High Precision Laser Power Meters 2mW-15W 10mW-50W 0.5W-100W 100uW-5W
2mW-15W, 10mW-50W, 0.5W-100W, 100uW-5W Laser Power Meters
Laser power meter is used to measure laser power and power stability. We have designed several laser power measurement instruments with the features of accuracy testing, easy operation, etc., which could fully meet customer’s practical needs of laser power and power stability measurement. They are widely used in the research, teaching, medical science, industry and other fields.
| Product | Part number | Power range | Main features | |
|
Thermopile Laser Power Meter |
STC-TS series (Wide Range) |
STC-TS2+TP100 | 2mW-2W | 1.Wavelength range: 0.19 -20µm 2. Damage threshold: 15kW/cm2 3. Power measurement range:2mW-15W 4. Sensitivity diameter: 14mm 5. Minimum measuring precision:0.1mW |
| STC-TS5+TP100 | 5mW-5W | |||
| STC-TS15+TP100 | 10mW-15W | |||
| STC-TS35+TP100 | 10mW-35W | 1. Wavelength range: 0.19 -25µm 2. Damage threshold: 40kW/cm2 3. Power measurement range: 10mW-50W 4. Sensitivity diameter: 22mm 5. Minimum measuring precision: 0.001W |
||
| STC-TS50+TP100 | 10mW-50W | |||
| STC-TS100+TP100 | 0.5W-100W | 1. Wavelength range: 0.19 -20µm 2. Damage threshold: 45kW/cm2 3. Power measurement range: 0.5W-100W 4. Sensitivity diameter: 25mm 5. Minimum measuring precision: 0.001W |
||
| STC-HS series (High Precision) |
STC-HS1+TP100 | 100µW-1W | 1. Wavelength range: 0.19 -15µm 2. Damage threshold: 1.5kW/cm2 3. Power measurement range: 100µW-5W 4. Sensitivity diameter: 8.5mm 5. Minimum measuring precision: 0.01mW |
|
| STC-HS5+TP100 | 500µW-5W | |||
| Hand-held series | STC-HP2 | 10mW-20W | 1.Wavelength range: 0.19-25µm
2.Damage threshold: 40kW/cm2 3.Powe measurement range: 10mW-50W 4.Sensitivity dia.: 22mm |
|
| STC-HP5 | 0.5W-50W | |||
| USB series (multi-channel) |
STC-PD100-350-USB STC-PD1000-350-USB STC-PD100-350T-USB STC-PD1000-350T-USB STC-PD20-200-USB STC-PD1000-200-USB STC-PD20-200T-USB STC-PD1000-200T-USB PD3000-350-USB |
1nW-100mW
1nw-1W 1nW-100mW 1nw-1W 1nw-20mW 1nw-1W 1nw-20mW 1nw-1W 1uW-3W |
1. Wavelength range:0.19 -25µm 2. Power range: 1µW-200W 3. Single channel/ multiple channel power measurement 4. PC upper computer software display measurement 5. RS232, RS422 or other communication interface can be customized |
|
| STC-TS2/ TS5/ TS15-USB STC-TS35/ TS50-USB STC-TS100-USB STC-HS1/ HS5-USB |
100µW-100W | |||
|
Photoelectric Laser Power Meter |
STC-PS100 series (High Precision) |
STC-PS100 | 2nW-100mW | 1. Wavelength range: 320-1100nm 2. High precision: ±2% 3. Resolution: 2nW 4. Minimum measuring precision: 0.001nW |
1. STC-TS+TP100 Series Laser Power Meter (2mW-15W)
-
Wavelength range: 0.19 -20µm
-
Damage threshold: 15kW/cm2
-
Power measurement range: 2mW-15W
-
Sensitivity diameter: 14mm
-
Minimum measuring precision: 0.1mW
-
SMA905/FC fiber switch connector (Optional)
| Part number | STC-TS2+TP100 | STC-TS5+TP100 | STC-TS15+TP100 |
| Header Model | STC-TP100 | STC-TP100 | STC-TP100 |
| Probe Model | STC-TS2 | STC-TS5 | STC-TS15 |
