EJA110A-DMS5A-22ND Yokogawa EJA110A Differential Pressure Transmitter
EJA110A-DMS5A-22ND Yokogawa EJA110A Differential Pressure Transmitter
- Users must consider the characteristics of selected wetted parts material and the influence of process fluids. The use of inappropriate materials can result in the leakage of corrosive process fluids and cause injury to personnel and/or damage to plant facilities. It is also possible that the diaphragm itself can be damaged and that material from the broken diaphragm and the fill fluid can contaminate the user's process fluids. Be very careful with highly corrosive process fluids such as hydrochloric acid, sulfuric acid, hydrogen sulfide, sodium hypochlorite, and high-temperature steam. Contact Yokogawa for detailed information of the wetted parts material.
- Indicates material of cover flanges and process connectors.
- Diaphragm material is Hastelloy C-276 or ASTM N10276. Other capsule wetted parts materials are SUSF316L, SUS316L or ASTM grade 316L.
- SUS316 or ASTM grade 316.
- For Capsule code L when combined with Wetted parts material code H, M, T, A, D, and B, the maximum working pressure is 3.5 MPa {35 kgf/cm2}.
- If necessary, specify Mounting bracket code C, D or K.
The EJA-A series is Yokogawa's most successful pressure transmitter line. First released in 1991, it continues to offer high
performance and high reliability for any application. With an installed base of over 4-1/2 million EJA-A transmitters worldwide, it
has a proven track record that makes it a true industry workhorse.
The EJA110A is the Traditional-mount Differential Pressure Transmitters in the series.
EJA110A features include:
- 0.065% Accuracy
- 0.1% Stability per 5 years
- 2,300 psi MWP
Model Number: EJA110A
-
Output: 4-20mA with HART protocol
-
Accuracy: ±0.065% of span
-
Cover Flange: SUS316, Hastelloy C-276, Monel
-
Power Supply: 10.5 to 42V
-
-
EJA110A Overview
| Measurement Types | |
| Primary Variable | Differential Pressure (DP) |
| Reference Accuracy | |
| Primary Variable | ±0.065% of DP Span |
| Long Term Stability (All Normal Operating Conditions) | |
| Primary Variable | M, H, or V Capsule: ±0.1% of URL per 5 years L Capsule: ±0.1% of URL for 1 year |
| Maximum Pressure Limit (MWP) | |
| All Capsules | 2,300 psi |
| Over-pressure Effect | |
| Primary Variable | ±0.03% of URL |
| Rangeability | |
| Primary Variable | M, H, or V Capsule: 100:1 L Capsule: 20:1 |
| Burst Pressure (Absolute) | |
| All Capsules | 10,000 osi |
Our advantage Products:
【Honeywell】Module DCS / PLC
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【Rosemount】Pressure and Temperature Transmitter
【Yokogawa】Pressure Transmitter
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
(Modicon,SMC,SICK,NORGREN,Siemens etc.)
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.