Pre-Owned Rohde and Schwarz FSU67 Spectrum Analyzer with 20Hz to 67GHz Range and Low Noise Floor
The R&S FSU67 is the first spectrum analyzer with a direct frequency range to 67 GHz and fundamental mixing. It allows measurements to 67 GHz without using cumbersome setups with external mixers.
- Simplified test set-ups with just one connection from 20 Hz to 67 GHz
- Full span sweep of 67 GHz
- Unambiguous frequency indication without the image response and multiple responses known from external harmonic mixers
- Wider level range with a much higher allowable reference level than with harmonic mixers
- Good level accuracy to 67 GHz
- Low noise floor: -152 dBm (1 Hz) at 2 GHz, -130 dBm (1 Hz) at 65 GHz
- Wide range of resolution bandwidth: 1 Hz to 50 MHz
- Versatile filter characteristics: Gaussian, channel filters, FFT, 6-dB EMI filters
- Full range of detectors including RMS, quasipeak
- Comprehensive power measurement functions (CP, ACP, time domain power)
- NRP power heads can be connected directly (Option FS-K9 and NRP-Z6 required)
- Harmonic distortion and spurious emissions measurement function
- High display linearity < 0.1 dB
- Phase noise and noise figure application firmware
- External generator control for use of an external microwave generator as tracking generator for scalar network measurements
- R&S® FSU3: DC coupled 20 Hz to 3.6 GHz AC coupled 1 MHz to 3.6 GHz
- R&S® FSU8: DC coupled 20 Hz to 8 GHz AC coupled 1 MHz to 8 GHz
- R&S® FSU26: DC coupled 20 Hz to 26.5 GHz AC coupled 10 MHz to 26.5 GHz
- R&S® FSU43: DC coupled 20 Hz to 43 GHz
- R&S® FSU46: DC coupled 20 Hz to 46 GHz
- R&S® FSU50: DC coupled 20 Hz to 50 GHz Frequency range
- R&S® FSU67: DC coupled 20 Hz to 67 GHz Frequency resolution 0.01 Hz
The Rohde & Schwarz R&S FSU67 Spectrum Analyzer surpasses the proven excellent RF data of the R&S FSE and R&S FSIQ series of Spectrum Analyzers. Measurements calling for an extremely wide dynamic range are simpler, faster and more reliable - in development, quality management and production environments.
The R&S FSU67 can rightly be called the new reference in spectrum analysis, with an unprecedented dynamic range:
- TOI >20 dBm, typ. +25 dBm
- 1 dB compression (0 dB RF attenuation): +13 dBm
- Displayed average noise level: -158 dBm (1 Hz bandwidth)
- 77 dB ACLR typ. for 3GPP, 84 dB typ. with noise correction
- HSOI 55 dBm typ.
- Phase noise: -160 dBc/Hz typ. at 10 MHz carrier offset
The R&S FSU series of spectrum analyzers launched with the most abundant functionality available on the spectrum analyzer market. All major functions come straight away in the basic unit and include:
- Highly selective digital filters from 10 Hz to 100 kHz
- Fast FFT filters from 1 Hz to 30 kHz
- Channel filters from 100 Hz to 5 MHz
- RRC filters
- 1 Hz to 50 MHz resolution bandwidth
- QP detector and EMI bandwidths 200 Hz, 9 kHz, 120 kHz
- 2.5 ms sweep time in frequency domain
- 1 µs sweep time in time domain
- Number of measurement points/trace selectable between 155 and 10001
- Time-selective spectrum analysis with gating function
- GPIB interface, IEEE 488.2
- RS-232-C serial interface, 9-pin SUB-D connector
- VGA output, 15-pin SUB-D
- PC-compatible screenshots on diskette or hard disk
- Up to 20 measurements/s in manual mode
- Up to 30 measurements/s on GPIB interface
- SCPI-compatible GPIB command set
- R&S FSE R&S FSIQ compatible GPIB command set
- Fast ACP measurement in time domain
- Statistical signal analysis with CCDF function
- RMS detector of 100 dB dynamic range
- Transducer factor for correcting antenna or cable frequency responses
- 2-year calibration cycle
