37kw Vfd Inverter 3 Phase Air Compressor for Synchronous motor
37kw Vfd For Synchronous Motor Air Compressor Industry Specific Inverter
NZ200T-37GY-4-24V Inverter 37kW VFD For Air Compressor
Product Introduction:
1:Open loop vector control, VIF control
2:Overload capacity is 60s for 150% of rate current,3s for 180% of rate current.
3: High performance; environmental adaptationSimple structure; Compact size; Easy installEconomic vector control inverter,high torque output, motor runs smoothly when heavy loading.
4:Instantaneous stop doesn't stop,reduce the rate of frequent fault alarm.
5:Protection function: Output phase loss protection,Over-current protection, Over-voltage protection,Overload protection, Over-heat protection etc.
6:The terminal design is simple to install, specially designed for air compressor; Equipped with ZONCN self-developed HMI controller, the effect is better.
Product technical specification:
| Item | NZ200T |
| Control Mode |
Sensorless flux vector control(SFVC) Voltage/Frequency (V/F) Control |
| Maximum frequency | Vector control:0-320Hz V/F control:0-3200Hz |
| Carrier frequency |
1kHz~16kHz The carrier frequency is automatically adjusted based on the load features. |
| Input frequency resolution |
Digital setting:0.01Hz Analog setting: Maximum frequency 0.025% |
| Start torque |
G: Type:0.5Hz/150%(SVC) P: Type:0.5Hz/100% |
| Speed range | 1:100(SVC) |
| Speed stability accuracy | ±0.5%(SVC) |
| Overload capacity |
G Type:60s for 150% of the rated current, 3s for 180% of the rated current. P Type:60s for 120% of the rated current, 3s for 150% of the rated current. |
| Torque boost | Auto-boost ; Customized boost:0.1%~30.0% |
| VF curve | Straight-line VF curve; Multi-point VF curve; N-power VF curve(1.2-power,1.4-power,1.6-power,1.8-power, 2-power) |
| VF separation | 2 types: complete separation;half separation |
| Ramp Mode | Straight-line ramp;S-curve ramp;Four groups of acceleration/deceleration time:0~6500.0s |
| Simple PLC, Multiple preset speeds | It implements up to 16 speeds via the simple PLC function or combination of terminal states |
| Auto voltage regulation(AVR) | It can keep constant output voltage automatically when the mains voltage changes |
| Rapid current limit | It helps to avoid frequent over current faults of the AC drive. |
| Torque limit and control | It can limit the torque automatically and prevent frequent over-current tripping during the running process. |
| Onboard PID | It realizes process-controlled closed loop control system easily |
| Rapid current limit | It helps to avoid frequent over current faults of the AC drive. |
| JOG control |
JOG frequency range: 0.00–50.00 Hz JOG acceleration/deceleration time: 0.0–6500.0s |
| DC braking | DC braking frequency:0.00Hz to maximum frequency Braking time:0.0-100.0s Braking action current value:0.0%-100.0% |
| Instantaneous blackout doesn’t stop | The load feedback energy compensates the voltage reduction so that the AC drive can continue to run for a short time. |
| Timing control | Timing range:0.0Min~6500.0Min |
| Communication | RS485 |
| Run instruction channel | Keyboard given, control terminal given, serial communication port given. It can be switched in a variety of ways. |
| Frequency source | 10 kinds: digital given, analog voltage given, analog current given, pulse given, serial port given. It can be switched in a variety of ways. |
| Auxiliary frequency source | 10 auxiliary frequency sources. It can flexibly realize auxiliary frequency fine-tuning and frequency synthesis. |
