Kitchen Balcony Flue Gas Water Heater Optional Color Black White Silver Compact Design Heating Solution for Commercial
Kitchen Balcony Flue Gas Water Heater Optional Color Black White Silver Compact Design Heating Solution for Commercial
Product Description
Seasonal workers need dependable washing facilities, but agricultural sites rarely offer the stable utilities found in urban housing. This 6L flue type instant gas water heater answers that operating reality with bottled-fuel compatibility, battery pulse ignition, and a compact flow rate suited to individual showers. It consumes fuel only while water moves, avoiding the standing losses of a tank kept warm throughout long shifts or empty periods between harvest seasons. The 12-kilowatt harmonica-shaped burner applies heat across an oxygen-free copper exchanger, supplying approximately 6 litres per minute at a 25-degree Celsius rise. A water-gas interlock initiates the sequence automatically, while rotary controls allow site managers to set a practical 30-to-55-degree outlet range. The appliance needs no connection to the local power grid because a DC 3V battery pack drives ignition. This makes it useful at farms, plantations, fisheries, and processing compounds where electricity may be limited but LPG distribution is available.
Specifications
A housing measuring 440 by 300 by 120 millimetres keeps the heater suitable for repeated installation in compact wash blocks. Rated heat input is 12 kilowatts and verified thermal efficiency is at least 84 percent. Under the defined 25-degree rise, nominal output reaches 6 litres per minute, appropriate for one outlet in operation. The water circuit accepts pressure from 0.02 to 0.8 megapascals and uses standard G1/2-inch inlet and outlet threads. Fuel variants are calibrated for LPG at 2800 pascals or natural gas at 2000 pascals through a matching G1/2-inch connection. DC 3V battery-powered pulse ignition lights a three-section burner, and a 90-millimetre chimney carries combustion products outdoors by natural draft. Temperature can be adjusted between 30 and 55 degrees Celsius, with heating and stabilisation each specified within 15 seconds under correct site conditions.
Technical Parameters
| Water Pressure | 0.02-0.8MPa |
| Heating Efficiency | ≥85% |
| Installation Type | Wall Mounted |
| Warranty | 1 Year |
| Color | Black / White / Silver |
| Chimney Size | 60mm |
| Installation Location | Kitchen / Balcony |
| Special Features | Digital Display |
| Valve | Solenoid Valve |
| Controller | Knob Control |
Installation Scenarios & Installation Precautions
Suitable locations include ventilated farm kitchens, purpose-built shower blocks, agricultural staff quarters, covered washing stations, and utility rooms attached to rural accommodation. The heater must never be mounted inside a sealed shower cubicle, bedroom, animal barn, stairwell, or store containing hay, feed, fuel, fertiliser, or other combustible products. Provide a permanent air opening through a louvre, window, or door grille, and take the 90-millimetre smoke pipe outdoors by a short, mainly vertical route. Verify that the wall supports the filled appliance, keep 200 millimetres clear above it and 150 millimetres on both sides, and protect the installation from livestock, machinery, and chemical spray. LPG cylinders should remain outdoors with the correct regulator. Before handover, test every joint with soap solution, confirm battery polarity, and display simple operating and emergency shutoff instructions in the workers’ main language.
Features & Value Delivered to Global Buyers
For workforce housing, useful value comes from repeatable installation and manageable upkeep. Low-water-pressure operation supports elevated tanks, dual ignition pins improve first-strike reliability, and the water-gas linkage prevents fuel admission without flow. Flame-loss shutdown, anti-dry protection, excess-temperature control, pressure protection, and a 20-minute limit supervise unattended or unfamiliar users. Housing colour, panel finish, labels, and operating graphics can be adapted for estate operators or regional distributors. Orders start at 100 pieces per model, sample evaluation is available before production, and normal lead time follows approval and deposit. The one-year warranty is reinforced with free consumable service parts so remote sites can restore a unit without replacing the whole appliance.
Safety Boundaries & Long-Term Use Reminders
This appliance is not designed for enclosed sleeping quarters, barns with airborne dust, exposed outdoor posts, or high-pressure wash systems. Never store LPG cylinders in the same occupied room, cover the heater with clothing, or disable a safety switch. Site supervisors should close the fuel valve when accommodation is vacant and investigate any yellow flame, delayed lighting, or unusual odour immediately. Replace batteries annually and keep spares in the maintenance store. Clean the inlet screen quarterly where bore or tank water carries sediment, inspect the flue for insects and nesting material before each worker intake, and drain the circuit when seasonal housing will stand unused through freezing weather.
Get in Touch