| Power Range | 2 mW - 2 W | 5 mW - 5 W | 10 mW - 15 W |
| Sensitive Diameter | 14 mm | 14 mm | 14 mm |
| Continuous Measurement Time (<5W) | Unlimited (<2W) | Unlimited | Unlimited |
| Continuous Measurement Time (5-15W) | / | / | ≤8 min |
| Probe Coating Film | Broadband coating | ||
| Probe Material | Thermopile | ||
| Wavelength Range | 0.19-20 μm | ||
| Max. Average Power Density | 15 kW/cm2 | ||
| Sensitivity | 2 mW | 5 mW | 10 mW |
| Calibration Uncertainty (k=2) | ±2% | ||
| Response Time (0-90%) | <1 sec. | ||
| Linearity | ±1% | ||
| Power Supply | 18650 (2 batteries) | ||
| Overall Weight | 1.454 kg | ||
| Cooling Method | Air cooling | ||
| Computer Interface | USB 1.1 and USB 2.0 | ||
| Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A | ||
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | ||
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) | ||
2. STC-TS+TP100 Series Laser Power Meter (10mW-50W)
-
Wavelength range: 0.19 -25µm
-
Damage threshold: 40kW/cm2
-
Power measurement range: 10mW-50W
-
Sensitivity diameter: 22mm
-
Minimum measuring precision: 0.001W
-
SMA905/FC fiber switch connector (Optional)
| Part Number | STC-TS35+TP100 | STC-TS50+TP100 |
| Header Model | STC-TP100 | STC-TP100 |
| Probe Model | STC-TS35 | STC-TS50 |
| Power Range | 10 mW - 35 W | 10 mW - 50 W |
| Sensitive Diameter | 22 mm | 22 mm |
| Continuous Measurement Time (<10 W) | Unlimited | Unlimited |
| Continuous Measurement Time (10-50W) | ≤5 min (10-35W) | ≤5 min (10-50W) |
| Probe Coating Film | Broadband coating | |
| Probe Material | Thermopile | |
| Wavelength Range | 0.19-25 μm | |
| Max. Average Power Density | 40 kW/cm2 | |
| Sensitivity | 10 mW | |
| Calibration Uncertainty (k=2) | ±2% | |
| Response Time (0-90%) | <1 sec. | |
| Linearity | ±1% | |
| Power Supply | 18650 (2 batteries) | |
| Overall Weight | 1.926 kg | |
| Cooling Method | Air cooling | |
| Computer Interface | USB 1.1 and USB 2.0 | |
| Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A | |
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) | |
3. STC-TS+TP100 Series Laser Power Meter (0.5W-100W)
-
Wavelength range: 0.19 -20µm
-
Damage threshold: 45kW/cm2
-
Power measurement range: 0.5W-100W
-
Sensitivity diameter: 25mm
-
Minimum measuring precision: 0.001W
| Part Number | STC-TS100+TP100 |
| Header Model | STC-TP100 |
| Probe Model | STC-TS100 |
| Power Range | 0.5 W - 100 W |
| Sensitive Diameter | 25 mm |
| Continuous Measurement Time (<80 W) | 2 h |
| Continuous Measurement Time (80-100 W) | ≤8 min |
| Probe Coating Film | Broadband coating |
| Probe Material | Thermopile |
| Wavelength Range | 0.19-20 μm |
| Max. Average Power Density | 45 kW/cm2 |
| Sensitivity | 0.1 W |
| Calibration Uncertainty (k=2) | ±2% |
| Response Time (0-90%) | <7 sec. |
| Linearity | ±1% |
| Power Supply | 18650 (2 batteries) |
| Cooling Method | Fan cooling |
| Computer Interface | USB 1.1 and USB 2.0 |
| Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A |
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) |
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
