Automatic Pulse Ignition Flue Gas Water Heater Corrosion Resistance Instant Hot Water Heater Continuous Hot Water Supply
Automatic Pulse Ignition Flue Gas Water Heater Corrosion Resistance Instant Hot Water Heater Continuous Hot Water Supply
Product Description
A distributor can cover several retail segments without carrying several unrelated water-heater platforms. This 6L flue type instant gas water heater pairs one serviceable internal architecture with white-coated metal, stainless-steel, or glass panel options, then reinforces the range with defined replacement components. An entry model can emphasise affordability, a stainless version can target practical wet kitchens, and a glass-fronted edition can occupy the design tier, yet technicians work with the same 12-kilowatt burner, DC 3V pulse system, and G1/2-inch interfaces. The copper heat exchanger delivers approximately 6 litres per minute at a 25-degree Celsius rise, suitable for one residential shower or wash outlet. Water-triggered operation means the appliance burns fuel only during use, and adjustable controls cover 30 to 55 degrees. This common-platform approach reduces training, spare-part, and warranty complexity while allowing the visible product range to remain broad enough for different channels and customer budgets.
Specifications
Every fascia version uses the same compact 440-by-300-by-120-millimetre installation footprint. The rated heat input is 12 kilowatts and documented efficiency is no lower than 84 percent. Nominal delivery reaches 6 litres per minute at the defined 25-degree rise, with heating initiated within 15 seconds. Water pressure may range from 0.02 to 0.8 megapascals. LPG and natural-gas variants are separately prepared for 2800 and 2000 pascals. The automatic pulse ignitor uses DC 3V battery power and two electrodes to light a three-section harmonica burner. Water inlet, outlet, and fuel entry use G1/2-inch threads, and natural exhaust connects to a 90-millimetre smoke pipe. Depending on the selected front, buyers can pair adjustable knobs with LED or LCD indication and specify a colour treatment compatible with the panel material.
Technical Parameters
| Ignition Type | Automatic Pulse Ignition |
| Temperature Control | Digital Display |
| Heat Exchange Material | Copper |
| Connection Size | G1/2" (Gas/Inlet/Outlet) |
| Heating Efficiency | ≥85% |
| Water Pressure | 0.02-0.8MPa |
| Volume | 6 Liter |
| Color | All Color Will Be Available |
| Function | Low Water Pressure Start |
| Keywords | Instant Hot Water Heater, Instant Gas Water Heater, Natural Gas Water Heater, Tankless Gas Water Heater |
Installation Scenarios & Installation Precautions
The range can serve apartment projects, wet-kitchen retailers, boutique homestays, renovation showrooms, and regional dealers offering several price tiers. All exterior versions share identical installation boundaries: a well-ventilated kitchen, service balcony, or covered utility corridor; an exterior 90-millimetre flue; and permanent replacement air. No panel option is suitable for a sealed bathroom, sleeping room, stairwell, closed cabinet, or direct rain. Confirm that the wall carries the operating load, reserve 200 millimetres above and 150 millimetres at each side, and protect glass or coated surfaces from nearby cooking flame and harsh chemicals. Verify the exact gas version, conduct a soap-solution leak test, and record panel and internal model references so future spare parts are correctly matched.
Features & Value Delivered to Global Buyers
The range strategy combines visual differentiation with common technical support. Buyers can define fascia material, colour, silk-screen identity, display style, carton artwork, and control labels while retaining low-pressure startup, dual ignition, water-gas interlock, flame-loss shutdown, anti-dry protection, overheat and pressure controls, seasonal selection, and the 20-minute timer. Free service allocations can include knobs, battery boxes, pulse ignitors, thermostats, switches, and cartons. MOQ starts at 100 pieces per model, samples take 5 to 20 days depending on decoration, and volume production normally requires 30 to 35 days after confirmation and deposit. Warranty coverage is one year.
Safety Boundaries & Long-Term Use Reminders
Visual variants must not be represented as technically different unless their purchase specifications actually differ. The appliance is unsuitable for sealed or poorly ventilated spaces, outdoor rain exposure, or continuous industrial demand. Keep all panel types unobstructed and never drape merchandise or cloth over showroom or installed units. Use non-abrasive cleaning methods appropriate to each surface. Distributors should separate LPG and natural-gas stock clearly, preserve batch records, and train technicians on shared service components. Replace batteries annually, inspect chimney terminals, clean inlet filters, and test protective shutdown functions as part of scheduled maintenance.
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.