Corrugation Profiles Flow Arrangements Brazed Plate Condenser Multipurpose

Price Negotiable
Price: Negotiate/Competitive
MOQ: one wooden package
Delivery Time: Within 12 days
Brand: Tenkai
Product Description

Corrugation Profiles And Flow Arrangements Copper Brazed Plate Heat Exchanger

 

Instruction :

 

Safety Precautions: Before starting any work, ensure that the heat exchanger and surrounding area are safe and free from any potential hazards. Wear appropriate personal protective equipment (PPE) such as gloves and safety glasses.

 

Inspection: Inspect the copper plate heat exchanger for any signs of damage, corrosion, or leaks. Check for any debris or fouling on the plates that may affect heat transfer efficiency.

 

Shut Down and Isolation: Safely shut down the system and isolate the heat exchanger from the fluid flow. Close any valves or disconnect any connections to prevent the flow of fluids during maintenance.

 

Draining: Drain the fluid from the heat exchanger to a

safe disposal location. Follow proper procedures to avoid spills or contamination.

 

Disassembly: Carefully remove the tightening bolts or clamps that hold the plates together. Take note of the order and arrangement of plates for reassembly.

 

Cleaning: Clean the copper plates using appropriate methods such as chemical cleaning or mechanical scrubbing to remove any fouling or deposits. Follow the manufacturer's instructions or recommended cleaning procedures.

 

Inspection and Repair: Inspect the plates for any damages or deformations. Replace any damaged plates or gaskets with suitable replacements. Check for any signs of corrosion or erosion and address them accordingly.

 

Reassembly: Place the cleaned and repaired plates back into their original order and position. Ensure proper alignment and tightness of the plates. Reinstall the 

tightening bolts or clamps and secure them according to the manufacturer's specifications.

 

Testing: Perform a pressure test to ensure there are no leaks in the reassembled heat exchanger. Check for proper flow and pressure distribution across the plates.

 

System Start-up: Once the heat exchanger has been reassembled and tested, reconnect the fluid flow and start the system. Monitor the performance and temperature differentials to ensure proper operation.

 

 

TYPE   B(mm)  C(mm)  D(mm)  E(mm)  THICKNESS(mm)  WEIGHT(Kg) MAX FLOW (m3/h)  DESIGN PRESSURE(Mpa) 
UFP 10   77   42   155   119 9+1.25N 0.28+0.027N     4          3/4.5
UFP 20A   93   40   323   269 9+1.5N 1+0.09N     8          3/4.5
UFP 42A  121   68   332   279 10+1.53N 2.05+0.11N    18          3/4.5
UFP 62FA  120   63   527   470 10+1.98N 2.379+0.18N    18          3/4.5
UFP 62FB  120   63   527   470 10+1.98N 2.379+0.18N    18          3/4.5
UFP 95FA  182   92   609   519 12+2.05N 15+0.36N    42          3/4.5
UFP 95FB  182   92   609   519 12+2.05N 15+0.36N    42          3/4.5

 

 

Workshop :

 

 

 

Package Area : 

 

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Nanjing Tenkai Heat Exchanger Co.,Ltd
Location HONGYANG BLOCK XURIHUATING 16 BUILDING,9# DAQIAO NORTH ROAD,JIANGBEI NEW DISTRICT,NANJING,JIANGSU,CHINA
Contact Person Lee

Request A Quote

Please check your email address.
Your message must be at least 20 characters.