Cleanroom Wall & Ceiling Panels with Anti-static Coatings for GMP Spaces
Product Overview

Our interlocking cleanroom panel system creates an airtight, washable envelope that defines the clean zone. Available in 50mm and 60mm thicknesses with rockwool or PU core, each panel is factory-cut to your precise layout, complete with door openings, pass-throughs, and sealed windows. The highly durable anti-static and anti-bacterial surface withstands daily VHP and IPA wiping without degradation. Aligned to EU GMP Annex 1 requirements for cleanability, this system eliminates ledges, exposed fasteners, and silicone joints that can harbor contamination.

Cause

Wall and ceiling surfaces are the largest area inside any cleanroom, yet they’re often treated as an afterthought. Contaminated surfaces constantly shed particles; one poorly sealed joint can destroy the entire cleanroom’s pressurization scheme. Standard sandwich panels may delaminate under repeated H2O2 fogging, and cheap PVC coving cracks, becoming a microbial reservoir. If your quality audit finds peeling coatings, rust spots on cut edges, or floor-channel seal failures, you will receive a major observation and possible shutdown. The surface envelope must not only look clean — it must be proven cleanable and withstand a documented disinfection cycle log.

Solution

We supply a fully integrated envelope system. The panel core is rockwool (A1 fire-rated) or PIR, with a 0.5mm hot-dip galvanized steel face coated in a 25-micron anti-static polyester finish. Edges are interlocking and factory-sealed with co-extruded PVC gaskets, forming a flush, tool-hiding joint. All corners use injection-molded nylon R-coves with a 50mm radius, eliminating sharp 90° angles where dirt collects. Ceiling panels are walkable up to 1.5 kN/m² point load and accept integrated HEPA housings with gel-seal knife-edges. This seamless integration means you never apply a bead of silicone on-site.

Specifications
Parameter Specification
Panel Width 900mm, 1,000mm, 1,170mm (custom)
Core Material Rockwool (120kg/m³) or PIR foam
Steel Skin 0.5mm GI, polyurethane polyester coat 25µm
Fire Rating A2-s1,d0 (rockwool) / B-s2,d0 (PIR)
Surface Resistivity 1*10⁶ to 1*10⁸ Ω (anti-static)
Ceiling Load Point load >150kg (walkable ceiling)
Accessories Flush windows, pass-boxes, air transfer grilles
Joint Performance No-silicone seal, cleanroom grade gasket
Compliance EU GMP Annex 1, ISO 14644-4, FM 4880
Application
  • Grade A/B sterile manufacturing enclosures
  • Positive pressure weighing suites
  • Negative pressure containment rooms (API handling)
  • Controlled environment storage (25°C/60%RH)
  • OEM cleanroom expansion modules
  • Cell and gene therapy B/C processing suites
How It Works

Each panel uses a concealed double-eccentric lock; a hex key rotates the cam, pulling panels together with 0.5mm accuracy. The integrated gasket compresses uniformly to achieve a 0.01 μm-tight seal. Wall-floor junction: a U-shaped base channel is anchored to the epoxy floor; the panel sits inside and is capped with a snap-on cove profile. The ceiling grid suspends from the slab, and gel-seal HEPA housings dock into ceiling panels. This tool-less ceiling design allows filter replacement from above without entering the cleanroom.

How To Choose

Define the required fire rating first: rockwool for A2, PIR for budget but B-s2. Choose surface coating based on disinfection — VPHP requires polyester, not PVC. Evaluate door frequency: high-traffic corridors need 1,200mm wide sliding doors with motion sensors. Confirm ceiling load if you intend to service HEPA filters from above. We recommend a free site survey; we measure floor flatness and slab irregularities to tailor base channel shimming and avoid gaps during assembly.

FAQ

Q1: Can you match existing panel colors?

A: Yes, our standard is cleanroom white, but we offer RAL custom colors for the outer face of walls. The clean-side always remains pure white for reflectivity.

Q2: How do you pass services through the panels?

A: Pre-fabricated service panels with embedded conduits and sealed cable entry boots. No site drilling is needed, protecting the warranty and cleanability.

Q3: Are the panels reusable?

A: Absolutely. The mechanical locking system enables complete disassembly and reinstallation in a new facility, a major sustainability advantage.

Q4: What is the maintenance procedure?

A: Routine wipe-down using IPA 70% or quaternary ammonium disinfectant. Panel surface is guaranteed for 5 years against peeling when used according to our cleaning chemical compatibility chart.

Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Echo Extraction Inc
Location NO.209 ZHUYUAN ROAD, HUQIU, CHINA SUZHOU INNOVATION PARK 215011.
Contact Person William

Request A Quote

Please check your email address.
Your message must be at least 20 characters.