Electric Fan Motor Axial Ceramic Case Resistor Type Temperature Fuse Thermal Cutoff Fuse

 

Structure
The thermal fuse is composed of ceramic shell, low melting point alloy wire, special resin, pin copper wire and sealing resin.

 

Apprearance
The marking must be clear; the sealing resin should fill the mouth and it is acceptable; the lead tin-plated layer is good; there is no oxidized black spot damage; the shell has no damage marks, perforations, etc.

 

No. Rated operating temperature
Tf(℃)
Hold temperature
Tc(℃)
Limit temperature Tm
(℃)
Measured operating temperature
(℃)
Rated voltage (V) Rated current
In(A)
Y20 115 87 150 112±3 250 2

 

Dimensions
a b c d
9.5±0.5 80±5 0.5±0.2 2.5±0.1

 

1A-20A Thermal Cutoff Fuses 0

 

Name Thermal Fuse     Applicable Standards  
Test items Unit Safety standard Testing equipment
Action temperature detection +0
TF
-10
thermotank
High pressure test V 1000+2 times the rated voltage Withstand voltage tester
Insulation resistance detection MΩ >2 Digital Megger
Internal resistance detection Ω <0.028 Bridge resistance tester
High pressure test after temperature check V >500 Withstand voltage tester
Insulation resistance test after temperature test MΩ >0.2 Digital Megger
Distortion detection Each lead is bent 90° at a distance of 10mm from the thermal fuse, and then twisted in the opposite direction by 180° without damaging the components. Manual operation

 

Experimental Method
The experimental conditions are temperature 25±10℃, humidity 65±15%M
1 Action humidity accuracy: Rely on the IE691: 1995 inspection method and measure with the built-in silicone oil pool in the thermostat.
2 Size: Measure the finished product with a micrometer/vernier ruler.
3 Appearance: visual inspection.
4 Insulation resistance: Measure the finished product with SP-3A digital megohmmeter, and measure the voltage DC500V.
5 Withstand voltage: Use the ZNY-12 withstand voltage test to determine the finished product, which takes 1 minute.
6 Tensile force: Measure the finished product with a push-pull tester, and the pin bears 1.5 pounds of pulling force for 10 minutes without damaging the components.
7 Torsion: Bend the lead at 10mm at 90°C, and then reverse it at 180°C without damaging the component.

 

Test Requirements
1. Rated operating temperature (Tf): The temperature at which the thermal fuse is tested according to the standard method to change its conductive state. (The Japanese Electrical Appliances Management Law stipulates that the tolerance range is ±7℃ for operation).

2. Measured operating temperature: The temperature fuse is heated in the silicone oil bath at a rate of 0.5-1°C per minute, and the fusing temperature obtained when the detection current is less than 100MA. It is the actual temperature of the thermal fuse.

3. Holding temperature (Tc): The maximum temperature at which the thermal fuse can maintain 168 hours without changing its conductive state when passing the rated current.

4. Limit temperature (Tm): The maximum temperature at which the thermal fuse can withstand 10 minutes without reconnection.

5. Rated voltage (Ur): The highest working voltage of the thermal fuse.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Dongguan Linkun Electronic Technology Co., Ltd.
Location Room 101, No. 21, Huayuanzai Road, Chongmei, Chashan Town, Dongguan City, Guangdong Province
Contact Person Huang

Request A Quote

Please check your email address.
Your message must be at least 20 characters.