-configurable phase offset between signals
- Comprehensive wizards for complex measurement tasks
- Up to 60,000 measurement points per trace
- 100 trace display capacity
- 15 MHz measurement bandwidth with 12.5 ns time resolution
- 130 dB dynamic range and +13 dBm output power
Technical Specifications
- High-end network analyzer of the ZVA series
- Pulsed profile measurement option
- True differential measurements option
- High measurement speed
- Versatile functionality
- GPIB, LAN, USB interfaces
- Multiport concept
- Two internal sources
- Highest network analyzer performance
- Modern user interface (Windows)
Available Options
| Option Code | Description |
|---|---|
| B-B18 | Removable Flash Disk 4GB for ZVA/ZVB with control unit FMR6/5 (factory installed only) |
| B-B18 | Removable Flash Disk 4GB for ZVA/ZVB with controller unit FMR7/3 or FMR7/6 |
| B-B18 | Removable hard disk 160GB (including firmware) for R&S® ZVA and R&S® ZVB with FMR7 |
| B-B4 | Oven quartz (OCXO) for ZVA, ZVB, ZVT |
| B-K2 | Time domain (for ZVA, ZVB, ZVT) (software license) |
| B-K30 | Noise figure measurement on 2 port devices (for ZVA and ZVT) |
| B16 | Direct generator and receiver access for 2 port ZVA50 |
| B16 | Direct generator and receiver access for 4 port ZVA50 |
| B21 | Generator Step Attenuator Port 1, mechanical, 50dB in 10dB-steps |
| B22 | Generator Step Attenuator Port 2, mechanical, 50dB in 10dB-steps |
| B23 | Generator Step Attenuator Port 3, mechanical, 50dB in 10dB-steps |
| B24 | Generator Step Attenuator Port 4, mechanical, 50dB in 10dB-steps |
| B31 | Receiver Step Attenuator Port 1, mechanical, 35dB in 5dB-steps |
| B32 | Receiver Step Attenuator Port 2, mechanical, 35dB in 5dB-steps |
| B33 | Receiver Step Attenuator Port 3, mechanical, 35dB in 5dB-steps |
| B34 | Receiver Step Attenuator Port 4, mechanical, 35dB in 5dB-steps |
| B7 | Measurements on pulsed signals. Pulse Profile, Recording time up to 25ms, up to 30MHz bandwidth |
| B7 | Measurements on pulsed signals. Pulse profile, Recording time up to 25ms, up to 30MHz bandwidth |
| B8 | External attenuator control. Control unit for electronic attenuators of ZVAZ90E, ZVA-Z110E |
| C3 | Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data |
| C3 | Three years of depot calibration coverage based on the R&S recommended calibration interval - includes test data |
| C5 | Five years of calibration coverage based on the R&S recommended calibration interval - includes test data |
| C5 | Five years of calibration coverage based on the R&S recommended calibration interval - includes test data |
| DCV-2 | Documentation of calibration values |
| DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
| K10 | Group delay measurement on converters without LO access. For long distances via LXI network of 2 ZVA or ZVT |
| K17 | Increases the receiver bandwidth to 5MHz (software license) |
| K27 | Two internal pulse generators (for ZVA and ZVT) (software license) |
| K4 | Mixer- and frequency converting measurements for ZVA and ZVT (software license) |
| K5 | Vector corrected mixer measurements (for R&S®ZVA, R&S®ZVT; R&S®ZVA/T-B16 and R&S®ZVA-K4 required) |
| K6 | True Differential Measurements for all 4-port ZVA and for ZVT with at least 3 ports |
| K7 | Measurements on pulsed signals pulse profile, recording time up to 3ms up to 30 MHz bandwidth |
| K8 | Control of frequency converters (for ZVA with f>20 GHz, ZVT20, includes ZVA-K4) |
| K9 | Measurement of group delay on frequency converters without LO access (for ZVA, ZVT) |
| R3 | Three years of depot repair coverage, including re-calibration if necessary to complete the repair |
| R3 | Three years of depot repair coverage, including re-calibration if necessary to complete the repair |
| R5 | Five years of depot repair coverage, including re-calibration if necessary to complete the repair |
| R5 | Five years of depot repair coverage, including re-calibration if necessary to complete the repair |
Our Service
- One-stop service from manufacture to shipping
- Inquiries related to our products or prices replied within 24 hours
- Well-trained and experienced staff fluent in English
- Distributor support for unique designs and current models
- Protection of your sales area, design ideas, and private information
Frequently Asked Questions
Can you ship orders to Canada or Australia?
Yes, we can. We send orders worldwide.
What delivery methods do you use and what is the delivery time?
We ship by EMS, DHL, FedEx, UPS, TNT with tracking numbers. Usual delivery time is 4-7 workdays.
What is your payment term?
100% T/T payment before shipment.
How can I ask any other questions?
You can contact us online or leave us messages below.
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Meigaolan Electronic Instrument Co. Ltd
Location
RA1-B2,F32 of Dongjianghaoyuan, Baomin Rd, Bao'an District, Shenzhen,China
Contact Person
Dannie