| Number of inputs and outputs |
Number of digital outputs: 2 |
| Measuring range |
|
| Process connection |
threaded connection G 1/4 |
| Installation length EL [mm] |
50 |
Application
| System |
gold-plated contacts |
| Measuring element |
1 x Pt 1000; (to DIN EN 60751, class A) |
| Media |
liquids and gases |
| Medium temperature [°C] |
-40...145 |
| Pressure rating [bar] |
400 |
Electrical data
| Operating voltage [V] |
9.6...32 DC; (cULus - Class 2 source required) |
| Current consumption [mA] |
< 30 |
| Protection class |
III |
| Reverse polarity protection |
yes |
| Power-on delay time [s] |
0.5 |
Inputs / outputs
| Number of inputs and outputs |
Number of digital outputs: 2 |
Outputs
| Total number of outputs |
2 |
| Output signal |
switching signal |
| Electrical design |
PNP |
| Number of digital outputs |
2 |
| Output function |
complementary |
| Max. voltage drop switching output DC [V] |
2 |
| Permanent current rating of switching output DC [mA] |
500 |
| Short-circuit protection |
yes |
| Type of short-circuit protection |
yes (non-latching) |
| Overload protection |
yes |
Measuring/setting range
| Measuring range |
|
| Set point SP |
|
| Reset point rP |
|
Accuracy / deviations
| Temperature drift per 10 K [K] |
0.1 **) |
| Repeatability [K] |
± 0,1 |
| Setting accuracy [K] |
± 3 |
Reaction times
| Dynamic response T05 / T09 [s] |
1 / 3; (according to DIN EN 60751) |
Software / programming
| Adjustment of the switch point |
setting rings |
Operating conditions
| Ambient temperature [°C] |
-40...80 |
| Note on ambient temperature |
| at medium temperature: < 80 °C |
| -40...50 °C |
| at medium temperature: < 145 °C |
|
| Storage temperature [°C] |
-40...100 |
| Protection |
IP 67 |
Tests / approvals
| EMC |
| DIN EN 61000-4-2 ESD |
4 kV CD / 8 kV AD |
| EN 61000-4-3 HF radiated |
10 V/m |
| DIN EN 61000-4-4 Burst |
2 kV |
| EN 61000-4-6 HF conducted |
10 V |
|
| Shock resistance |
| DIN IEC 68-2-27 |
50 g (11 ms) |
|
| Vibration resistance |
| DIN EN 60068-2-6 |
20 g (10...2000 Hz) |
|
| MTTF [years] |
643.1 |
| UL approval |
|
Mechanical data
| Weight [g] |
104.5 |
| Material |
stainless steel (1.4404 / 316L); PC; PBT; FKM |
| Materials (wetted parts) |
stainless steel (1.4404 / 316L); FKM |
| Tightening torque [Nm] |
35 |
| Process connection |
threaded connection G 1/4 |
| Probe diameter [mm] |
6 |
| Installation length EL [mm] |
50 |
Displays / operating elements
| Display |
| Power |
LED, green |
| Switching status |
LED, yellow |
|
Remarks
| Remarks |
| **) In case of deviation from the reference condition 25 °C |
| The values for accuracy apply to flowing water. |
|
| Pack quantity |
1 pcs. |
Electrical connection
| Connection |
Connector: 1 x M12; coding: A; Contacts: gold-plated |