Portatle and Desktop Chilli Tester Scoville Meter Chili Spiciness Tester WANYI801 WANYI802 WANYI101 Casco C-450
Features:
- 8-channel fiber optical path synchronous detection,avoid signal attenuation, accurate measurement
- Measure the absorbance synchronously, with fast speed,short consumption, and avoid interference;
- Single / double wavelength measurement, which can be freely selected according to the experimental project and sample state requirements;
- Automatic center positioning function, obtain the colorimetric light diameter,reduce the impact;
- Standard with 405nm, 450nm, 492nm, 630nm, can expand 8 wavelengths;
- Start-up self-check and abnormal alarm function to ensure that the instrument is in good working condition;
- The function of the shock plate can be adjusted so that the liquid in the hole is fully mixed;
- Combined functions, one board can detect single / double sample multiple items simultaneously;
- Various calibration and calculation methods, to meet the requirements of different test items;
- 100 item programs are randomly stored and edit tests arbitrarily;
- It can store 1,000,000 test results, with the function of query and print reports;
- Visualized arrangement plate free place of blank, standard, quality control and sample position;
- At the same time with the screen to display the absorbance and results of the whole board, at a glance;
Specification:
1.Detection channel: 8 Fiber channels
2.Microplate specification: support 48 / 96 holes, compatible with "U",flat plate holes
3.Plate read mode: progress and continuous board reading mode
4.Read the plate wavelength range: 330-1100nm
5.Central wavelength: ± 1nm
6.Detection speed: <5 seconds / 96 wells (single wavelength continuous determination)
7.Filter: Standard with 405nm, 450nm, 492nm, 630nm, and scalable up to 8 wavelengths
8.Resolution: 0.001 Abs
9.Absorbance: 0-4 Abs
10.Absorbance Repeatability: CV <0.1%
11.Absorbance Accuracy: ± 0.008A
12.Channel Difference: 0.015A
13.Linear correlation coefficient: R2 > 99.9%
14.Plate speed: low speed, medium speed, high speed
15.Plate time: 0-60s, increasing by 1 second
16.Calibration method: multi-point calibration, single-point / multi-point calibration, linear regression, exponential regression, logarithmic regression, power regression,factor calculation and other standard curve calculation methods
17.Quality Control mode: LJ method, immediate method and WESTGARD multi-rule quality control function
18.Results output: standard thermal printer, can also be connected to the PC for data transmission
19.Light source: quartz halogen lamp
20.Power supply: 220-250V, 50 / 60Hz
21.Size: 497mm*327mm*169mm
22.Working environment: Temperature 5-35 ° C; relative humidity 15% -85%
23.Weight: 8.0 KG
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.