4. STC-HS+TP100 Series Laser Power Meter (100uW-5W)
-
Wavelength range: 0.19 -15µm
-
Damage threshold: 1.5kW/cm2
-
Power measurement range: 100µW-5W
-
Sensitivity diameter: 8.5mm
-
Minimum measuring precision: 0.01mW
-
SMA905 fiber switch connector (Optional)
| Part Number | STC-HS1+TP100 | STC-HS5+TP100 |
| Header Model | STC-TP100 | STC-TP100 |
| Probe Model | STC-HS1 | STC-HS5 |
| Power Range | 100µW - 1 W | 500µW - 5 W |
| Sensitive Diameter | 8.5 mm | 8.5 mm |
| Probe Coating Film | Broadband coating | |
| Probe Material | Thermopile | |
| Wavelength Range | 0.19-15 μm | |
| Max. Average Power Density | 1.5 kW/cm2 | |
| Sensitivity | 100µW | 500µW |
| Calibration Uncertainty (k=2) | ±2% | |
| Response Time (0-90%) | <1 sec. | |
| Linearity | ±0.5% | |
| Power Supply | 18650 (2 batteries) | |
| Overall Weight | 1.434 kg | |
| Cooling Method | Air cooling | |
| Computer Interface | USB 1.1 and USB 2.0 | |
| Instrument Power | 100-240 VAC, 50/60 Hz, DC 12V-3.34A | |
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) | |
5. STC-TS-USB Series Laser Power Meter (2mW-15W)
-
Wavelength range: 0.19 -20µm
-
Power measurement range: 2mW-15W
-
Single channel/ multi-channel power measurement
-
PC upper computer software display measurement
| Model | STC-TS2-USB | STC-TS5-USB | STC-TS15-USB |
| Power Range | 2 mW - 2 W | 5 mW - 5 W | 10 mW - 15 W |
| Sensitive Diameter | 14 mm | 14 mm | 14 mm |
| Continuous Measurement Time (<5W) | Unlimited (<2W) | Unlimited | Unlimited |
| Continuous Measurement Time (5-15W) | / | / | ≤8 min |
| Probe Coating Film | Broadband coating | ||
| Probe Material | Thermopile | ||
| Wavelength Range | 0.19-20 μm | ||
| Max. Average Power Density | 15 kW/cm2 | ||
| Sensitivity | 2 mW | 5 mW | 10 mW |
| Calibration Uncertainty (k=2) | ±2% | ||
| Response Time (0-90%) | <1 sec. | ||
| Linearity | ±1% | ||
| Cooling Method | Air cooling | ||
| Computer Interface | USB 1.1 and USB 2.0 | ||
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | ||
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) | ||
6. STC-TS-USB Series Laser Power Meter (10mW-50W)
-
Wavelength range: 0.19 -25µm
-
Power measurement range: 10mW-50W
-
Single channel/ multi-channel power measurement
-
PC upper computer software display measurement
| Model | STC-TS35-USB | STC-TS50-USB |
| Power Range | 10 mW - 35 W | 10 mW - 50 W |
| Sensitive Diameter | 22 mm | 22 mm |
| Continuous Measurement Time (<10 W) | Unlimited | Unlimited |
| Continuous Measurement Time (10-50W) | ≤5 min (10-35W) | ≤5 min (10-50W) |
| Probe Coating Film | Broadband coating | |
| Probe Material | Thermopile | |
| Wavelength Range | 0.19-25 μm | |
| Max. Average Power Density | 40 kW/cm2 | |
| Sensitivity | 10 mW | |
| Calibration Uncertainty (k=2) | ±2% | |
| Response Time (0-90%) | <1 sec. | |
| Linearity | ±1% | |
| Cooling Method | Air cooling | |
| Computer Interface | USB 1.1 and USB 2.0 | |
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) | |
7. STC-TS-USB Series Laser Power Meter (0.5W-100W)
-
