CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture
CV-260 Endoscopy Processor With Automatic White Balance And Pre-Frozen Image Capture
CV-260 has HDTV output, adaptive IHb color enhancement, IHb value calculation, and pseudo-color display, structure enhancement, electronic zoom, real-time image color drift correction flash release, automatic aperture control, pre-frozen image capture, automatic white balance, and other features.
Parameters Of CV-260 Endoscopy Processor
-
Brand: Olympus
-
Type: Endoscopy System
-
Model: CV-260
-
Description: All medical equipment, new and used, is thoroughly inspected by our engineers to ensure complete functionality.
-
External Dimensions: 370*72*465 mm
-
Weight:9.2kg
-
Power consumption:150VA
-
Video signal output:HDTV,SDTV
-
Main functions:HDTV output, adaptive IHb color enhancement, IHb value calculation and pseudo-color display, structure enhancement, electronic zoom, color drift correction for live images flash release, automatic iris control, pre-freeze image capture, automatic white balance
Details Of CV-260 Endoscopy Processor
| cv-260External dimensions: | 370 x 72 x 465 mm ( W x H x D ) |
| Weight: | 9.2KG |
Recommendations for Endoscopic Maintenance and Care
- Do not place the endoscope together with other instruments and avoid touching other parts with the insertion part.
- Wait until the endoscope angle returns to the 0-degree state before pulling out.
- Since the insertion part is long, please be careful when cleaning and storing it, and be sure to confirm that it is not stuck beforehand.
- When sterilizing EVIS endoscopes with ethylene oxide, remove the waterproof cap; when sterilizing other endoscopes with ethylene oxide, put on the ETO cap.
- Wait until the endoscope angle returns to the 0-degree state, then pull out from the trocar needle and trocar.
- When adjusting the angle of the insertion part, the angle should not be smaller than the range indicated in the instruction manual.
- Please keep the sheath as straight as possible during operation.
- Hold the insert gently and handle it carefully when taking it out.
- Store the endoscopy equipment for sale in a dry and well-ventilated place at room temperature and in a clean condition.
The processor has a signal processing circuit that is provided with a digital signal processor. The digital processor generates a coarse video signal that is indirectly displayable on a video screen from image signals generated by a charge coupled device sensor .An auxiliary circuit has a correction circuit that generates another coarse video signal that is directly displayable on the video screen included for the following: (a) video endoscope (b) a camera for an endoscope.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.

