Air Test Silicon Differential Pressure Transmitter Sensor For Industrial Transducer Pressure Sensor
Air Test Silicon Differential Pressure Transmitter Sensor For Industrial
BP101 Silicon Piezoresistive Pressure Sensor
Introduction of Differential Pressure Transmitter :
BP101 silicon piezoresistive differential pressure sensor is a kind of diffused silicon element with high stability. It is a compact differential pressure sensor specially designed for small range differential pressure, which has a remarkable effect on small gas pressure measurement.It is known for its excellent reliability, repeatability and stability, making it ideal for accurate gas pressure measurement.
Product Features of Differential Pressure Transmitter :
- Wide measurement range, 0~10KPa~200kpa.
- High reliability and excellent stability.
- Aerospace applications.
Applications of Differential Pressure Transmitter :
- Measurement of dry, non-corrosive gas pressures.
- Pneumatic control systems.
- Biomedical engineering for medical applications.
- HVAC (Heating, Ventilation, and Air Conditioning) contro.
- Aerospace testing for aviation-related purposes.
Electrical performance of Differential Pressure Transmitter :
- Power Supply: 5V DC
- Output:0.5-4.5VDC
-
Performance Parameters Measurement Range 0-10KPa,0~~~200KPa Pressure Type Differential Pressure Static pressure 2 times of the rated range Overload ≤ 1.5 times of the rated range Accuracy @ 25℃ ±0.5% (Typical), ±1% (Maximum) Zero Temperature Drift ±2.5%F.S/℃(Typical) ±3%F.S/℃(Maximum) Span Temperature Drift ±2.5%F.S/℃(Typical) ±3%F.S/℃(Maximum) Compensation Temperature 0-50℃ Operating Temperature -20℃~80℃ Storage Temperature -40℃~100℃ Housing Material Plastic Pressure connection φ5 air nozzle or customizable Protection Rating IP65
Ordering tips of Differential Pressure Transmitter
1. Pay attention to the fit between the core size and the transmitter housing during assembly to achieve the required airtightness
2. During the assembly of the housing, ensure it is aligned vertically and apply even pressure to avoid jamming or damaging the compensation plate.
3. If the measured medium is not compatible with the core diaphragm and the housing material (316L), special instructions should be provided when placing the order.
4. Avoid pressing the sensor diaphragm with hands or sharp objects to prevent damage to the core due to diaphragm deformation or piercing.
| Q&A |
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.