INDUSTRIAL SCIENTIFIC Tango TX1 T40 II Single Gas Detector RATTLER Tango TX1 T40 II GB PRO T40 PRO
Technical Specifications
Display:
Segmented Liquid Crystal Display (LCD)
Key:
2 buttons
Material
Top of the product: Polycarbonate and rubber coated protective shell
Bottom of product: Conductive polycarbonate
Alert:
Visual alarm: Three frequency LED flashing lights (two red lights, one blue light);
Sound alarm: 100 decibels within a 10cm (3.04 ") range; Vibration alarm
Size:
99 x 51 x 35 mm
Weight:
126.0 g
Working temperature:
-40°C ~ +50°C
Working humidity:
10%~95% non condensing (continuous)
Protection level:
IP66 ; IP67
Sensor:
Electrochemical sensor technology
Sensor measurement range:
Carbon monoxide (CO): 0 to 1000.0 ppm, with a resolution of 1 ppm
Carbon monoxide (CO) low hydrogen interference: 0 to 1000ppm, resolution of 1ppm
Hydrogen sulfide (H2S): 0.0 to 500.0 ppm, with a resolution of 0.1 ppm
Nitrogen dioxide (NO2): 0.0 to 20.0ppm, with an accuracy of 0.1ppm
Nitrogen dioxide (NO2): 0.0 to 50.0ppm, with an accuracy of 0.1ppm
Nitrogen dioxide (NO2): 0.0 to 150.0ppm, with an accuracy of 0.1ppm
Sulfur dioxide (SO2): 0.0 to 20.0ppm, with an accuracy of 0.1ppm
Sulfur dioxide (SO2): 0.0 to 100.0ppm, with an accuracy of 0.1ppm
Sulfur dioxide (SO2): 0.0 to 150.0ppm, with an accuracy of 0.1ppm
Hydrogen cyanide (HCN): 0.0 to 30.0ppm, with an accuracy of 0.1ppm
Ammonia (NH3): 0 to 500ppm, with an accuracy of 1ppm
Battery/operating time (ambient temperature environment):
3.6V disposable lithium thionyl chloride (Li-SOCl2) battery, 1.5AH, 2/3AA, replaceable, non rechargeable, with a standby time of up to 2 years
Sampling method:
Diffusion/pumping suction
authentication:
ATEX ,IECEx ,UL (C-US) ,CSA ,MSHA ,INMETRO
China Metrology, China Explosion proof
Detectable gas
CO,H2S,SO2,NO2,HCN,NH3
Carbon monoxide, hydrogen sulfide, sulfur dioxide, nitrogen dioxide, hydrogen cyanide, ammonia
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.