Medical GE Disposable Spo2 Probe

Price Negotiable
MOQ: 1 Box
Delivery Time: About one week
Brand: Med Accessories
Product Description

 

 

OEM Part Number References:

Manufacturer OEM REF#
Datex Ohmeda TS-AF-10 (Box of 10), TS-AF-25 (Box of 25),TS-AP-10 (Box of 10)TS-AP-25 (Box of 25),TS-PAW-10 (Box of 10)TS-PAW-25 (Box of 25),

Compatibility Monitor brands:

Manufacturer Model
Datex Ohmeda
Cardiocap/5, E-PRESTN, S/5 with E-series modules, S/5 with M-OSAT module, TruSignal, TuffSat, i4 with E-series modules,3775, 37xx Series, 3800, 3900, 3900P, 4700, 5250, AS/3 with M-OSAT module, CS/3 with M-OSAT module, Cardiocap/5, E-PRESTN
GE Healthcare > Corometrics
259
GE Healthcare > Critikon > Dinamap
ProCare B20, Procare B40,Carescape B650, Carescape V100

1. Product Name:

 

GE TruSignal adult,pediatric,infant,Neonate TS-AF-10 Disposable Spo2 Sensor

 

2.Technical Parameters

Red 660nm±3 mm;
Infrared 905nm±5 mm
The maximum selectable power is 5mW.
Accuracy range: SpO2 range (70%~100%) --- ±3%;
Pulse rate declared accuracy range: 30~245bpm, ±2bpm
Usage Specifications:
- Operating temperature: 0~40℃
- Operating humidity: 15~85%RH
- Operating hyperbaric pressure: 86~106kPa
- Storage and transportation temperature: -20~+55℃
- Storage and transportation humidity: 10~85%RH
- Storage and transportation hyperbaric pressure: 86~106kPa

 

3. operation instructions

The above tables list models of Med Accessories disposable sensors for the following four categories of patients: adult (weight greater than 30 kg ),pediatric(10-50 kg weight ),infant (3-20 kg weight ),and neonatal/adult ( weight less than 3 kg or greater than 40kg ). Select the sensor model number that matches the brand of oximeter you are using.

Match the sensor model with your brand of oximeter. A mismatch may cause patient injury, inaccurate measurements or equipment damage. Check the sensor
every 2 hours and reposition to an alternate location every 24 hours. Avoid application of the sensors to edematous or fragile tissue Excessive patient motion,
excessive ambient light, electromagnetic interference, dysfunctional hemoglobin, low perfusion, intra vascular dyes, finger nail polish and long or artificial finger
nails may affect the sensor performance and the accuracy of the measurement Do not use the sensor if it is damaged. Use of a damaged sensor could cause patient
injury or equipment failure. Note: The materials used in the manufacture of the sensor contain no natural latex protein. The materials have undergone extensive
biocompatibility testing. Further information is available upon request.

To apply the sensor
1.Connect the sensor cable to the adaptor cable that fits your oximeter. Then turn on the oximeter and verify proper operation
2.Select the sensor site on the patient. The preferred sensor sites are the index finger for adult and children, the great toe for infants, and on the foot belowthe toes for neonate.
3.Apply the sensor on the patient:Position the emitter and detector directly opposite each other.Apply the sensor firmly but not too tightly. And then fix the sensor with Velcro non-adhesive tape.
4.Visually monitor the sensor site to ensure the integrity of the skin.

 

 

 

 

 

 

 

 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Med Accessories Technology Dongguan Co., Ltd.
Location No.210,211,212,213,214,Building 1,No.12 Industry Western Road,SongShanHu,Dongguan,Guangdong,China.523808
Contact Person Carina

Request A Quote

Please check your email address.
Your message must be at least 20 characters.