Water Pressure 00208MPa Gas Geyser Wall Mounted Industrial Grade Hot Water Heater Suitable for Various Business Settings
Water Pressure 00208MPa Gas Geyser Wall Mounted Industrial Grade Hot Water Heater Suitable for Various Business Settings
Product Description
A low purchase price loses its appeal when a minor field failure forces the distributor to replace an entire appliance. This 6L flue type instant gas water heater is structured around serviceability as well as first-sale performance. Knobs, battery boxes, pulse ignitors, thermostats, switches, and cartons are identifiable support items, allowing local partners to resolve ordinary wear or shipping damage without dismantling their inventory program. The core heating platform uses a 12-kilowatt harmonica-shaped burner and copper heat exchanger to supply approximately 6 litres per minute at a 25-degree Celsius rise. Automatic pulse ignition responds to water movement, and the DC 3V battery system avoids dependence on a wall socket. Its open-flue configuration and G1/2-inch connections follow familiar installation practice across many LPG and natural-gas markets. For an importer, the result is not merely another compact heater but a product line that can be stocked, explained, repaired, and reordered through a consistent after-sales structure.
Specifications
The common chassis measures 440 by 300 by 120 millimetres, reducing warehouse complexity across panel and branding variations. Rated heat input is 12 kilowatts and thermal efficiency is at least 84 percent. At a 25-degree Celsius rise, nominal water output reaches 6 litres per minute; the adjustment range is 30 to 55 degrees Celsius. The water system operates between 0.02 and 0.8 megapascals. LPG units are calibrated to 2800 pascals and natural-gas units to 2000 pascals, so destination fuel must be confirmed before production. Ignition runs from DC 3V batteries and uses a pulse controller with two electrodes. Water inlet, hot outlet, and gas inlet use G1/2-inch threads, while the chimney connection is 90 millimetres. Coated steel, stainless-steel, and glass panel configurations can share the same core service architecture.
Technical Parameters
| Heating Efficiency | ≥85% |
| Ignition Type | Electronic Ignition |
| Water Pressure | 0.02-0.8MPa |
| Exhaust System | Flue Exhaust |
| Valve | Solenoid Valve |
| Chimney Size | 60mm |
| Gas Pressure | NG(2000Pa) / LPG(2800Pa) |
| Controller | Knob Control |
| Installation Type | Wall Mounted |
| Installation Location | Kitchen / Balcony |
Installation Scenarios & Installation Precautions
This distributor-focused platform suits dealer networks serving household kitchens, ventilated balconies, farm accommodation, small guesthouses, and renovation projects. Installers should receive a common checklist covering permanent room ventilation, outdoor chimney termination, fuel-pressure verification, leak testing, and minimum service clearances. Each unit needs 200 millimetres above and 150 millimetres at the sides, a load-bearing wall, and a mainly vertical 90-millimetre flue route. It must not be installed in a sealed bathroom, bedroom, stairwell, enclosed cupboard, or space storing flammable material. Distributor training should also distinguish LPG from natural-gas units visually so technicians do not connect the wrong calibration. Battery polarity, water flow, ignition timing, flame colour, and safety shutdowns should be documented on the commissioning record.
Features & Value Delivered to Global Buyers
For a distributor building a durable category, the practical advantage is a defined service ecosystem. Standardised consumables reduce repair time, free spare-part allocations establish an initial warranty stock, and the one-year coverage gives dealers a clear customer promise. Low-pressure startup, dual ignition pins, flame-failure shutdown, anti-dry protection, overheat protection, excess-pressure control, seasonal adjustment, and a 20-minute timer provide a coherent sales story without relying on inflated claims. OEM options include colour, panel material, logo printing, display selection, manuals, and carton presentation. The standard MOQ is 100 pieces per model, samples require 5 to 20 days depending on configuration, and production normally takes 30 to 35 days after confirmation and deposit.
Safety Boundaries & Long-Term Use Reminders
Service parts must be fitted only by trained technicians and matched to the correct model and fuel calibration. A replacement component cannot correct poor ventilation, an obstructed chimney, excessive pressure, or an incorrect regulator. The heater is not intended for enclosed bathrooms, direct rain, or continuous industrial operation. Dealers should never instruct users to bypass the flame sensor or water-gas linkage to keep a faulty unit running. Maintain traceable spare-part records, replace batteries yearly, clean inlet filters according to water quality, and inspect flues annually. Units showing repeated ignition failure, yellow flame, heat damage, or corrosion should be withdrawn from service until professionally assessed.