300LPH Semiconductor Lab Water Filter Ultrapure Reverse Osmosis Water Purification System
CJ-RON(300) Flow maximum ≥300L/H
Producing High Quality Sterile Ultra Pure Water In Semiconductor Industry
CJ-RON(300) Semiconductor Ultrapure Water System Custom Support
Product introduction
Designed specifically for the semiconductor industry, this semiconductor ultrapure water system is designed to provide exceptional high-purity water quality to meet the stringent requirements of semiconductor processes. Through advanced technology, we ensure that water quality meets the high standards of semiconductor manufacturing and provides a reliable water source for production lines. This semiconductor ultrapure water equipment has built-in efficient reverse osmosis membrane and advanced ionization technology to effectively remove trace impurities and ensure the best production environment. This ultrapure water system provides reliable support for semiconductor production, improving production efficiency and product quality.
Product advantages
- The semiconductor ultrapure water system is equipped with an intelligent control system to monitor water quality, temperature and pressure to ensure the stability of the production process.
- Built-in efficient sterilization technology ensures the sterility of water quality and meets the requirements of semiconductor technology.
- This ultrapure water system for semiconductor has a compact structure, takes up little space, and is easy to integrate into the semiconductor manufacturing process line. Ensure systems always meet high standards.
- Custom support
- LCD display screen
- 304 stainless steel
- UV sterilization lamp
- Automatic flushing
- Effective disinfection: Choose the appropriate disinfection mode to ensure that the tools are free of impurities and that there is no residual water after disinfection. For preventive disinfection based on microbial levels, water machines and pipelines can be disinfected every three weeks. The actual frequency is adjusted based on microbial levels. The combined use of disinfectants is more effective than using them alone.
- Control pollution: Strictly monitor dialysis water to ensure that the department environment complies with regulations and maintain appropriate temperature and humidity.
- Concentration testing: Concentration testing is performed during the disinfection process to ensure full disinfection, and residual amounts are subsequently detected to avoid affecting treatment. Conduct regular disinfection effectiveness assessments to keep bacteria and endotoxins within specified limits.
- Reasonable selection of disinfectants: Avoid damage to the dialysis machine. For hot water disinfection systems, pay attention to heater power and temperature range.
- Standardized operating procedures: Monitor the conductivity and flow rate of produced water every day to understand the performance of the membrane. Ensure that operating procedures and work processes are strictly standardized.
- Improvement of personnel quality: Emphasis on standardized operations and good hygiene habits of medical staff, and compliance with operating procedures.
| The water requirements | work relative humidity | barometric pressure | mains input | environment temperature |
|---|---|---|---|---|
| drinking water | ≤80% | 700KPa~1060KPa | three-phase supply:380V/ single-phase source:220V | 5℃~40℃ |
| Parameter | ||||
| Model | CJ-RON(300) | |||
| The amount of water produced | ≥300L/H | |||
| Operating pressure | 0.8-1.35 | |||
| Power | AC380/3.0/3.5/3.8/4.2/5.2 (It depends on the amount of water produced) | |||
| Total number of colonies | ≤10cfu/100ml(Aseptic water standard) | |||
| The output water quality | ≤2μs/cm(double stage Reverse osmosis configuration) | |||
| The output water quality | ≤10μs/cm(single stage Reverse osmosis configuration) | |||
| RO Removal Rate | ≥99% | |||
| Bacterial and endotoxin removal Rate | ≥99.9% | |||
![]() |
![]() |
![]() |
PLC programmable logic programIntelligent control program, with automatic operation, maintenance, flushing, and other advanced functions.
|
LCD touch screenThe PLC programmable program is used to realize intelligent control, and the LCD touch screen displays the running status in real-time and the running data.
|
Built-in thermal online printerAutomatic printing of water quality and system parameter records (optional)
|
![]() |
![]() |
![]() |
316 stainless steel316 stainless steel because of the addition of Mo element, so its corrosion resistance and high-temperature strength have
been greatly improved, high-temperature resistance can reach 1200-1300 degrees, and can be used under harsh conditions. |
Imported PES materialImported PES bacterial filter ensures that the water is truly sterile.
|
No dead cavity designThe reverse osmosis membrane shell is designed with no dead cavity to avoid the growth of fungi and control the reproduction of microorganisms by water quality.
|
| Parts that can be customized and selected | ||||
| Water Tanks | Pipes | Frame | Filter Housing | Memrane Housing |
| Filtering material | The system language | |||






Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.