SF6 Air Insulated Metal Clad Power Compact Transformer Substation Uses SCADA

Price Negotiable
Price: 999 - 9999 USD
MOQ: 1
Delivery Time: 15 Working Days
Brand: Bosun
Product Description

SF6 Air Insulated Metal Clad Impact Test Power Distribution Transformear

 

 

Product Description

 

Control systems

 

• Local control involves operators manually operating equipment at the substation.

• Remote control uses SCADA and communication systems to operate the substation from a control center.

• Automatic control employs relays, logic controllers and processors to regulate operations with minimal operator intervention.

 

Protection systems

 

• Overcurrent protection uses fuses and circuit breakers to detect and interrupt fault currents.

• Differential protection compares currents at the two ends of a transmission line or transformer to detect internal faults.

• Directional protection determines the direction of a fault to selectively isolate the affected section.

• Distance protection monitors impedance to detect faults at a certain distance from the substation.

 

Faults and failures

 

• Insulation failure is a major cause of faults and outages in substations. It can occur due to overvoltage, excess heat, contamination, etc.

• Temporary overvoltages from lightening, faults and switching can damage insulation if adequate arresters are not provided.

• Overloading of lines and equipment beyond their ratings can cause damage, overheating and failure.

• Human error during maintenance and ops can also lead to equipment damage and outages.

• Fires are a significant hazard in substations due to the presence of flammable insulating oil and other combustible materials.

 

Specification

 

 

Rated Voltage 12/17.5/24kV 36kV

 

Standard applicable

IEC 62271 – 202 (IEC 61330) IEC 62271 – 202 (IEC 61330)
Normal ambient temperature 40 ° C 40 ° C
Maximum ambient temperature 50 ° C 50 ° C
Enclosure construction Modular Modular
Ventilation Natural Natural
Temperature class (Std.) K 10 K 10
MV and LV compartment IP 54 IP 54
Transformer compartment IP 23 IP 23
Rated voltage (kV) 12/24kV 36kV
Power frequency (kV rms) 28/50 70
Impulse (kV p) 75/125 170
Rated frequency (Hz) 50/60 50/60
Rated normal current (A) 630 630
Breaking capacity (A) 630 630
Making capacity (kA) 52.5 / 40 50
Rated normal current (A) 630 630
Breaking capacity (kA) 21/16 20
Making capacity (kA) 52.5 / 40 50
Rated power (kVA) – oil type 2500 2000
Rated power (kVA) – Dry type 2500 2000
Rated secondary voltage (V) 433 433
Vector group Dyn 11 Dyn 11
Tapping range + 5 in steps of 2.5% + 5 in steps of 2.5%
IP Yes Yes
Internal arc Yes Yes
Enclosure class Yes Yes
Impact test Yes Yes
Short circuit test on earthing Yes Yes

 

 

Team Show

 

 

1.Professional team

 

2.Comprehensive services

 

3.Strict quality control

 

4.Comprehensive inspection

 

5.Responsibility guarantee

 

 

Engineering

 

1.Power generation plants

 

2.Substations

 

3.Commercial buildings

 

4.Data centers

 

5.Renewable energy systems

 

6.Transportation

 

 

Why Choose Us

 

 

 

1.Our Expertise

 

2.Quality Products/Services

 

3.Competitive Pricing

 

4.Innovation

 

6.Possibles

 

7.Authorization by ABB Schneider Siemens

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Chongqing Bosun Electrical Co., Ltd.
Location No.18 Shigui Avenue, Jieshi Town, Banan District, Chongqing,China
Contact Person Shirley

Request A Quote

Please check your email address.
Your message must be at least 20 characters.