Pure Sine Wave 1KW To 12KW Off Grid Inverter With Four Functions YM-HS
Price:
Negotiable
MOQ:
2 pieces
Delivery Time:
Negotiable
Brand:
Yima
Product Description
PRODUCT DESCRIPTION:
HS series products use high-efficiency, low-loss U-shaped transformers And complementary to the mains, support the generator start function,
Can support voltage dual output, users can set the charging mode according to the use environment, product integratedmanagement, with high conversion rate,It has the advantages of low powerconsumption and strong load capacity. It is the highest-end product in the currentindustrial frequency inverter.
PRODUCT FEATURES:
1. Contains four functions of mains bypass, mains charging, inverter,UPS, fully automatic switching
2. The efficiency is 3~5% higher than the ordinary power frequency series, and the self-consumption
is reduced by 30~50%
3. DIP switch selection: battery undervoltage point, input AC range, energysaving mode, priority mode
4. Remote communication interface RJ11/RJ45/RS232/485 remote control panel (optional)
5. Support PC software monitoring, support WIFI 4G module expansion to realize app cloud
monitoring (optional)
6. Pure sine wave output, input and output completely isolated design
7. Contains AC four-stage charging mode, and the charging current is automatically adjusted
8. It can be matched with commercial power, diesel engine power generationand other mixed
power supply
9. Can withstand 3 times the rated power start, excellent load capacity
10. LED display working status, LCD remote display operating parameters
11. Undervoltage/overvoltage/short circuit/overload/over temperature protection
12. Pure sine wave series inverters are suitable for renewable energy systems,
utilities, RVs,Marine and emergency applications.


HS Series parameter table
| Electrical Specifications | |||||||||||
| Model HS | 1KW | 2KW | 3KW | 4KW | 5KW | 6KW | 8KW | 10KW | 12KW | ||
| Inverter Output |
Continuous Output Power |
1000W | 2000W | 3000W | 4000W | 5000W | 6000W | 8000W | 10000W | 12000W | |
| Surge Rating(20ms) |
3KW | 6KW | 9KW | 12KW | 15KW | 18KW | 24KW | 30KW | 36KW | ||
| Output Waveform |
Pure Sine wave/Same as input(Bypass Mode) | ||||||||||
| Nominal Efficiency |
>88%(Peak) | ||||||||||
| Line Mode Efficiency |
>95% | ||||||||||
| Power Factor | 0.9-1.0 | ||||||||||
| Nominal Output Voltage rms |
100-110-120Vac / 220-230-240Vac | ||||||||||
| Output Voltage Regulation |
±10% RMS | ||||||||||
| Output Frequency |
50Hz ± 0.3Hz/60Hz ± 0.3Hz | ||||||||||
| Short Circuit Protection |
Yes( 1sec after fault ) | ||||||||||
| Typical transfer Time |
10ms(Max) | ||||||||||
| THD | < 10% | ||||||||||
| DC Input |
Nominal Input Voltage |
12.0Vdc / 24.0Vdc / 48.0Vdc |
24.0Vdc / 48.0Vdc | 48.0Vdc | |||||||
| Minimum Start Voltage |
10.0Vdc / 10.5Vdc for 12Vdc Mode |
*2 for 24Vdc, *4 for 48Vdc; | |||||||||
| Low Battery Alarm |
10.5Vdc / 11.0Vdc for 12Vdc Mode |
||||||||||
| Low Battery Trip | 10.0Vdc / 10.5Vdc for 12Vdc Mode |
||||||||||
| High Voltage Alarm |
16.0Vdc for 12Vdc Mode | ||||||||||
| Low Battery voltage recover |
15.5Vdc for 12Vdc Mode | ||||||||||
| Idle Consumption-Se arch Mode |
< 25 W when Power Saver On.(Refer to Table ) | ||||||||||
| Charger | Output Voltage | Depends on battery type (Refer to Table 2.5.2) | |||||||||
| Charger Breaker Rating |
10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||
| Max Charge Power Rate |
1/3 Rating Power (Refer to Table 2.5.3) | ||||||||||
| Battery Initial Voltage for Start |
10-15.7Vdc for 12Vdc Mode |
*2 for 24Vdc, *4 for 48Vdc; | |||||||||
| Over Charge Protection S.D. |
15.7Vdc for 12Vdc Mode | ||||||||||
| BTS | Battery Temperature Sensor (Optional) |
Yes(Refer to the table ) Variances in Charging Voltage & S.D Voltage Base on the Battery Temperature. |
|||||||||
| Bypass & Protection |
Input Voltage Waveform |
Sine wave (Grid or Generator) | |||||||||
| Nominal Voltage | 100-110-120Vac / 220-230-240Vac | ||||||||||
| Max Input AC Voltage |
150VAC For 120Vac LV Mode ;300VAC For 230Vac HV Mode; | ||||||||||
| Nominal Input Frequency |
50Hz or 60Hz | ||||||||||
| Low Freq Trip | 47±0.3Hz for 50Hz, 57±0.3Hz for 60Hz | ||||||||||
| High Freq Trip | 55±0.3Hz for 50Hz, 65±0.3Hz for 60Hz | ||||||||||
| Overload protection (SMPS load) |
Circuit Breaker | ||||||||||
| Output Short circuit protection |
Circuit Breaker | ||||||||||
| Bypass breaker rating |
10A | 20A | 30A | 40A | 40A | 40A | 50A | 80A | 80A | ||
| Transfer switch rating |
30Amp for UL & TUV | 40Amp for UL | 80Amp for UL | ||||||||
| Bypass without battery connected |
Yes (Optional) | ||||||||||
| Max bypass current |
30Amp | 40Amp | 80Amp | ||||||||
| Mechanical Specifications |
Mounting | Wall Mount | |||||||||
| Inverter Dimensions(L*W *H) |
340* 420* 200mm |
425*375*200mm | 560*420*235mm | 655*490*240mm | |||||||
| Inverter housing size (L*W*H) |
415* 440* 300mm |
500*495*300mm | 660*470*310mm | 720*470*290mm | |||||||
| Inverter Weight(Solar Chg)KG |
16 | 19.5 | 24 | 31.5 | 33.5 | 37.5 | 56.5 | 58.5 | 61.5 | ||
| Shipping Weight(Solar Chg)KG |
19 | 22 | 26.5 | 38 | 40 | 44 | 63.5 | 66 | 68.5 | ||
| Display | Status LEDs / Status LEDs+LCD | ||||||||||
| Standard Warranty |
2 Years (Optional) | ||||||||||
If the product model specification changes without notice
Similar Products
Related Videos
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Shenzhen Yima Power Supply Co., Ltd.
Location
Room 306, Building 2, Area A, Jinxiu Huacheng, Bantian Street, Longgang District, Shenzhen City
Contact Person
Steven Wang