| Input terminals |
6 digital input terminals, one of which supports up to 100 kHz high-speed pulse input (S3 optional). 2 analog input terminal, one of which only supports 0-10v voltage input(FIV) and the other supports 0-10 voltage input or 4-20 mA current input(FIC). |
| Output terminals |
1 digital output terminal(MO1) 1 relay output terminal(RA,RB,RC) 1 analog output terminal :that supports 0-20 mA current output or 0-10v voltage output(FOV) |
| Remark | X terminal is NPN type by default. If PNP type is required, contact customer service for customization. |
| LED display | Not removable. More than 45kw is acceptable. |
| Keystroke locking and function selection | Realize partial or full lock of keys, and define the scope of action of some keys to prevent false touch |
| Multiple protection modes | Motor short-circuit detection at power-on, output phase loss protection, over-current protection, over-voltage protection, under voltage protection, overheat protection and overload protection. |
Product model specification:
| Type | Input voltage | Rated output power(KW) | Rated input current(A) | Rated output current (A) | Motor power ( KW) |
| NZ200T-0R4G-2 |
AC 220V
|
0.4 | 5.4 | 2.5 | 0.4 |
| NZ200T-0R75G-2 | 0.75 | 7.2 | 5.0 | 0.75 | |
| NZ200T-1R5G-2 | 1.5 | 10.0 | 7.0 | 1.5 | |
| NZ200T-2R2G-2 | 2.2 | 16 | 11 | 2.2 | |
| NZ200T-3R7G-2 | 3.7 | 24 | 16.5 | 3.7 | |
| NZ200T-0R4G-4 |
AC 380V
|
0.4 | 3.4 | 1.2 | 0.4 |
| NZ200T-0R75G-4 | 0.75 | 3.8 | 2.5 | 0.75 | |
| NZ200T-1R5G-4 | 1.5 | 5.0 | 3.7 | 1.5 | |
| NZ200T-2R2G-4 | 2.2 | 5.8 | 5.0 | 2.2 | |
| NZ200T-3R7G/5R5P-4 | 3.7/5.5 | 10/15 | 9/13 | 3.7/5.5 | |
| NZ200T-5R5G/7R5P-4 | 5.5/7.5 | 15/20 | 13/27 | 5.5/7.5 | |
| NZ200T-7R5G/11P-4 | 7.5/11 | 20/26 | 17/25 | 7.5/11 | |
| NZ200T-11G/15P-4 | 11/15 | 26/35 | 25/32 | 11/15 | |
| NZ200T-15G/18.5P-4 | 15/18.5 | 35/38 | 32/37 | 15/18.5 | |
| NZ200T-18.5G/22P-4 | 18.5/22 | 38/46 | 37/45 | 18.5/22 | |
| NZ200T-22G/30P-4 | 22/30 | 46/62 | 45/60 | 22/30 | |
| NZ200T-30G/37P-4 | 30/37 | 62/76 | 60/75 | 30/37 | |
| NZ200T-37G/45P-4 | 37/45 | 76/90 | 75/90 | 37/45 | |
| NZ200T-45G/55P-4 | 45/55 | 90/105 | 90/110 | 45/55 | |
| NZ200T-55G-4 | 55 | 105 | 110 | 55 | |
| NZ200T-75P-4 | 75 | 140 | 150 | 75 | |
| NZ200T-75G/90P-4 | 75/90 | 140/160 | 150/176 | 75/90 | |
| NZ200T-90G/110P-4 | 90/110 | 160/210 | 176/210 | 90/110 | |
| NZ200T-110G/132P-4 | 110/132 | 210/240 | 210/253 | 110/132 | |
| NZ200T-132G/160P-4 | 132/160 | 240/290 | 253/300 | 132/160 | |
| NZ200T-160G/185P-4 | 160/185 | 290/330 | 300/340 | 160/185 | |
| NZ200T-185G/200P-4 | 185/200 | 330/370 | 340/380 | 185/200 | |
| NZ200T-200G/220P-4 | 200/220 | 370/410 | 380/420 | 200/220 | |
| NZ200T-220G/250P-4 | 220/250 | 410/460 | 420/470 | 220/250 | |
| NZ200T-250G/280P-4 | 250/280 | 460/500 | 470/520 | 250/280 | |
| NZ200T-280G/315P-4 | 280/315 | 500/580 | 520/600 | 280/315 | |
| NZ200T-315G/350P-4 | 315/350 | 580/620 | 600/640 | 315/350 | |
| NZ200T-350G/400P-4 | 350/400 | 620/670 | 640/690 | 350/400 | |
| NZ200T-400G/450P-4 | 400/450 | 670/790 | 690/790 | 400/450 |
HMI controller:
Product application:
FAQ:
Q1:What is your MOQ?
A: 1 pc
Q2:What's your terms of payment?
A:T/T 100% before delivery.
Q3:What's your delivery time?
A:Generally within ten days after receiving full payment.
Q4:How can l get OEM/ODM order?
A:If your order quantity meets certain requirements, we are happy to customize it for you. We have cooperation with more than forty manufacturers.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.