Electrodeionization EDI Module Designed for Continuous Water Purification and High Ion Selectivity in Industrial Applications
CEDl MODULE SERIES
CEDI | CEDI Electrodeionization for WWTP & ETP
Product Overview
DUBHE Industrial grade CEDI module offer higher reliability and better desalination performance than conventional film blocks. Using a newly designed ion exchange membrane and patented flow channel technology, the desalination efficiency and antioxidant capacity aresignificantly ahead of similar products. Over the years, the research and development of ion exchange membrane technology has been insisted on as the core, relying on powerful ion exchange application technology, and the performance limits of various series of products have been constantly refreshed. Great improvements have been made to the ion exchange membrane on the basis of the traditional process, so the full range of CEDI modules have very excellent chemical cleaning resistance and high ion selectivity. Currently, it is one of the few CEDI manufacturers with independent research and development and design of ion membranes.
Features & Advantages
- Wide PH chemical cleaning,high reliability,long Life design.
- CPVC production of runner plate frame, high Weather resistance,long life design.
- Double O-ring sealing technology for double Injection to prevent leakage.
- 2 in2 out design,can directly replace the Traditional ordinary runner products.
- Specially designed ion exchange membrane, Extremely high ion selectivity, can achieve a large Flow in a limited volume to produce high purity water.
- Designed service life of more than 50,000 hours.
Applications
- Precision Optics
- Microelectronics
- Semiconductors
- Advanced Laboratories (Ultrapure Substance Analysis, Trace Substance Analysis)
- General industrial desalted water, high purity water
Technical Specifications
(General industrial desalted water, high purity water)
|
Item
|
GF - MK30 - 5
|
GF - MK40 - 5
|
GF - MK50 - 5
|
GF - MK60 - 5
|
GF - MK70 - 5
|
|
DC Voltage(V,DC)
|
0 -400
|
0 -400
|
0 -400
|
0 -400
|
0 -400
|
|
DC Current(A,DC )
|
2.0-5.0
|
2.0-5.0
|
2.0-5.0
|
2.0-5.0
|
2.0-5.0
|
|
Recommended feed (PH)
|
8.0 ±0.25
|
8.0 ±0.25
|
8 .0 ±0.25
|
8 .0 ±0.25
|
8 .0 ±0.25
|
|
Feed pressure(bar )
|
1.4-7
|
1.4-7
|
1.4-7
|
1.4-7
|
1.4-7
|
|
Operating temperature(℃)
|
5-45
|
5-45
|
5-45
|
5-45
|
5-45
|
|
Normal flow pressure Difference(bar)
|
1.4-3.0
|
1.4-3.0
|
1.4-3.0
|
1.4-3.0
|
1.4-3.0
|
|
Flow rate( m 3 / h )
|
Max:3 . 3
Standard:3 .0
Min:1 . 5
|
Max:4 .4
Standard:4 .0
Min:2 .0
|
Max::5. 5
Standard: 5 .0
Min :2. 5
|
Max:6 . 6
Standard:6 .0
Min:3 .0
|
Max:8 .0
Standard:7 .0
Min:3 . 5
|
|
Recovery rate(%)
|
90-95
|
90-95
|
90-95
|
90-95
|
90-95
|
|
Polar water
flow( L/hr)
|
80 - 120
|
80- 120
|
80 - 120
|
80 - 120
|
80 - 120
|
|
Water production resistivity ( MΩ .cm )
|
≥ 16
|
≥ 16
|
≥ 16
|
≥ 16
|
≥ 15
|
|
TOC Removal Rate
(Depending on feed water)(PPM )
|
>90
|
>90
|
>90
|
>90
|
>90
|
|
Silica (SiO2) Removal Rate (Depending on feed water)
|
90 -99.0
|
