SV vortex flowmeters with display for water based media SV4610 SVN12XXXIRKG/US-100
Price:
$200-$300
MOQ:
1pc
Delivery Time:
3-5days
Brand:
IFM
Product Description

Product characteristics
| Number of inputs and outputs | Number of digital outputs: 2 | ||
|---|---|---|---|
| Measuring range |
|
||
| Process connection | threaded connection 1/2" NPT DN8 |
Application
| System | gold-plated contacts | |
|---|---|---|
| Application | for industrial applications | |
| Media | water; glycol solutions; Coolants | |
| Medium temperature [°F] | 14...194 | |
| Pressure rating [bar] | 12 | |
| Pressure rating [psi] | 174 | |
| Note on pressure rating |
|
|
| MAWP (for applications according to CRN) [bar] | 3.9 |
Electrical data
| Operating voltage [V] | 18...30 DC |
|---|---|
| Current consumption [mA] | < 30 |
| Min. insulation resistance [MΩ] | 100; (500 V DC) |
| Protection class | III |
| Reverse polarity protection | yes |
| Power-on delay time [s] | < 3 |
Inputs / outputs
| Number of inputs and outputs | Number of digital outputs: 2 |
|---|
Outputs
| Total number of outputs | 2 |
|---|---|
| Output signal | switching signal; frequency signal; IO-Link; (configurable) |
| Electrical design | PNP/NPN |
| Number of digital outputs | 2 |
| Output function | normally open / closed; (configurable) |
| Max. voltage drop switching output DC [V] | 2.5 |
| Permanent current rating of switching output DC [mA] | 100 |
| Short-circuit protection | yes |
| Overload protection | yes |
Measuring/setting range
| Measuring range |
|
||
|---|---|---|---|
| Display range |
|
||
| Resolution |
|
||
| Set point SP |
|
||
| Reset point rP |
|
||
| Frequency end point, FEP |
|
||
| In steps of |
|
||
| Frequency at the end point FRP [Hz] | 100...1000 | ||
| Measuring dynamics | 1:20 |
Temperature monitoring
| Measuring range [°F] | 14...194 |
|---|---|
| Display range [°F] | -22...230 |
| Resolution [°F] | 1 |
| Set point SP [°F] | 16...194 |
| Reset point rP [°F] | 14...192 |
| In steps of [°F] | 1 |
| Frequency start point, FSP [°F] | 14...158 |
| Frequency end point, FEP [°F] | 50...194 |
| Frequency at the end point FRP [Hz] | 100...1000 |
Accuracy / deviations
Flow monitoring
| Accuracy (in the measuring range) | ± 2 % MEW; (water) |
|---|---|
| Repeatability | ± 0,5 % MEW |
Temperature monitoring
| Accuracy [K] | ± 1 |
|---|
Reaction times
Flow monitoring
| Response time [s] | 1; (dAP = 0) |
|---|---|
| Damping process value dAP [s] | 0...5 |
Temperature monitoring
| Dynamic response T05 / T09 [s] | T09 = 6 |
|---|
Software / programming
| Parameter setting options | hysteresis / window; normally open / closed; switching logic; Frequency output; switch-on/switch-off delay; Damping; Display unit |
|---|
Interfaces
| Communication interface | IO-Link | ||||
|---|---|---|---|---|---|
| Transmission type | COM2 (38,4 kBaud) | ||||
| IO-Link revision | 1.1 | ||||
| SDCI standard | IEC 61131-9 | ||||
| Profiles | Smart Sensor: Process Data Variable; Device Identification, Device Diagnosis | ||||
| SIO mode | yes | ||||
| Required master port class | A | ||||
| Process data analog | 2 | ||||
| Process data binary | 2 | ||||
| Min. process cycle time [ms] | 3 | ||||
| Supported DeviceIDs |
|
Operating conditions
| Ambient temperature [°F] | 32...140 | ||
|---|---|---|---|
| Note on ambient temperature |
|
||
| Storage temperature [°F] | -4...176 | ||
| Protection | IP 65; IP 67 |
Tests / approvals
| EMC |
|
||||
|---|---|---|---|---|---|
| Shock resistance |
|
||||
| Vibration resistance |
|
||||
| MTTF [years] | 342 | ||||
| UL approval |
|
||||
| Pressure equipment directive | sound engineering practice; can be used for group 2 fluids; group 1 fluids on request |
Mechanical data
| Weight [g] | 481.5 |
|---|---|
| Material | stainless steel (1.4404 / 316L); PC; PBT+PC-GF30; PPS; TPE-U |
| Materials (wetted parts) | stainless steel (1.4404 / 316L); ETFE; PA 6T; PPS; FKM |
| Tightening torque [Nm] | 30 |
| Process connection | threaded connection 1/2" NPT DN8 |
Remarks
| Remarks |
|
||
|---|---|---|---|
| Pack quantity | 1 pcs. |
Electrical connection
| Connection | Connector: 1 x M12; coding: A; Contacts: gold-plated |
|---|
Diagrams and graphs
| Pressure loss |
|
|---|
| pressure rating (bar) |
|---|
Similar Products
Get in Touch
Have questions about our products or want to discuss a custom order? Our team is ready to help you.
Company
Xiamen ZhiCheng Automation Technology Co., Ltd
Location
903-3, building F02, phase III Software Park, Jimei district, Xiamen city,CHINA (361000)
Contact Person
Andy