Type SHD-GC 2kV Mining Reeling Trailing 3 AWG 3C Power Cable
Type SHD-GC 2kV Mining Reeling Trailing Power Cable: Engineered for Demanding Industrial Applications
The Feichun Type SHD-GC 2kV Mining Reeling Trailing Power Cable is a cutting-edge solution tailored for heavy-duty mining and industrial operations.

This comprehensive guide explores the cable's technical specifications, engineering features, primary applications, compliance standards, and installation guidelines to help readers understand its performance and reliability.
Product Specification Overview
The Type SHD-GC Power Cable is built to meet the demands of mining equipment, stackers and reclaimers, and other heavy machinery. Its robust construction and advanced materials deliver superior performance. Below is an overview of its key specifications.
| Specification | Details |
|---|---|
| Cable Type | SHD-GC Mining Reeling Trailing Power Cable |
| Voltage Rating | 2000 Volts (2kV) |
| Number of Conductors | 3 Conductors + Ground + Ground Check |
| Conductor Size | 3 AWG, 259 strands |
| Insulation Material | Ethylene Propylene Rubber (EPR) |
| Insulation Thickness | 1.8 mm (0.070 inches) |
| Outside Diameter | 38.3 mm (1.51 inches) |
| Net Weight | 0.76 kg/m (1.68 lbs per ft) |
| Current Capacity | 140 AMPS |
Conductor and Insulation Specifications
1. Ground Conductor
| Attribute | Details |
|---|---|
| AWG Size | 7 AWG |
| Material | Bare Copper |
| Purpose | Provides safety by carrying fault currents |
2. Ground Check Conductor
| Attribute | Details |
|---|---|
| AWG Size | 10 AWG |
| Insulation Material | Polypropylene |
| Purpose | Monitors the cable's grounding system for integrity |
3. Insulation and Temperature Ratings
The Type SHD-GC Cable incorporates EPR insulation, offering exceptional resistance to heat, moisture, and chemicals.
| Attribute | Details |
|---|---|
| Insulation Temperature Rating | 90°C Continuous Operation |
| Voltage Ratings | Available in 2kV, 5kV, 8kV, 15kV, and 25kV configurations |
| Material Benefits | Superior dielectric strength, long service life |
Key Engineering Features
1. Advanced Material Technology
| Material | Feature |
|---|---|
| Ethylene Propylene Rubber (EPR) | Exceptional dielectric strength, moisture, and heat resistance |
| Chlorinated Polyethylene (CPE) | Outer jacket material, resistant to UV, chemicals, and abrasion |
These materials enable the cable to withstand extreme conditions, ensuring long-term reliability and safety.
2. 3+3 Construction Design
The three-conductor design includes three power conductors and three ancillary components (ground and ground check). This configuration ensures:
- Mechanical stability during high-flex applications.
- Improved durability under constant reeling and trailing.
- Optimized performance for dynamic industrial environments.
3. Integrated Fiber Optics (Optional)
For advanced monitoring and control, the cable can support fiber optic cores, enabling simultaneous power and data transmission.
Application Domains
1. Primary Industrial Applications
The Type SHD-GC Power Cable is ideal for mining and industrial equipment that require high power delivery under tough conditions.
| Application | Examples |
|---|---|
| Mining Equipment | Continuous miners, shuttle cars, loaders |
| Material Handling Machines | Stackers, reclaimers, and conveyors |
| Port Operations | Electrified rubber-tired gantry cranes, ship unloaders |
| Heavy Mobile Equipment | Excavators, bulldozers, and haul trucks |
2. Extreme Environmental Conditions
The cable is specially designed for underground mining, surface operations, and areas with chemical exposure, abrasive surfaces, or extreme temperatures.
Performance Advantages
1. Exceptional Mechanical Resilience
- Abrasion Resistance: Protects against cuts and scrapes.
- Puncture Resistance: Withstands mechanical shocks.
- Tear Resistance: Ideal for dynamic reeling applications.
2. High Reliability in Tough Environments
The SHD-GC Cable maintains consistent performance in:
- Wet or dry conditions.
- High-heat zones.
- Cold climates.
