12-30vdc Flush Diaphragm Pressure Sensor Wet Pressure Transducer For Measure Medium
BPHT24-III pressure transmitter
Introduction of Flush Diaphragm Pressure Sensor :
BPHT24-III pressure transmitter The signal processing circuit is located inside a stainless steel housing, converting the sensor signal into a standard output signal. This pressure transmitter is primarily used in places where high sanitary conditions are required, ensuring reliable and accurate pressure measurements in hygienic environments.
Product Features:
- Various pressure interface options
- Designed for hygienic applications to prevent medium scaling
- High accuracy with a fully stainless steel structure
- Easy to clean.
- Suitable for measuring non-corrosive gases and liquids with 316L
- Ideal for environmental protection and chemical industries
- Used in the marine and aviation industries
- Well-suited for use in the medical, biopharmaceutical, and food hygiene industries.
|
Performance Parameters: |
|
| Measurement Range | 0~35Kpa…~20MPa |
| Pressure Type | Gauge Pressure, Absolute Pressure, Sealed Pressure |
| Overload | ≤ 1.5 times of the rated range |
| Accuracy @ 25℃ | ±0.25% (Typical) ±0.5% (Maximum) |
| Repeatability& Hysteresis | 0.02%F.S(Typ.) 0.05%F.S(Max.) |
| Long-Term Stability | ±0.1%F.S/Year(Typ.) ±0.2%F.S/Year(Max.) |
| Zero Point Temperature Drift | ±0.02%F.S/℃(≤100KPa) ±0.01%F.S/℃(>100KPa) |
| Full Scale Temperature Drift | ±0.02%F.S/℃(≤100KPa) ±0.01%F.S/℃(>100KPa) |
| Frequency Response | 2.4Khz |
| Compensation Temperature | 0-70℃(≤10mpa,customizable) |
| Operating Temperature | -20℃~80℃ |
| Storage Temperature | -40℃~120℃ |
| Vibration | 10g,55Hz ~ 2kHz |
| Housing Material | 304,316L |
| Diaphragm Material | 316L |
| Insulation Resistance | 100MΩ 100VDC |
| Explosion-proof Rating | Ex db IIC T6 Gb |
| Protection Rating | IP65 |
| O-Ring Seal | Fluoro rubber |
| Weight | ~0.8kg |
| Output Signal | Supply Voltage | Output Type |
| 4~20mA | 12~30VDC | 2/3/4 wire |
| 0~10/20mA |
3 wire |
|
| 0/1~5V | ||
| 0/1~10V | ||
| 0.5~4.5V | 5VDC | |
| RS485 Communication Protocol | 3.6~30V / Battery | 4 wire |
![]() |
| Installation Tips: |
1. Should try to avoid installation in vibration, impact or high temperature environment, so as not to affect the accuracy of the measurement and the life of the equipment,
2. Keep the environment around the pressure transmitter clean, avoid dust, grease and other impurities into the equipment, affecting its normal operation;
3. Avoid pressure exceeding the rated range of the pressure transmitter to avoid damage to the equipment. If it is necessary to measure the pressure beyond the rated range, the pressure transmitter with the appropriate rated range should be selected;
4. Select the appropriate material according to the characteristics of the measured medium to prevent the corrosive effect of the medium on the pressure transmitter. In order to ensure the accuracy of the measurement,
5. It is recommended to calibrate the pressure transmitter regularly. The calibration period can be determined according to the use environment and requirements.
| Order Guide | ||||||||
| BP93420XX | Pressure Transmitter | |||||||
| Code | Outline Construction | |||||||
| IX | Display Pressure Transmitter | IIC/III | Industrial General/ Display Pressure Transmitter | |||||
| Measurement Range | 0~35Kpa…~20MPa | |||||||
| (0-X)Kpa or MPa | X: Indicates the Actual Measuring Range | |||||||
| Code | Power Supply | |||||||
| D1 | 24VDC | |||||||
| D3 | Other | |||||||
| Code | Output Signal | |||||||
| S1 | 4~20mADC | |||||||
| S2 | 1~5VDC | S6 | 0~10VDC | |||||
| Code | Pressure Connection | |||||||
| J1 | M20×1.5 | |||||||
| J2 | G1/2 | |||||||
| J3 | 1/2NPT | |||||||
| Code | Electrical Connection | |||||||
| B1 | Hirschmann | |||||||
| B2 | PG7 Plug | |||||||
| B3 | Sealed Cable Output | |||||||
| B4 | 2088 Industrial Casing | |||||||
| B5 | 2088 Industrial Casing with Display | |||||||
| B6 | Other | |||||||
| Code | Pressure Type | |||||||
| G | Gauge Pressure | |||||||
| A | Absolute Pressure | |||||||
| S | Sealed Reference Pressure | |||||||
| Q&A |
A: High precision, durability, and excellent performance. Customization available.
2. Q: Can I customize special specifications?
A: Yes, our engineers can tailor products to meet specific needs. We provide OEM and ODM service
3. Q: What is your production capacity?
A: Our manufacturing facilities can produce up to 30,000 pressure sensor transmitters per month, so we are fully capable of meeting the needs of large-scale orders. However, it is advisable to contact our sales team in advance to ensure smooth production and delivery scheduling.
4. Q: What's the typical delivery period?
A: 5~8 working day for standard models. Customized products may vary.
5. Q: How are the products priced? Any discounts?
A: Competitive pricing with discounts for bulk orders or long-term partners.
6. Q: What is the warranty of your products? And after-sales service?
A: Our warranty time is 24 months after shipment, and our after-sales will respond with your questions in 24hrs, remote instruction by PC network is always available.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.