Zhongshan Hobun Electric & Gas Appliances Co., Ltd.
                                                                                                           
Verified Supplier
29 Years
Since 1997
Menu

Loading Quantity 40HQ 780 PCS Direct Vent Gas Water Heater 10L Volume Optimized for Commercial Providing and Water Heating

Price Negotiable
Price: 100 USD
MOQ: 100 Pcs
Delivery Time: 30-45 Days
Brand: HAOBANG
Product Description

Loading Quantity 40HQ 780 PCS Direct Vent Gas Water Heater 10L Volume Optimized for Commercial Providing and Water Heating



Product Description


Guest reviews are unforgiving about hot water. A single mention of an inconsistent shower can outweigh a dozen compliments about breakfast, and unlike most operational problems, water temperature complaints cannot be resolved with an apology at checkout. Our 10L Instant Constant Temperature Gas Water Heater removes this category of risk from a small hospitality operation. Guests arriving at irregular hours find hot water immediately available without any pre-heating cycle, back-to-back check-ins encounter no depleted reservoir, and the ±0.5°C precision of the proportional gas valve means the shower behaves identically at eight in the morning and eleven at night. A 21kW burner working through an oxygen-free copper exchanger provides the capacity to make that consistency real rather than aspirational.



Specifications


At 530 by 330 by 143 millimetres in a plate iron enclosure, the unit installs discreetly in service areas away from guest circulation. IPX2 protection suits the humid conditions of hospitality utility rooms, and efficiency above 93 percent controls the operating cost line that matters in thin-margin accommodation businesses. Natural gas at 2000 pascals enters via a G1/2 inch inlet with a 2.06 cubic metre per hour consumption rate, yielding 11 litres per minute at a 25-degree rise or 2.64 gallons per minute. The 0.02 to 0.8 pascal working pressure range handles the variable supply conditions of older converted properties, temperature adjusts across 35 to 80 degrees Celsius by touch panel, and 220V forced exhaust venting accepts 50, 60, or 90 millimetre flues.



Technical Parameters


Voltage 220V
Origin Guangdong, China
Airflow Stability Control Constant Air Combustion
Heat Exchanger Oxygen Free Copper
Exhaust Forced Exhaust
Flue Dimension 50MM / 60MM / 90MM
Gas Pressure NG(2000Pa)
Loading Quantity 40HQ 780 PCS
Dimensions Varies By Model
Control Method Touch Panel


Installation Scenarios & Installation Precautions


Boutique homestays, small guesthouses, converted townhouse B&Bs, and holiday cottages with two to three bathrooms form the target application. Position the unit in a staff-access utility area rather than a guest-accessible space, both to prevent unauthorised temperature adjustment and to keep operating sound away from bedrooms. Verify the wall's load-bearing capacity, especially in heritage or converted structures where original construction was never designed for wall-hung appliances. Allow 200 millimetres above and 150 millimetres to either side, position the flue terminal 600 millimetres clear of any window or door — including guest room windows, which are easy to overlook in multi-storey conversions — and complete a documented gas leak test. Installation in sealed bathrooms, guest bedrooms, or unventilated stairwells is prohibited.



Features & Value Delivered to Global Buyers


Operational features include constant temperature output within ±0.5°C, flame failure protection, 176-degree Fahrenheit overheat protection, electronic ignition, and LED touch-panel control that staff can read at a glance during turnover. Three engineering decisions define its edge over competitors in hospitality service: an oxygen-free copper exchanger built for the higher duty cycle of guest accommodation, verified 93 percent efficiency that compounds across a full occupancy season, and 780 pieces per 40HQ container for operators expanding across multiple properties. OEM support covers silk-screen branding with the property identity, housing colours matched to the interior scheme, flue sizing, display variants, and protection modules. Each order includes a one-year warranty, one percent complimentary spare parts, and technical documentation.



Safety Boundaries & Long-Term Use Reminders


This unit is not designed for hotel-scale continuous demand beyond small guesthouse patterns, not suitable for installation in guest-accessible enclosed spaces, and not intended for use outside the specified gas pressure ranges without factory reconfiguration. Staff should be trained never to bypass any safety protection module, to keep the flue outlet unobstructed, and to know the emergency gas shutoff location. Because hospitality duty cycles exceed domestic patterns, shorten maintenance intervals accordingly: inspect the inlet filter every three months, arrange professional combustion chamber inspection annually before the peak season begins rather than at an arbitrary calendar date, and test flame failure protection at each seasonal changeover so that any fault surfaces during low occupancy rather than at full booking.


Get in Touch

Have questions about our products or want to discuss a custom order? Our team is ready to help you.

Company Zhongshan Hobun Electric & Gas Appliances Co., Ltd.
Location Floor 5th Bld. B, No. 6, Antai Road, Dongfeng Town, Zhongshan City, Guangdong Province
Contact Person Kevin

Request A Quote

Please check your email address.
Your message must be at least 20 characters.