YC-1891D Single-phase Energy Meter Calibration Equipment with 120A Current Range and 288V Voltage Output
Price:
negotiate rates
MOQ:
1
Delivery Time:
6~8weeks
Brand:
GENY
Product Description
YC-1891D Series Single-phase Energy Meter Calibration Equipment
The YC-1891D series single-phase energy meter calibration equipment is designed for comprehensive testing and verification of various single-phase energy meters. This professional-grade equipment serves electric power departments, energy meter manufacturers, metrology and quality inspection departments, and industrial enterprises.
Technical Specifications
| Parameter | Specification |
|---|---|
| Power Supply | AC220V±10%, 50Hz±2Hz |
| Output Voltage Range | 24V to 288V |
| Output Voltage Power | 1000VA (Maximum) |
| Output Current Range | 1mA to 120A (230A Maximum) |
| Output Current Power | 2000VA (Maximum) |
| Continuous Current | 100A |
| Voltage/Current Resolution | 0.01% |
| Voltage/Current Stability | 0.02%/120s |
| Frequency Range | 45Hz to 65Hz |
| Phase Adjustment Range | 0° to 360° |
Standard Testing Capabilities
- Active power, reactive power, active energy, and reactive energy measurement
- Start-up and creep testing with automatic calibration
- Basic error, average error, standard deviation, and 24-hour variation analysis
- Voltage, frequency, harmonic (2nd to 21st order), and phase sequence influence tests
- Simultaneous current measurement on same meter rack
- Non-disconnection testing for current and voltage circuits
- Open-circuit current and short-circuit voltage protection
- Optical head collection and flipping functionality
- Electric and manual operation modes
- Computer software for automatic error data processing and storage
- Barcode input support and comprehensive data management
- Configurable from 3 to 60 meter positions
Advanced Testing Features
- Bidirectional active and reactive power error testing
- SW-5D precision time base source for daily timing error measurement
- Communication testing and broadcast time synchronization
- Verification of constants via pulse count, time, and start/stop energy methods
- Time-of-use switching, demand cycle, and demand value error testing
- Counter value and counter combination error analysis
- Optional power consumption testing
- Optional tilt influence testing
- Optional prepaid energy meter testing functionality
Related Videos