Stationary Meter Test Bench MTS with 3×1000VA Voltage Output and 3×1500VA Current Output for IEC-Compliant Meter Calibration
Price:
negotiate rates
MOQ:
1
Delivery Time:
6~8weeks
Brand:
GENY
Product Description
Stationary Meter Test Bench MTS - Advanced Calibration System
Core Testing Capabilities
- Smart Meter Testing with RS232 parallel communication ports
- Terminal calibration for accurate test bench verification
- Landis+Gyr three-phase energy meter compatibility
- Reference standard meter precision testing
- IEC standard compliance for precision testing
- Comprehensive performance testing including no-load, starting current, and repeatability of error tests
- Meter clock frequency precision testing
- Maximum demand testing capabilities
- Influence quantity testing for voltage, frequency, reverse phase sequence, and voltage unbalance
- Harmonic impact testing for voltage and current circuits per IEC standards
- Subharmonic and odd harmonic testing compliance
Customized Automation Features
- Automated wiring connection setups
- Automatic short circuit protection at all stations
- Landis+Gyr QCD quick connection device
- PC software for ESAM testing
Technical Specifications
Power Supply Requirements
| Voltage | 3 × 220V ±10% |
| Frequency | 50 / 60Hz ± 2Hz |
| Power Capacity | >6k VA |
| Ambient Temperature | -10°C to +40°C |
| Relative Humidity | 35% to 85% |
Power Source Performance
| Voltage Output | |
| Test Voltage Output (Phase-Neutral) | 3 × (24V - 300V) |
| Power of Voltage Output | 3 × 1000VA |
| Resolution | Better than 0.01% of full scale value |
| Setting Accuracy | Better than 0.05% at final range value |
| Stability | Better than 0.005%/h (integration time 150 s) |
| Load Regulation (0-max. load) | Better than 0.01% |
| Distortion Factor | Better than 0.3% for linear resistance load |
| Harmonics | 2nd - 21st free programmable |
| Current Output | |
| Test Current Output | 3 × (0.3mA - 20A) |
| Power of Current Output | 3 × 1500VA |
| Resolution | Better than 0.01% of full scale value |
| Setting Accuracy | Better than 0.05% at final range value |
| Stability | Better than 0.005%/h (integration time 150 s) |
| Load Regulation (0-max. load) | Better than 0.01% |
| Distortion Factor | Better than 0.3% for linear resistance load |
| Harmonics | 2nd - 21st free programmable |
| Additional Parameters | |
| Phase Angle Range | 0 - 360° |
| Phase Angle Resolution | 0.01° |
| Phase Angle Setting Accuracy | 0.1° |
| Frequency Range | 45Hz - 65Hz |
| Frequency Resolution | 0.01Hz |
Additional Information
For comprehensive technical documentation and detailed specifications, please visit our official website: www.genymetertestequipment.com