- External reference from 1 MHz to 20 MHz in 1 Hz steps
- GGSM/EDGE modulation measurements (with option R&S FS-K5)
| Option Code | Description |
|---|---|
| B12 | Output attenuator for tracking generator for FSU, FSQ |
| B18 | Removable Hard Disk (not retrofittable) |
| B19 | Second Hard Disk for FSU-B18 (for FSU-B18,variant 1303.0400.02) |
| B20 | Extended environment specification. Random vibr. 1.9G RMS, 0-55°C (not retrofittable) |
| B21 | LO/ZF connections for external mixers (for FSQ26, FSQ40,FSU26, FSU43, FSU46, FSU50) |
| B24 | Preamplifier 30dB, 100 kHz to 50GHz (for FSMR26/43/50, FSQ26/40, FSU26/43/46/50; |
| B25 | Electronic attenuator 0 to 30 dB, Preamplifier 20 dB, 10MHz - 3.6 GHz for FSU, FSQ |
| B27 | FM output, 10 MHz bandwidth |
| B4 | OCXO 10 MHz aging/year: 0.35*10E-7 for FSU, FSQ, FSMR |
| B5 | Output for low phase noise 640MHz reference signal for FSU3, FSU8, FSQ3 und FSQ8 |
| B73 | Vector signal analysis for FSU demodulation bandwidth 8 MHz (FSU), broadband demodulation hardware included |
| B9 | Tracking generator for FSU and FSQ, 100 kHz - 3.6 GHz |
| C3 | THREE YRS OF DEPOT FACTORY STANDARD CALIBRATION BASED ON THE R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY WITH 2 ADDITIONAL DEPOT CALIBRATION(S). |
| C5 | THREE YRS OF DEPOT FACTORY STANDARD CALIBRATION BASED ON THE R&S RECOMMENDED CALIBRATION INTERVAL - INCLUDES TEST DATA. THE FIRST CALIBRATION IS INCLUDED WITH PRODUCT DELIVERY WITH 2 ADDITIONAL DEPOT CALIBRATION(S). |
| DCV-2 | Documentation of calibration values |
| DCV-ZP | Printout of DCV (additional, in combination with DCV-Option only) |
| DKD | FSU67 DKD (ISO17025) calibration incl. ISO 9000 calibration (order only with device) |
| FS-K10 | GSM/EDGE/EDGE Evolution Measurement Appl (for FSG/FSQ/FSU) |
| FS-K15 | VOR/ILS measurements for FSMR |
| FS-K30 | Application firmware for noise figure and gain measurements for FSMR, FSP, FSQ, FSU |
| FS-K40 | Application firmware for phase noise measurements for FSMR, FSP, FSQ, FSU |
| FS-K5 | Application firmware GSM/EDGE tests for FSP, FSU, FSQ |
| FS-K5U | Upgrade of FS-K5 to FS-K10, GSM/EDGE/EDGE Evolution Measurement Appl (for FSG, FSQ, FSU) |
| FS-K7 | FM demodulator, allows measurement of FM specific parameters (for FMU, FSP, FSU) |
| FS-K72 | Application firmware 3GPP-FDD BTS transmitter test for FSMR, FSP, FSU, FSQ |
| FS-K73 | Application firmware 3GPP-FDD UE transmitter test for FSMR, FSP, FSU, FSQ |
| FS-K73+ | 3GPP HSPA+ UE transmitter test, application firmware (for FSMR, FSP, FSQ, FSU, FSUP, |
| FS-K74 | 3GPP HSDPA base station test application firmware for FSMR, FSU, FSP, FSQ |
| FS-K74+ | 3GPP HSPA plus, base station test. Application firmware (for FSP, FSQ, FSU, FSG; |
| FS-K76 | 3GPP TD-SCDMA base station test; application firmware for FSMR, FSP, FSQ, FSU |
| FS-K77 | 3GPP TD-SCDMA mobile station test; application firmware for FSMR, FSP, FSQ, FSU |
| FS-K8 | Application firmware for Bluetooth measurement on FSP, FSU and FSQ |
| FS-K82 | CDMA2000/1xEV-DV base station test application firmware for FSMR, FSP, FSU, FSQ |
| FS-K83 | CDMA2000/1xEV-DV mobile station application firmware for FSMR, FSP, FSQ, FSU |
| FS-K84 | 1xEV-DO base station test application firmware for FSMR, FSU, FSP, FSQ |
| FS-K85 | 1xEV-DO mobile station test application firmware for FSMR, FSP, FSQ, FSU |
| FS-K9 | Measurements with NRP power sensors NRP-Z11/Z21/Z22/Z23/Z24/Z51/Z55/Z91 requires NRP-Z3 or NRP-Z4 |
| FSP-B10 | External generator control for retrofit of FSP, FSU, FSQ, ESPI, ESCI |
| FSP-B28 | Trigger port for FSP,FSQ,FSU; for indication of trigger conditions |