High Voltage Switchgear Draw Out Cast Resin Dry Type Electrical Power Transformer IP54
High Voltage Switchgear Draw Out Cast ResinDry Type Electrical Power Transformer
Product Description
Components
• Preassembled substations mainly consist of:
- High voltage switchgear
- Distribution transformers
- Low voltage switchgear
- Protection devices
- Metering equipment
- Control systems
They integrate all these components within compact enclosures.
Construction
• The box bodies are made of materials like structural steel, aluminum alloys and flame retardant composites.
• They provide protection against weather, corrosion and intrusion.
• Internal components are factory assembled and tested before installation.
Applications
• Used for ring, dual power source or radial distribution systems.
• Suitable for:
- High-rise buildings
- Residential communities
- Industrial parks
- Mines and oilfields
- Temporary construction sites
Advantages
• Compact design with small footprint - around 1/10 to 1/5 of conventional substations.
• Lower investment and construction costs.
• Easy installation, operation and maintenance.
• High reliability and safety due to enclosed design.
• Mobility - Can be relocated when needed.
Specification
| Rated Voltage | 12/17.5/24kV | 36kV |
|
Standard applicable |
IEC 62271 – 202 (IEC 61330) | IEC 62271 – 202 (IEC 61330) |
| Normal ambient temperature | 40 ° C | 40 ° C |
| Maximum ambient temperature | 50 ° C | 50 ° C |
| Enclosure construction | Modular | Modular |
| Ventilation | Natural | Natural |
| Temperature class (Std.) | K 10 | K 10 |
| MV and LV compartment | IP 54 | IP 54 |
| Transformer compartment | IP 23 | IP 23 |
| Rated voltage (kV) | 12/24kV | 36kV |
| Power frequency (kV rms) | 28/50 | 70 |
| Impulse (kV p) | 75/125 | 170 |
| Rated frequency (Hz) | 50/60 | 50/60 |
| Rated normal current (A) | 630 | 630 |
| Breaking capacity (A) | 630 | 630 |
| Making capacity (kA) | 52.5 / 40 | 50 |
| Rated normal current (A) | 630 | 630 |
| Breaking capacity (kA) | 21/16 | 20 |
| Making capacity (kA) | 52.5 / 40 | 50 |
| Rated power (kVA) – oil type | 2500 | 2000 |
| Rated power (kVA) – Dry type | 2500 | 2000 |
| Rated secondary voltage (V) | 433 | 433 |
| Vector group | Dyn 11 | Dyn 11 |
| Tapping range | + 5 in steps of 2.5% | + 5 in steps of 2.5% |
| IP | Yes | Yes |
| Internal arc | Yes | Yes |
| Enclosure class | Yes | Yes |
| Impact test | Yes | Yes |
| Short circuit test on earthing | Yes | Yes |
Advantages
1.Excellent quality
2.24 hour service
3.Professional design
4.Advanced technique
5.Rapid delivery
Design
Engineering
1.Power generation plants
2.Substations
3.Commercial buildings
4.Data centers
5.Renewable energy systems
6.Transportation
Get in Touch