Compliance and Certification
The Type SHD-GC Cable adheres to stringent international safety and performance standards:
| Standard | Compliance |
|---|---|
| MSHA Regulations | Approved for mining safety |
| IEEE Guidelines | Meets power cable specifications |
| IEC Standards | Ensures compatibility with global industrial systems |
| NFPA Requirements | Fire-retardant and flame-tested |
- TYPE SHD-GC - 2000 VOLTS Round
| NO. OF COND. | COND. SIZE (AWG/ | COND. STRAND | NOMINAL INSULATION THICKNESS | GRD. COND. SIZE (AWG) | GRD-CHECK COND. SIZE (AWG) | NOMINAL JACKET THICKNESS | NOMINAL CABLE 0.D. | NET WEIGHT |
| kg/ km | ||||||||
| mm | mm | mm | ||||||
| 3 | 6 | 133 | 1.8 | 10 | 10 | 3.9 | 32.8 | 1682 |
| 3 | 4 | 259 | 1.8 | 8 | 10 | 3.9 | 35.6 | 2173 |
| 3 | 3 | 259 | 1.8 | 7 | 10 | 4.3 | 38.3 | 2500 |
| 3 | 2 | 259 | 1.8 | 6 | 8 | 4.3 | 40.4 | 2961 |
| 3 | 1 | 259 | 2 | 5 | 8 | 4.8 | 44.7 | 3549 |
| 3 | 1/0 | 259 | 2 | 4 | 8 | 4.8 | 47.2 | 4115 |
| 3 | 2/0 | 329 | 2 | 3 | 8 | 5.2 | 50.8 | 4844 |
| 3 | 3/0 | 413 | 2 | 2 | 8 | 5.2 | 54.1 | 5789 |
| 3 | 4/0 | 532 | 2 | 1 | 8 | 5.6 | 58.7 | 7024 |
| 3 | 250 | 608 | 2.4 | 1/0 | 6 | 5.6 | 63.8 | 8125 |
| 3 | 300 | 741 | 2.4 | 1/0 | 6 | 6 | 68.1 | 9517 |
| 3 | 350 | 851 | 2.4 | 2/0 | 6 | 6.4 | 71.4 | 10834 |
| 3 | 500 | 1221 | 2.4 | 4/0 | 6 | 6.7 | 81 | 14614 |
Installation and Maintenance Considerations
1. Best Practices for Installation
Proper handling during installation ensures optimal performance and longevity.
| Guideline | Recommendation |
|---|---|
| Cable Handling | Avoid sharp bends; maintain minimum bend radius |
| Environmental Suitability | Designed for underground and surface applications |
| Protection | Use guards against sharp objects |
2. Maintenance and Inspection
Regular inspections ensure the cable's integrity and reliability.
| Inspection Type | Frequency |
|---|---|
| Visual Checks | Monthly |
| Electrical Tests | Semi-annually |
| Mechanical Integrity Tests | Annually |
Technical Risk Mitigation
The Type SHD-GC Cable addresses common risks in industrial and mining applications:
| Risk | Mitigation |
|---|---|
| Electrical Faults | Robust ground conductors and electrical isolation |
| Mechanical Damage | Durable CPE jacket with abrasion resistance |
| Fire Hazards | Flame-retardant properties |
Conclusion
The Feichun Type SHD-GC 2kV Mining Reeling Trailing Power Cable is a premium solution for critical power transmission in the most challenging industrial environments. Its advanced engineering and robust materials ensure unmatched reliability, mechanical strength, and long-term safety.
Why Choose Feichun SHD-GC Cable?
- Durable Materials: EPR insulation and CPE jacket for extreme conditions.
- High Performance: Consistent power delivery under dynamic loads.
- Global Compliance: Certified to meet rigorous safety standards.
Technical Support and Consultation
For detailed technical assistance or custom configurations, contact the Feichun Technical Support Team today.
- Custom Solutions: Voltage ratings, cable lengths, and additional features.
- Expert Guidance: Installation and maintenance best practices.
Empower your operations with Feichun SHD-GC Power Cables — designed for excellence.


Note: This is just part of the standard parameters of our products. Please contact our Engineer if you need more. And the information contained within this webpage is for guidance only and is subject to change without notice or liability. All dimensions and specifications are nominal and are subject to normal manufacturing tolerances. All pictures shown are for illustration purposes only. The actual product may vary. All the information is provided in good faith and is believed to be correct at the time of publication.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.