Wavelength range: 0.19 -20µm
-
Power measurement range: 0.5W-100W
-
Single channel/ multi-channel power measurement
-
PC upper computer software display measurement
| Part Number | STC-TS100-USB |
| Power Range | 0.5 W - 100 W |
| Sensitive Diameter | 25 mm |
| Continuous Measurement Time (<80 W) | 2 h |
| Continuous Measurement Time (80-100 W) | ≤8 min |
| Probe Coating Film | Broadband coating |
| Probe Material | Thermopile |
| Wavelength Range | 0.19-20 μm |
| Max. Average Power Density | 45 kW/cm2 |
| Sensitivity | 0.1 W |
| Calibration Uncertainty (k=2) | ±2% |
| Response Time (0-90%) | <7 sec. |
| Linearity | ±1% |
| Cooling Method | Fan cooling |
| Computer Interface | USB 1.1 and USB 2.0 |
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) |
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
8. STC-HS-USB Series Laser Power Meter (100uW-5W)
-
Wavelength range: 0.19 -15µm
-
Power measurement range: 100µW-5W
-
Single channel/ multi-channel power measurement
-
PC upper computer software display measurement
| Part Number | STC-HS1-USB | STC-HS5-USB |
| Probe Model | STC-HS1-USB | STC-HS5-USB |
| Power Range | 100µW - 1 W | 500µW - 5 W |
| Sensitive Diameter | 8.5 mm | 8.5 mm |
| Probe Coating Film | Broadband coating | |
| Probe Material | Thermopile | |
| Wavelength Range | 0.19-15 μm | |
| Max. Average Power Density | 1.5 kW/cm2 | |
| Sensitivity | 100µW | 500µW |
| Calibration Uncertainty (k=2) | ±2% | |
| Response Time (0-90%) | <1 sec. | |
| Linearity | ±0.5% | |
| Cooling Method | Air cooling | |
| Computer Interface | USB 1.1 and USB 2.0 | |
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | |
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) | |
9. STC-PS100 High Precision Photoelectric Laser Power Meter
-
Wavelength range: 320-1100 nm
-
High precision: ±2%
-
Resolution: 2nW
-
Minimum measuring precision: 0.001nW
| Part Number | STC-PS100 |
| Detector Model | STC-PD-MN-100 |
| Power Range | 2nW -100mW |
| Active Area Diameter | 8mm |
| Receiving Element | Si Photo diode |
| Wavelength Range | 320-1100 nm |
| Measurement Display | nW/ µW/ mW/ dBm/ dB |
| Calibration Uncertainty (k=2) | ±2% |
| Response Time (0-90%) | 0.2sec. |
| Total Weight | 0.8kg |
| Instrument Power | 100-240 VAC, 50/60 Hz, DC 9V-1.4A |
| Temperature (Operating) | 5℃-45℃ (41℉-113℉) |
| Temperature (Storage) | -20℃-70℃ (-4℉-158℉) |
10. Hand-held Laser Power Meter
Features:
-
Wavelength range: 0.19 -25µm
-
Power range: 10mW-2W, 0.5-50W
-
Active area diameter: 22mm
| Model | STC-HP2 | STC-HP50 |
| Power Range | 10mW - 2 W | 0.5W - 50 W |
| Active Area Diameter | 22 mm | 22 mm |
| Wavelength Range | 0.19-25 μm | 0.19-25 μm |
| Max. Average Power Density | 15 kW/cm2 | 40 kW/cm2 |
| Uncertainty (k=2) | ±2% | ±2% |
| Linearity | ±1% | ±1% |
| Cooling Method | Air cooling | Air cooling |
| Temperature (Operating) | 5°C - 45°C (41°F - 113°F) | 5°C - 45°C (41°F - 113°F) |
| Temperature (Storage) | -20°C - 70°C (-4°F - 158°F) |
-20°C - 70°C (-4°F - 158°F) |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.