HT-IQ Flush Mounted Sensor Clamp Tightly Sealed Diaphragm Pressure Transducer Silicon Pressure Sensor
HT-IQ Flush Mounted Sensor Clamp Clamp Tightly Sealed Diaphragm Pressure Transducer
HT-IQ Piezoresistive Silicon Pressure Sensor
Introduction of flush silicon pressure sensor:
HT - IQ pressure sensor is a kind of flushing diffusion silicon diaphragm pressure sensor.The clamp pressure sensor uses disposable silicone oil filling technology.Diaphragm feel pressure by silicone oil is passed to the chip, the compensation circuit will be corrected for pressure signal linear electrical signals. The card is tightly sealed to prevent scaling, unsanitary and adhesion. Widely used in food, medicine, wine and other health industries, generally suitable for measuring media may be contaminated occasions.Flat diaphragm clamping structure, easy installation and disassembly, easy cleaning.


Product Features of flush silicon pressure sensor:
- Advanced technology and 316L stainless steel case packaging.
- Temperature compensation and zero correction by thick film circuit.
- Excellent reliability, repeatability and stability.
- Rinse diaphragm structure for easy cleaning.
- Power Supply: ≤2mA DC (Typical 1.5mA DC)
- Input Impedance : 2.5KΩ~6KΩ
- Output Impedance: 2.5KΩ~6KΩ
- Electrical Connection: Gold-plated Kovar pins or 100mm high-temperature wires.
| Performance Parameters of flush diffused silicon pressure sensor: | |||||
| Measurement Range | Gauge(G) | 35KPa,100KPa,200KPa,350KPa,1000KPa,2000Kpa | |||
| Absolute(A) | 100KPaA,200KPaA,350KPaA,700KPaA,1000KPaA,2000KPaA | ||||
| Sealed(S) | 3500KPaS | ||||
| Typ | Max | Unit | |||
| NonLinearity | ±0.15 | ±0.3 | %F.S | ||
| Repeatability | 0.05 | 0.1 | %F.S | ||
| Hysteresis | 0.05 | 0.1 | %F.S | ||
| Zero Offset Output | 0±1 | 0±2 | mV | ||
| Full Scale Output | ≤20KPa | 50±10 | 50±30 | mV | |
| ≥35kPa | 100±10 | 100±30 | mV | ||
| Zero Offset Temp. Drift | ≤20KPa | ±1 | ±2 | %F.S | |
| ≥35kPa | ±0.5 | ±1 | %F.S | ||
| Full Scale Temp. Drift | ≤20KPa | ±1 | ±2 | %F.S | |
| ≥35kPa | ±0.5 | ±1 | %F.S | ||
| Compensated Temp. | ≤20KPa | 0~50 | ºC | ||
| ≥35kPa | 0~70 | ºC | |||
| Operating Temperature | -20~80 | ºC | |||
| Storage Temperature | -40~125 | ºC | |||
| Allowable Overload | Take the smaller value between 3 times the full scale or 120MPa | ||||
| Burst Pressure | 5X the full scale | ||||
| Long-term Stability | 0.2 % | F.S/Year | |||
| Diaphragm Material | 316L | ||||
| Insulation Resistance | ≥200MΩ 100VDC | ||||
| Vibration | No change under conditions of 10gRMS, 20Hz to 2000Hz | ||||
| Shock | 100g,11ms | ||||
| Response Time | ≤1ms | ||||
| O-ring Seal | Nitrile rubber or Fluoro rubber | ||||
| Filling Medium | Silicon Oil | ||||
| Weight | ~200g | ||||
| The parameters are tested under the following conditions: 1.5mA @25°C | |||||
| Outline Construction | |
| Dimension |
|

| Electrical connection and compensation |
![]() |
| Selection Examples |
| Ordering tips |
2. During the housing assembly process, ensure that it is vertically aligned and apply even pressure to avoid jamming or damaging the compensation plate.
3. If the medium under test is incompatible with the core diaphragm and housing material (316L), special instructions should be provided when placing the order.
4. Avoid pressing the sensor diaphragm with hands or sharp objects to avoid deformation or puncture of the diaphragm and damage to the core.
5. Keep the pressure port of the gauge core open to the atmosphere to prevent water, water vapor or corrosive media from entering the negative pressure chamber of the gauge core.
6. If there is any change in the pin, please refer to the label on the actual product.
| company |




| FQA |
.
.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.