90-99.0
|
90 -99.0
|
90 -99.0
|
90 -99.0
|
|
Na+ Removal Rate
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
|
CL- Removal Rate
|
>99%
|
>99%
|
>99%
|
>99%
|
>99%
|
|
Dimensions
(L*W*H)(mm)
|
570*315*608
|
730*315*608
|
810*315*608
|
865*315*608
|
865*315*608
|
|
Fixed center distance ( mm )
|
Crosswise:215
Portrait:430
|
Crosswise:215
Portrait: 590
|
Crosswise:215
Portrait: 670
|
Crosswise:215
Portrait: 72
|
Crosswise:215
Portrait: 725
|
|
Operating weight ( KG)
|
90
|
121
|
136
|
147
|
156 |
|
Item
|
GF- UPW - B10
|
GF- UPW - B20
|
GF- UPW - B30
|
GF- UPW - B40
|
GF- UPW - B50
|
|
DC Voltage(V,DC)
|
0 -400
|
0 -400
|
0 -400
|
0 -400
|
0 -400
|
|
DC Current(A,DC )
|
2 .0-5.0
|
2 .0-5.0
|
2 .0-5.0
|
2 .0-5.0
|
2 .0-5.0
|
|
Recommended feed(PH)
|
7 .5-9.0
|
7 .5-9.0
|
7 .5-9.0
|
7 .5-9.0
|
7 .5-9.0
|
|
Feed pressure(bar )
|
2 .0-7
|
2 .0-7
|
2 .0-7
|
2 .0-7
|
2 .0-7
|
|
Operating temperature (℃)
|
20 -45
|
20 -45
|
20 -45
|
20 -45
|
20 -45
|
|
Normal flow pressure |
1 .4-2 .8
|
1 .4-2 .8
|
1 .4-2 .8
|
1 .4-2 .8
|
1 .4-2 .8
|
|
Flow rate( m3 /h )
|
Max :1 . 2
Standard :1 .0
Min :0 .4
|
Max :2 . 2
Standard :2 .0
Min :1 . 2
|
Max :3 . 3
Standard :3 .0
Min :1 . 6
|
Max :4 .4
Standard :4 .0
Min :2 .0
|
Max :5 . 5
Standard :5 .0
Min :2 .4
|
|
Recovery rate(%)
|
90-95
|
90-95
|
90-95
|
90-95
|
90-95
|
|
Polar water flow ( L/hr)
|
80 - 120
|
80 - 120
|
80 - 120
|
80 - 120
|
80 - 120
|
|
Water production resistivity (MΩ.cm )
|
≥ 17
|
≥ 17
|
≥ 17
|
≥ 17
|
≥ 17
|
|
TOC Removal Rate
(Depending on feed water)(PPM)
|
>95%
|
>95%
|
>95%
|
>95%
|
>95%
|
|
Silica (SiO2) Removal Rate (Depending on feed water)
|
90 -99.0
|
90 -99.0
|
90 -99.0
|
90 -99.0
|
90 -99.0
|
|
Boron Removal Rate %
|
90 -99.0
|
90 -99.0
|
90 -99.0
|
90 -99.0
|
90 -99.0
|
|
Na+ Removal Rate
|
>99 .9 %
|
>99 .9 %
|
>99 .9 %
|
>99 .9 %
|
>99 .9 %
|
|
CL- Removal Rate
|
>99 .9 %
|
>99 .9 %
|
>99 .9 %
|
>99 .9 %
|
>99 .9 %
|
|
Dimensions(L*W *H)(mm)
|
363 * 315* 608
|
497 * 315 * 608
|
630 * 315 * 608
|
710 * 315 * 608
|
830 * 315 * 608
|
|
Fixed center distance ( mm )
|
Crosswise:215
Portrait:243
|
Crosswise:215
Portrait:377
|
Crosswise:215
Portrait:510
|
Crosswise:215
Portrait :590
|
Crosswise:215
Portrait:710
|
|
Operating weight ( KG)
|
52
|
78
|
104
|
119
|
142
|
Selection Parameters
|
Model
|
(m³/h)MAavimumElowRate
|
(m³/h)StandardFlowRate
|
(m³/h)MinFlowRate
|
(mm)Dimensions
(L*W*H)
|
(mm)FixedCenterDistanceW1L1
|
(KG)ProductNetWeight
|
|
|
GF-DF05
|
0.67
|
0.50
|
0.22
|
202*315*660
|
215
|
172
|
41
|
|
GF-DF10
|
1.65
|
1.10
|
0.55
|
280*315*660
|
215
|
245
|
54
|
|
GF-DF20
|
3.10
|
2.00
|
1.10
|
387*315*660
|
215
|
357
|
76
|
|
GF-DF30
|
5.10
|
3.30
|
1.65
|
572*315*660
|
215
|
540
|
105
|
|
GF-DF50
|
7.67
|
5.10
|
2.55
|
785*315*660
|
215
|
757
|
150
|
|
GF-DF80
|
10.00
|
8.00
|
3.50
|
918*315*660
|
215
|
893
|
176
|
Need a quotation for your EDI project?
Send us your reactor volume, COD/NH4-N load and target effluent standard. Contact us today for a EDI solution.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.