3BSE018103R1 ABB CI853K01 Dual RS232-C interface Redundant Power Supply Unit
*, *::before, *::after {box-sizing: border-box;}* {margin: 0;}html, body {height: 100%;}body {line-height: 1.5;-webkit-font-smoothing: antialiased;}img, picture, video, canvas, svg {display: block;max-width: 100%;}input, button, textarea, select {font: inherit;}p, h1, h2, h3, h4, h5, h6 {overflow-wrap: break-word;}ul, li, ol {padding: 0;list-style-position: inside;}.page-wrap {margin: 34px auto 0 auto;padding: 20px;color: #333;}.template1 h3:has(img)::after, .template2 h3:has(img)::after, .template3 h3:has(img)::after, .templat4 h3:has(img)::after, .templat5 h3:has(img)::after, .templat6 h3:has(img)::after {display: none !important;}.template1 h3 {color: rgb(0, 0, 0);font-size: 20px;font-weight: 700;line-height: 30px;margin-bottom: 6px;display: flex;margin-top: 22px;}.template1 .tit .tit-text {margin-right: 14px;font-size: inherit;font-weight: inherit;}.template1 h3:after {content: ;display: block;flex: 1;border-top: 1px dashed rgba(1, 1, 1, 0.8);position: relative;top: 17px;pointer-events: none;margin-left: 16px;}.template1 p {color: #333;font-size: 14px;font-weight: 400;line-height: 18px;}.template1 div {color: #333;font-size: 14px;font-weight: 400;line-height: 18px;margin-bottom: 6px;}.template1 ul, .template1 ol {font-size: 14px;font-weight: 400;line-height: 22px;list-style: decimal;}.template1 li span {color: #333;font-weight: normal;}.template1 table tr td, .template1 table tr th {padding: 4px;}li::marker {font-weight: normal;}.template1 table {border: 1px solid #333;width: 100%;border-collapse:collapse;}.template1 table td,.template1 table th {b 3BSE018103R1 ABB CI853K01 Dual RS232-C interface Redundant Power Supply Unit
Description
CI853 RS-232 module protocols:
COMLI can be used on the build in COM3 port and optionally on the CI853 ports. The cable length can be extended considerably (to several km) using a fiber optic converter. RS-232C is the standard communication interface used for serial communication with COMLI. The CI853 supports Hot Swap. COMLI is an ABB protocol for data transmission between controllers. It is designed for asynchronous master/slave communication in half-duplex. COMLI protocol supports dial-up modem controlled from the application. CI853 supports both Master/Slave mode in COMLI.
MODBUS RTU is a standard protocol widely spread because of its ease of use and reliability. Modbus RTU is an open, serial (RS-232 or RS-485) protocol derived from the Master/Slave architecture exchanging information in half duplex mode. The Modbus functionality can be configured both on the COM ports of AC 800M and CI853. Module Redundancy is not available in MODBUS RTU. CI853 supports only Master mode in MODBUS RTU.
General info
| Article number | 3BSE018103R1 (CI853K01) |
| Communication protocol | COMLI and MODBUS RTU |
| Master or slave | Master/Slave |
| Number of channels | 2 |
| Transmission speed | 75 - 19 200 b/s |
| Line redundancy | No |
| Module redundancy | No |
| Hot Swap | Yes |
| Used together with HI Controller | Yes |
Detailed data
| Max units on CEX bus | 12 |
| Connector | RJ-45 female (8-pin) |
| 24 V consumption typ. | 100 mA |
Environment and certification
| Temperature, Operating | +5 to +55 °C (+41 to +131 °F) |
| Temperature, Storage | -40 to +70 °C (-40 to +158 °F) |
| Corrosion protection | G3 compliant to ISA 71.04 |
| Protection class | IP20 according to EN60529, IEC 529 |
| CE- marking | Yes |
| Marine certificates | ABS, BV, DNV-GL, LR |
| RoHS compliance | DIRECTIVE/2011/65/EU (EN 50581:2012) |
| WEEE compliance | DIRECTIVE/2012/19/EU |
Dimensions
| Width | 59 mm (2.3 in.) |
| Height | 185 mm (7.3 in.) |
| Depth | 127.5 mm (5.0 in.) |
| Weight (including base) | 700 g (1.5 lbs) |
Features and benefits
- COMLI can be used on the build in COM3 port and optionally on the CI853 ports. RS-232C is the standard communication interface used for serial communication with COMLI. The CI853 supports Hot Swap. COMLI is an ABB protocol for data transmission between controllers.
- MODBUS RTU is an open, serial (RS-232 or RS-485) protocol derived from the Master/Slave architecture exchanging information in half duplex mode. The Modbus functionality can be configured both on the COM ports of AC 800M and CI853.
- Siemens 3964R can be used on the build in COM3 port and optionally on the CI853 ports. A standard RS-232C/485 communication channel is required.
- Self-defined Serial Communication can be used on the built in COM3 port (on an AC 800M Controller) and optionally on the CI853 ports.
- The CI853 module also supports Hot Swap.
FAQ:
Q: What is the brand name of the product?
A: The brand name of the product is ABB.
Q: What is the model number of the product?
A: The model number of the product is CI853K01 3BSE018103R1.
Q: Where is the product manufactured?
A: The product is manufactured in FI.
Q: What are the available payment terms?
A: The available payment terms are T/T, Western Union, and PAYONEER.
Q: What is the delivery time for the product?
A: The delivery time for the product is 3-5 days.
Wisdomlong Technology CO.,LTD Featured Products:
【Yaskawa】Servo Drive / Servo Motor
【Mitsubishi】Servo Drive / Servo Motor
【Honeywell】Module DCS / PLC
【Emerson】DeltaV Module / Servo Motor
【ABB】Input Output Module
【AB】Module / Touch Screen
【GE】IC69 Series PLC/ Fanuc Servo Motor and Drive
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.